Event Notification Report for March 22, 2005

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
03/21/2005 - 03/22/2005

EVENT NUMBERS
415114151241513

Power Reactor
Event Number: 41511
Facility: TURKEY POINT
Region: 2     State: FL
Unit: [] [4] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: PAUL REIMERS
HQ OPS Officer: BILL HUFFMAN
Notification Date: 03/22/2005
Notification Time: 04:21 [ET]
Event Date: 03/22/2005
Event Time: 03:47 [EST]
Last Update Date: 03/22/2005
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
STEPHEN CAHILL (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
4 M/R Y 100 Power Operation 0 Hot Standby
Event Text
REACTOR MANUALLY TRIPPED FOLLOWING LOSS OF MAIN FEED PUMP

The licensee provided the following information via fax (licensee text in quotes)

"The 4A SGFP [Steam Generator Feed Pump] tripped, initiating a Turbine Runback. Operators manually inserted a Reactor Trip at 15% Steam Generator level. The reactor tripped and all control rods inserted. Auxiliary Feedwater automatically initiated as expected. All systems operated as expected except the 4A SGFP discharge MOV which has no [position] indication [in the main control room and is being] investigated."

Decay heat is being removed by atmospheric steam dumps. The licensee will notify the NRC Resident Inspector.


Power Reactor
Event Number: 41512
Facility: NINE MILE POINT
Region: 1     State: NY
Unit: [1] [] []
RX Type: [1] GE-2,[2] GE-5
NRC Notified By: BRETT BOISMENU
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 03/22/2005
Notification Time: 08:10 [ET]
Event Date: 03/22/2005
Event Time: 00:00 [EST]
Last Update Date: 03/22/2005
Emergency Class: NON EMERGENCY
10 CFR Section:
26.73 - FITNESS FOR DUTY
Person (Organization):
MOHAMED SHANBAKY (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
FOR CAUSE FITNESS FOR DUTY TEST FAILURE

A contract supervisor had a confirmed positive for alcohol during a "for-cause" fitness for duty test. The contractor's site access was denied, the contractor was escorted off site and provided a ride home. Contact the Headquarters Operations Officer for additional details.

The NRC Resident will be notified by the site.


Power Reactor
Event Number: 41513
Facility: SEABROOK
Region: 1     State: NH
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: MATHEW ARSENAULT
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 03/22/2005
Notification Time: 12:25 [ET]
Event Date: 03/22/2005
Event Time: 11:02 [EST]
Last Update Date: 03/22/2005
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - PLANT S/D REQD BY TS
Person (Organization):
MOHAMED SHANBAKY (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 61 Power Operation
Event Text
PLANT SHUTTING DOWN TO MODE 3 FROM 100% POWER DUE TO A REACTOR TRIP BREAKER BEING INOPERABLE.

A plant shutdown to mode 3( 0% power) was started at 1102 on 3/22/05. The shutdown was required per T.S. 3.3-1 Table 3.3-1, item 19, action 9. Reactor trip breaker "A" is inoperable. T.S.3.3.1, Table 3.3-1 item 19, action requires a shutdown to mode 3 within 6 hours. Plant must be in mode 3 by 1622 EST on 3-22-05. They are currently troubleshooting on the reactor trip breaker.


The NRC Resident Inspector was notified.