Event Notification Report for January 05, 2005
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
01/04/2005 - 01/05/2005
General Information or Other
Event Number: 41318
Rep Org: WHITING CORPORATION
Licensee: WHITING CORPORATION
Region: 3
City: MONEE State: IL
County:
License #:
Agreement: Y
Docket:
NRC Notified By: MARK KWASNY
HQ OPS Officer: JOHN KNOKE
Licensee: WHITING CORPORATION
Region: 3
City: MONEE State: IL
County:
License #:
Agreement: Y
Docket:
NRC Notified By: MARK KWASNY
HQ OPS Officer: JOHN KNOKE
Notification Date: 01/07/2005
Notification Time: 14:47 [ET]
Event Date: 01/05/2005
Event Time: 00:00 [CST]
Last Update Date: 01/07/2005
Notification Time: 14:47 [ET]
Event Date: 01/05/2005
Event Time: 00:00 [CST]
Last Update Date: 01/07/2005
Emergency Class: NON EMERGENCY
10 CFR Section:
21.21 - UNSPECIFIED PARAGRAPH
10 CFR Section:
21.21 - UNSPECIFIED PARAGRAPH
Person (Organization):
SONIA BURGESS (R3)
GLENN MEYER (R1)
MARK LESSER (R2)
LINDA SMITH (R4)
VERN HODGE (NRR)
SONIA BURGESS (R3)
GLENN MEYER (R1)
MARK LESSER (R2)
LINDA SMITH (R4)
VERN HODGE (NRR)
OVERSTRESS CONDITION ON "SINGLE FAILURE PROOF" CRANE TROLLEYS
"On January 5, 2005 as a part of a crane re-rate analyses and study Whiting Corporation identified an overstress condition on some hoist equalizer plates and welds. This condition is limited to the hoists of some redundant (single failure proof) cranes.
"Whiting Corporation has performed a preliminary review and have isolated the problem to the family of redundant trolleys also known as single failure proof trolleys. No other types of cranes are affected. It has not been established at this time which specific redundant trolleys are impacted. This assessment will require a cases by case review.
"Whiting Corporation have or are attempting to contact these customers directly to notify them of this circumstance. These are the only potentially impacted customers.
"The hoist units identified above, are to be inspected as follows and then limited to 50% of rated capacity until such time as the units can be evaluated and/or upgraded. The following specific serial numbers can be operated at 100 Tons (SN 10403, 10388, 10389, 10510). SN 10698 is currently being evaluated and is limited in capacity by other factors being addressed with the customer. The area to visually inspect, for cracks in the plates or welds, is the assembly, adjacent to the rope termination, at each end of the equalizer arm, that the nut on the rope fitting bears against. Suspicious visual indications of potential cracks can be further examined by Magnetic Particle testing if warranted. A lack of any visible cracks during visual examination will allow the unit to be placed in operation at the 50% reduced capacity. Please note no reports of field failures or cracks have been reported as of the issuance of this notice.
"The following is a list of the family of redundant (single failure proof) cranes that will require a detailed evaluation.
Niagara Mohawk Power - Nine Mile Point -125 Ton
Exelon Corporation (Commonwealth Edison) - Dresden Station -125 Ton
Exelon Corporation (Commonwealth Edison) - Quad Cities Station -125 Ton
Dominion Nuclear Connecticut-North East Utilities-Millstone (Believed to be Unit 1 in Waterford)-Reactor Room
Entergy Nuclear (Vermont Yankee) - Vernon Station - Reactor Room-110 Ton
Neb. Public Power - Cooper Nuclear Station - Reactor Room -100 Ton
Exelon Corporation (Philadelphia Electric) - Peach Bottom -125 Ton (2)
(AEP) (Indiana Michigan power) - D. C. Cook Station -150 Ton
Carolina Power & Light - Brunswick Station -125 Ton
Southern Nuclear (Alabama Power) - Farley Plant - 125 Ton
Energy Northwest (WPPSS) -Hanford Unit # 2 - Reactor Room -125 Ton
Progress Energy (PGN) (Carolina Power & Light) - Robinson Station -125 Ton
Mississippi Power & Light - Grand Gulf Station -150 Ton (2)
Long Island Lighting - Shoreham Station -125 Ton
Constellation Nuclear (Niagara Mohawk Power) - Nine Mile Point Station -125 Ton
AEP (Indiana Michigan power) - D. C. Cook Station -150 Ton
Indiana Michigan power - D. C. Cook Station - 20 Ton"
"On January 5, 2005 as a part of a crane re-rate analyses and study Whiting Corporation identified an overstress condition on some hoist equalizer plates and welds. This condition is limited to the hoists of some redundant (single failure proof) cranes.
