Other Nuclear Material
Event Number: 42247
Rep Org: AK STEEL CORPORATION
Licensee: AK STEEL CORPORATION
Region: 3
City: ROCKPORT   State: IN
County:
License #:
Agreement: N
Docket:
NRC Notified By: STEVE CUSTER
HQ OPS Officer: STEVE SANDIN
Notification Date: 01/10/2006
Notification Time: 17:15 [ET]
Event Date: 01/09/2006
Event Time: 11:30 [CST]
Last Update Date: 01/11/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
30.50(b)(2) - SAFETY EQUIPMENT FAILURE
Person (Organization):
KENNETH O'BRIEN (R3)
C.W. (BILL) REAMER (NMSS)
Event Text
FAILURE OF SHUTTER TO CLOSE ON FIXED DENSITY GAUGE USED TO MEASURE STEEL THICKNESS

At 1130 hours on 01/09, the air cylinder on a gate operating the shutter for a fixed gauge failed to close. The gauge, a SenTek device, model not identified, is generally licensed and contains a 1000 mCi Am-241 source. The device was removed from service and heavy steel plate was positioned to shield the source. Additionally, the affected area was isolated and posted. No unmonitored personnel exposures occurred. A SenTek technician arrived onsite and corrected the malfunctioning shutter as of 0900 hours 01/10/06.

* * * UPDATE 1340 EST ON 1/11/06 FROM STEVE CUSTER TO S. SANDIN * * *

Further investigation determined that the fixed gauge is a model THAM2 manufactured by ABB AccuRay. The initial report is required per 10 CFR 30.50(b)(2). AK Steel will be submitting a followup written report within 30 days. Notified R3DO(O'Brien) and NMSS (Morell).


Power Reactor
Event Number: 42245
Facility: MILLSTONE
Region: 1     State: CT
Unit: [] [2] []
RX Type: [1] GE-3,[2] CE,[3] W-4-LP
NRC Notified By: ROBERT MALONEY
HQ OPS Officer: JEFF ROTTON
Notification Date: 01/09/2006
Notification Time: 17:09 [ET]
Event Date: 01/09/2006
Event Time: 04:55 [EST]
Last Update Date: 01/09/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(A) - POT UNABLE TO SAFE SD
Person (Organization):
RICHARD CONTE (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
LOSS OF CHARGING SYSTEM IMPACT ON SAFE SHUTDOWN CAPABILITY

At 0455 EST, the control room received a Plant Process computer alarm for the 'C' Charging pump and entered TS 3.0.3. TS 3.0.3 was entered due to both ECCS trains becoming inoperable due to the loss of the charging subsystem safety function. The 'A' charging pump (backup) was started at 0458 and had sufficient flow for only several minutes. The control room then attempted to start the 'B' charging pump (standby) at 0459 with no success. At 0500 Charging and Letdown was secured and at 0501, operators identified a potential 'B' charging pump pulse dampener bladder failure and entered AOP 2568 for RCS leakage. The 'B' Charging pump suction and discharge were isolated at 0510 and at 0544 the 'C' charging pump was vented and restored to service. The licensee exited TS 3.0.3 at 0554 and entered TS 3.5.2 A since 'B' train of ECCS was restored to operability. The licensee suspects that the nitrogen from the bladder on the discharge of the pump leaked through the 'B' charging pump to the common charging pump suction header and caused gas intrusion to the running 'C" charging pump and to the common suction header for the standby charging pumps. TS 3.5.2 Bases does not credit the charging system for Design Basis Accident (DBA) mitigation, however the charging system is credited for two beyond DBA events - ATWS and Complete Loss of Secondary Heat Sink.

At 1343 EST, the control room received a Charging low flow alarm with the 'C' charging pump in service. Charging and Letdown were secured and the licensee entered TS 3.0.3 at 1344. At 1459 the licensee completed the fill and vent of the 'C' charging pump and started the pump at 1514 and placed Charging and Letdown into service. The licensee is performing an engineering evaluation to keep the 'C' charging pump running and an Operability Determination must be completed prior to declaring the 'C' charging pump operable. The licensee continues to troubleshoot the 'A' charging pump to restore to operability. Once the 'C' charging pump is declared operable, the licensee will exit TS 3.0.3

The licensee notified the NRC Resident Inspector, and both state and local emergency response organizations.


