Event Notification Report for March 01, 2006
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
02/28/2006 - 03/01/2006
EVENT NUMBERS
42378423794238842391
Power Reactor
Event Number: 42378
Facility: INDIAN POINT
Region: 1 State: NY
Unit: [2] [] []
RX Type: [2] W-4-LP,[3] W-4-LP
NRC Notified By: STEPHEN PRUSSMAN
HQ OPS Officer: MIKE RIPLEY
Region: 1 State: NY
Unit: [2] [] []
RX Type: [2] W-4-LP,[3] W-4-LP
NRC Notified By: STEPHEN PRUSSMAN
HQ OPS Officer: MIKE RIPLEY
Notification Date: 03/01/2006
Notification Time: 18:13 [ET]
Event Date: 03/01/2006
Event Time: 14:35 [EST]
Last Update Date: 03/01/2006
Notification Time: 18:13 [ET]
Event Date: 03/01/2006
Event Time: 14:35 [EST]
Last Update Date: 03/01/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
CHRISTOPHER CAHILL (R1)
CHRISTOPHER CAHILL (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | M/R | Y | 100 | Power Operation | 0 | Hot Standby |
MANUAL REACTOR TRIP AS A RESULT OF DROPPED CONTROL RODS
"On March 1, 2006, at 1435 hours, the Reactor Protection System was manually actuated while at 100 percent power upon indication of 12 dropped rods. All safety systems actuated as required and safety equipment operated as expected. There were eight control rods that did not indicate full insertion. One control rod had a bad rod bottom light bulb and the other seven control rods require calibration to indicate full insertion. Auxiliary Feedwater started as expected. The Emergency Diesel Generators did not start as offsite power remained available and stable. No primary or secondary relief valves lifted. The plant is in Hot Standby at normal temperature and pressure with residual heat removal using auxiliary feedwater and normal heat removal through the condenser via steam dumps. There was no radiation released.
"An investigation revealed that a manual disconnect switch for power control cabinet 1AC was open and scaffold work was being performed in the area. Cabinet 1AC is the power supply for the 12 dropped rods. The event is still under investigation and a post trip review is being conducted."
The licensee notified the State and the NRC Resident Inspector.
"On March 1, 2006, at 1435 hours, the Reactor Protection System was manually actuated while at 100 percent power upon indication of 12 dropped rods. All safety systems actuated as required and safety equipment operated as expected. There were eight control rods that did not indicate full insertion. One control rod had a bad rod bottom light bulb and the other seven control rods require calibration to indicate full insertion. Auxiliary Feedwater started as expected. The Emergency Diesel Generators did not start as offsite power remained available and stable. No primary or secondary relief valves lifted. The plant is in Hot Standby at normal temperature and pressure with residual heat removal using auxiliary feedwater and normal heat removal through the condenser via steam dumps. There was no radiation released.
"An investigation revealed that a manual disconnect switch for power control cabinet 1AC was open and scaffold work was being performed in the area. Cabinet 1AC is the power supply for the 12 dropped rods. The event is still under investigation and a post trip review is being conducted."
The licensee notified the State and the NRC Resident Inspector.
Power Reactor
Event Number: 42379
Facility: SUSQUEHANNA
Region: 1 State: PA
Unit: [1] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: RICH KLINEFELTER
HQ OPS Officer: MIKE RIPLEY
Region: 1 State: PA
Unit: [1] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: RICH KLINEFELTER
HQ OPS Officer: MIKE RIPLEY
Notification Date: 03/01/2006
Notification Time: 22:22 [ET]
Event Date: 03/01/2006
Event Time: 21:27 [EST]
Last Update Date: 03/02/2006
Notification Time: 22:22 [ET]
Event Date: 03/01/2006
Event Time: 21:27 [EST]
Last Update Date: 03/02/2006
Emergency Class: ALERT
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED 50.72(b)(2)(xi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED 50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
CHRISTOPHER CAHILL (R1)
MELVYN LEACH (IRD)
JOSE CALVO (NRR)
JIM DYER (NRR)
SAM COLLINS (RA)
CHRISTOPHER CAHILL (R1)
MELVYN LEACH (IRD)
JOSE CALVO (NRR)
JIM DYER (NRR)
SAM COLLINS (RA)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 93 | Power Operation | 93 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
ALERT DECLARED DUE TO HALON DISCHARGE IN SECURITY CONTROL CENTER
"At 21:27 on March 1, 2006, a Susquehanna security officer evacuated the security control center and notified the control room of a fire alarm and actuation of the Halon fire suppression system. The actuation of this system resulted in a potential atmosphere immediately dangerous to life and health [IDLH] of personnel in a plant vital area. The fire brigade responded to the event, donning respirators to enter the building, but saw no visible smoke or flames. As a result of an IDLH atmosphere in a plant vital area, Susquehanna entered the emergency plan at the Alert level."