"Whiting Corporation has performed a preliminary review and have isolated the problem to the family of redundant trolleys also known as single failure proof trolleys. No other types of cranes are affected. It has not been established at this time which specific redundant trolleys are impacted. This assessment will require a cases by case review.
"Whiting Corporation have or are attempting to contact these customers directly to notify them of this circumstance. These are the only potentially impacted customers.
"The hoist units identified above, are to be inspected as follows and then limited to 50% of rated capacity until such time as the units can be evaluated and/or upgraded. The following specific serial numbers can be operated at 100 Tons (SN 10403, 10388, 10389, 10510). SN 10698 is currently being evaluated and is limited in capacity by other factors being addressed with the customer. The area to visually inspect, for cracks in the plates or welds, is the assembly, adjacent to the rope termination, at each end of the equalizer arm, that the nut on the rope fitting bears against. Suspicious visual indications of potential cracks can be further examined by Magnetic Particle testing if warranted. A lack of any visible cracks during visual examination will allow the unit to be placed in operation at the 50% reduced capacity. Please note no reports of field failures or cracks have been reported as of the issuance of this notice.
"The following is a list of the family of redundant (single failure proof) cranes that will require a detailed evaluation.
Niagara Mohawk Power - Nine Mile Point -125 Ton
Exelon Corporation (Commonwealth Edison) - Dresden Station -125 Ton
Exelon Corporation (Commonwealth Edison) - Quad Cities Station -125 Ton
Dominion Nuclear Connecticut-North East Utilities-Millstone (Believed to be Unit 1 in Waterford)-Reactor Room
Entergy Nuclear (Vermont Yankee) - Vernon Station - Reactor Room-110 Ton
Neb. Public Power - Cooper Nuclear Station - Reactor Room -100 Ton
Exelon Corporation (Philadelphia Electric) - Peach Bottom -125 Ton (2)
(AEP) (Indiana Michigan power) - D. C. Cook Station -150 Ton
Carolina Power & Light - Brunswick Station -125 Ton
Southern Nuclear (Alabama Power) - Farley Plant - 125 Ton
Energy Northwest (WPPSS) -Hanford Unit # 2 - Reactor Room -125 Ton
Progress Energy (PGN) (Carolina Power & Light) - Robinson Station -125 Ton
Mississippi Power & Light - Grand Gulf Station -150 Ton (2)
Long Island Lighting - Shoreham Station -125 Ton
Constellation Nuclear (Niagara Mohawk Power) - Nine Mile Point Station -125 Ton
AEP (Indiana Michigan power) - D. C. Cook Station -150 Ton
Indiana Michigan power - D. C. Cook Station - 20 Ton"
Other Nuclear Material
Event Number: 41325
Rep Org: US ARMY
Licensee: US ARMY
Region: 3
City: ROCK ISLAND State: IL
County:
License #: 12-00722-16
Agreement: Y
Docket:
NRC Notified By: THOMAS GIZICKI
HQ OPS Officer: STEVE SANDIN
Licensee: US ARMY
Region: 3
City: ROCK ISLAND State: IL
County:
License #: 12-00722-16
Agreement: Y
Docket:
NRC Notified By: THOMAS GIZICKI
HQ OPS Officer: STEVE SANDIN
Notification Date: 01/12/2005
Notification Time: 16:36 [ET]
Event Date: 01/05/2005
Event Time: 00:00 [CST]
Last Update Date: 01/12/2005
Notification Time: 16:36 [ET]
Event Date: 01/05/2005
Event Time: 00:00 [CST]
Last Update Date: 01/12/2005
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
MONTE PHILLIPS (R3)
RUSSELL BYWATER (R4)
THOMAS ESSIG (NMSS)
MONTE PHILLIPS (R3)
RUSSELL BYWATER (R4)
THOMAS ESSIG (NMSS)
TWO LOST M43A1 CHEMICAL AGENT DETECTORS CONTAINING AM-241 SEALED SOURCES
On 1/5/05 during maintenance activities at the Oregon National Guard Camp Withycombe located in Clackamas, OR, two (2) M43A1 Chemical Agent Cells [reg. device #1129-D-102S] were discovered missing. Each missing Chemical Agent Cell contained an Am-241sealed source of 250 microCuries. The serial numbers for the two (2) missing sources are Z03-C-12123 and Z03-C-05051. An exhaustive search of the maintenance area including the low-level waste disposal facility was conducted with negative results.
On 1/5/05 during maintenance activities at the Oregon National Guard Camp Withycombe located in Clackamas, OR, two (2) M43A1 Chemical Agent Cells [reg. device #1129-D-102S] were discovered missing. Each missing Chemical Agent Cell contained an Am-241sealed source of 250 microCuries. The serial numbers for the two (2) missing sources are Z03-C-12123 and Z03-C-05051. An exhaustive search of the maintenance area including the low-level waste disposal facility was conducted with negative results.