General Information or Other
Event Number: 42303
Rep Org: LOUISIANA RADIATION PROTECTION DIV
Licensee: OWENSBY & KRITIKOS
Region: 4
City: GRETNA   State: LA
County:
License #: LA-2234-L01
Agreement: Y
Docket:
NRC Notified By: MIKE HENRY
HQ OPS Officer: GERRY WAIG
Notification Date: 02/02/2006
Notification Time: 12:19 [ET]
Event Date: 01/09/2006
Event Time: 00:00 [CST]
Last Update Date: 02/02/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
MIKE RUNYAN (R4)
GREG MORELL (NMSS)
Event Text
AGREEMENT STATE - PERSONNEL OVEREXPOSURE

The following was received from the State of Louisiana, Department of Environmental Quality, via facsimile:

"Event description: Owensby & Kritikos reported on January 19, 2006 that [deleted] exceeded the 5000 mrem exposure for the year 2005. [Deleted] received a yearly dose of 5117 mrem for the year 2005. [Deleted] is an industrial radiographer. As corrective action, the Radiation Safety Officer discussed the importance of ALARA concepts and the use of survey meters, dosimeters, and film badges."

Louisiana Event Report ID Number: LA060001.


General Information or Other
Event Number: 42319
Rep Org: WA DIVISION OF RADIATION PROTECTION
Licensee: MULTICARE MEDICAL CENTER
Region: 4
City: TACOMA   State: WA
County:
License #: WN-M017-1
Agreement: Y
Docket:
NRC Notified By: ARDEN SCROGGS
HQ OPS Officer: BILL HUFFMAN
Notification Date: 02/07/2006
Notification Time: 19:10 [ET]
Event Date: 01/09/2006
Event Time: 00:00 [PST]
Last Update Date: 02/07/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
ANTHONY GODY (R4)
LARRY CAMPER (NMSS)
TAS (E-MAIL)
Event Text
AGREEMENT STATE - SOURCE DISPOSAL RECORDS UNAVAILABLE

The State provided the following information via email:

"On 09 January 2006 Washington Office of Radiation Protection received written notification from Multicare that Multicare could not account for transfer / disposal of 12 (twelve) Gadolinium-153 radioactive sealed sources (260 microcuries, 9.6 Megabecquerels total activity on 09 January 2006). The notification was in response to an Item of Noncompliance issued to Multicare for incomplete transfer / disposal records. The licensee believes that the sources were properly disposed of around December 2003, but incomplete records cannot confirm this. Complete records for similar sources confirm proper disposal of similar sources around similar time frame. [The Washington Office of Radiation Protection] investigation continues."

Washington State Report #WA-06-003

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.

This source is not amongst those sources or devices identified by the IAEA Code of Conduct for the Safety & Security of Radioactive Sources to be of concern from a radiological standpoint. Therefore is it being categorized as a less than Category 3 source


Hospital
Event Number: 42353
Rep Org: MIDSTATE MEDICAL CENTER
Licensee: MIDSTATE MEDICAL CENTER
Region: 1
City: MERIDEN   State: CT
County:
License #: 06-05686-02
Agreement: N
Docket:
NRC Notified By: EILEEN NOBLE
HQ OPS Officer: BILL HUFFMAN
Notification Date: 02/21/2006
Notification Time: 17:00 [ET]
Event Date: 01/09/2006
Event Time: 00:00 [EST]
Last Update Date: 02/21/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
PAMELA HENDERSON (R1)
SCOTT MOORE (NMSS)
Event Text
LOSS OF GADOLINIUM-153 SOURCE

The licensee reported that a gadolinium-153 source (1 Curie Amersham Source #2837LN assayed 08/21/91) cannot be accounted for. The source was installed in a bone mineral density device (LUNAR DP-3) that was retired in 1994. The licensee became aware of this issue when NRC Region 1 inquired into the status of the source during a license renewal application review. Based on the investigation to date, the licensee determined that the bone mineral density device was likely disposed of as scrap metal. The disposition of the source is uncertain. There is no indication that the source was removed from the device and placed into storage. There are also no records that it was returned to Amersham (or its predecessor company). The licensee stated that Amersham did not have source reclamation records dating to the mid-1990s.

The licensee noted that the Midstate Medical Center has undergone significant management change since the 1994 including the RSO position. The licensee does not have the same name (previously Veterans Memorial Medical Center) and is not even located in the same building as it was when the source containing bone mineral density device was retired. The current strength of the source based on decay would be 0.2 microCuries.

The licensee's investigation is continuing. NRC Region 1 (W. Lee and R. McKinley) have been interacting with the licensee on this event.

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.