The NRC Resident Inspector was informed and responded to the site. The licensee notified state, local and other government agencies. The licensee plans on issuing a press release.
Notified DHS (Hill), FEMA (Liggett), DOE (Bailey), EPA (National Response Center, Baumgartner), HHS (Riggs), and USDA (D. Timmons).
* * * UPDATE AT 0530 EST ON 3/2/06 FROM RICH KLINEFELTER TO S. SANDIN * * *
The licensee terminated the Alert 0433 EST based on the following:
Habitability was restored to the security control center by
1. Stopping the Halon discharge
2. Ventilating the affected area
3. Restoring access
4. Isolating Halon sources in the adjacent area to prevent a recurrence and,
5. Posting Fire Watches.
The licensee informed State/local agencies and the on-site NRC Resident Inspector.
Notified Region I (Perry), NRR EO (Calvo), IRD (Leach), DHS (Hill), FEMA (Liggett), DOE (Pauley), EPA (National Response Center, McCrossen), HHS (H. Peagler), and USDA (D. Timmons).
"At 21:27 on March 1, 2006, a Susquehanna security officer evacuated the security control center and notified the control room of a fire alarm and actuation of the Halon fire suppression system. The actuation of this system resulted in a potential atmosphere immediately dangerous to life and health [IDLH] of personnel in a plant vital area. The fire brigade responded to the event, donning respirators to enter the building, but saw no visible smoke or flames. As a result of an IDLH atmosphere in a plant vital area, Susquehanna entered the emergency plan at the Alert level."
The NRC Resident Inspector was informed and responded to the site. The licensee notified state, local and other government agencies. The licensee plans on issuing a press release.
Notified DHS (Hill), FEMA (Liggett), DOE (Bailey), EPA (National Response Center, Baumgartner), HHS (Riggs), and USDA (D. Timmons).
* * * UPDATE AT 0530 EST ON 3/2/06 FROM RICH KLINEFELTER TO S. SANDIN * * *
The licensee terminated the Alert 0433 EST based on the following:
Habitability was restored to the security control center by
1. Stopping the Halon discharge
2. Ventilating the affected area
3. Restoring access
4. Isolating Halon sources in the adjacent area to prevent a recurrence and,
5. Posting Fire Watches.
The licensee informed State/local agencies and the on-site NRC Resident Inspector.
Notified Region I (Perry), NRR EO (Calvo), IRD (Leach), DHS (Hill), FEMA (Liggett), DOE (Pauley), EPA (National Response Center, McCrossen), HHS (H. Peagler), and USDA (D. Timmons).
