42260

Power Reactor
Event Number: 42260
Facility: QUAD CITIES
Region: 3     State: IL
Unit: [1] [] []
RX Type: [1] GE-3,[2] GE-3
NRC Notified By: KEVIN O'SHEA
HQ OPS Officer: JOHN KNOKE
Notification Date: 01/15/2006
Notification Time: 12:36 [ET]
Event Date: 01/15/2006
Event Time: 11:04 [CST]
Last Update Date: 01/15/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - PLANT S/D REQD BY TS
Person (Organization):
KENNETH O'BRIEN (R3)
MICHAEL MAYFIELD (NRR)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 85 Power Operation 85 Power Operation
Event Text
TS SHUTDOWN DUE TO ELECTROMATIC RELIEF VALVES (ERVS) DECLARED INOPERABLE

"At 1014 hours on January 15, 2006, the four Unit 1 Electromatic Relief Valves (ERVs) were declared inoperable due to concerns related to the ERV actuators. These operability concerns originated from inspections and testing performed on the Unit 2 ERVs which indicate evidence of mechanical interference issues that could prevent proper ERV operation (note that Unit 2 was shutdown on January 14, 2006 to perform ERV actuator inspections). In accordance with Technical Specification 3.4.3, Condition B, 3.5.1 Condition H, and 3.6.1.6 Condition B, Unit 1 commenced a shutdown on January 15, 2006 at 1104 hours.

"This notification is being made in accordance with 10 CFR 50.72(b)(2)(i) as commencement of any nuclear plant shutdown required by the plant's Technical Specifications.

"During the upcoming Unit 1 outage, actuator inspections and ERV testing is planned to confirm the operational ability of the ERVs. Note that the Unit 1 Target Rock Relief Valve and the Main Steam Safety Valves are operable and available to support reactor overpressure protection."

The plant is conducting a normal shutdown per Tech Spec requirements. At 1600 CST the unit will going off line and by 2400 CST the plant is expected to be in Mode 4 (Cold Shutdown).

The licensee notified the NRC Resident Inspector.