General Information or Other
Event Number: 42388
Rep Org: OK DEQ RAD MANAGEMENT
Licensee: VIA CHRISTI CANCER CENTER
Region: 4
City: PONCA CITY State: OK
County:
License #: OK-14046-02
Agreement: Y
Docket:
NRC Notified By: M. BRODERICK
HQ OPS Officer: JOHN MacKINNON
Licensee: VIA CHRISTI CANCER CENTER
Region: 4
City: PONCA CITY State: OK
County:
License #: OK-14046-02
Agreement: Y
Docket:
NRC Notified By: M. BRODERICK
HQ OPS Officer: JOHN MacKINNON
Notification Date: 03/06/2006
Notification Time: 10:30 [ET]
Event Date: 03/01/2006
Event Time: 12:00 [CST]
Last Update Date: 03/06/2006
Notification Time: 10:30 [ET]
Event Date: 03/01/2006
Event Time: 12:00 [CST]
Last Update Date: 03/06/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
CHUCK CAIN (R4)
MICHELE BURGESS (NMSS)
CHUCK CAIN (R4)
MICHELE BURGESS (NMSS)
INCORRECT DOSE GIVEN TO PROSTATE PATIENT
The State provided the following information via facsimile:
"The medical physicist for the Via Christi Cancer Center reported that a medical event had occurred the day before. A patient was treated for prostate cancer with I-125 seeds. An activity of 0.4 air kerma units per seed was ordered. The seeds were received with an activity of 0.4 millicuries per seed. The difference in activity units was not detected until after the surgery was completed. The patient received a total dose of 12,850 centigray rather than the prescribed 10,000 centigray; a 28% difference. The radiation oncologist has determined that this larger dose should not cause any untoward harm to the patient. The referring urologist and the patient have been notified of the dose discrepancy. As corrective action, the licensee plans to introduce a new form to be used as part of the procedure followed during permanent implant preparation. This form will be used to record seed activity, including the units, used in treatment planning, listed on the shipping form as well as the seed activity observed at the time of implant."
OK Item # - OK060004
The State provided the following information via facsimile:
"The medical physicist for the Via Christi Cancer Center reported that a medical event had occurred the day before. A patient was treated for prostate cancer with I-125 seeds. An activity of 0.4 air kerma units per seed was ordered. The seeds were received with an activity of 0.4 millicuries per seed. The difference in activity units was not detected until after the surgery was completed. The patient received a total dose of 12,850 centigray rather than the prescribed 10,000 centigray; a 28% difference. The radiation oncologist has determined that this larger dose should not cause any untoward harm to the patient. The referring urologist and the patient have been notified of the dose discrepancy. As corrective action, the licensee plans to introduce a new form to be used as part of the procedure followed during permanent implant preparation. This form will be used to record seed activity, including the units, used in treatment planning, listed on the shipping form as well as the seed activity observed at the time of implant."
OK Item # - OK060004
General Information or Other
Event Number: 42391
Rep Org: COLORADO DEPT OF HEALTH
Licensee: COTTER CORP URANIUM MILL
Region: 4
City: CANYON CITY State: CO
County:
License #: 369-01
Agreement: Y
Docket:
NRC Notified By: PHILIP EGIDI
HQ OPS Officer: MARK ABRAMOVITZ
Licensee: COTTER CORP URANIUM MILL
Region: 4
City: CANYON CITY State: CO
County:
License #: 369-01
Agreement: Y
Docket:
NRC Notified By: PHILIP EGIDI
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 03/06/2006
Notification Time: 20:00 [ET]
Event Date: 03/01/2006
Event Time: 01:00 [MST]
Last Update Date: 03/06/2006
Notification Time: 20:00 [ET]
Event Date: 03/01/2006
Event Time: 01:00 [MST]
Last Update Date: 03/06/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
CHUCK CAIN (R4)
SCOTT FLANDERS (NMSS)
MELVYN LEACH (IRD)
CHUCK CAIN (R4)
SCOTT FLANDERS (NMSS)
MELVYN LEACH (IRD)
YELLOW CAKE DRUM EVACUATED INTO ENCLOSED ROOM
At approximately 14:00 on 2/28/2006, an employee noticed that a drum of soluble yellow cake had a bulging lid and bottom cap. At 01:00 on 3/1/06, an employee in full protective clothing entered the calciner to release the lid. When the lid was released, approximately half of the barrel's contents evacuated the barrel. Some of the yellow cake went under the employee's hood.
The employee will undergo testing 3/7/06.
At approximately 14:00 on 2/28/2006, an employee noticed that a drum of soluble yellow cake had a bulging lid and bottom cap. At 01:00 on 3/1/06, an employee in full protective clothing entered the calciner to release the lid. When the lid was released, approximately half of the barrel's contents evacuated the barrel. Some of the yellow cake went under the employee's hood.
The employee will undergo testing 3/7/06.