Event Notification Report for December 23, 2004

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
12/22/2004 - 12/23/2004

EVENT NUMBERS
4128841289412904128641300

Power Reactor
Event Number: 41288
Facility: MCGUIRE
Region: 2     State: NC
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: FRED KIRK
HQ OPS Officer: BILL GOTT
Notification Date: 12/23/2004
Notification Time: 17:46 [ET]
Event Date: 12/23/2004
Event Time: 14:10 [EST]
Last Update Date: 12/23/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
CAUDLE JULIAN (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
LOSS OF COMMUNICATIONS

"Test results for the 12/23/04 weekly McGuire Nuclear Station silent siren test performed by the counties located in the McGuire EPZ indicated a failure of 50 out of the 67 sirens. This failure involved all of the sirens located in 2 of the 4 counties located in the EPZ who have the capability to activate these sirens. This failure occurred at 1410 on 12/23/04 and is believed to be due to 'Tropospheric Ducting (TD) radio frequency interference (RFI). A strong weather front was moving through the area at the time of the testing and is believed to be the cause of the TD RFI. Interference cleared at 1425 and subsequent retest by all four affected counties were completed with a 100% success rate with all siren test indications normal. Due to the short period of time of the unavailability and the prompt restoration of function, backup route alerting was not established. Long-term resolution of this RFI problem is being developed."

The licensee notified the NRC Resident Inspector.


Fuel Cycle Facility
Event Number: 41289
Facility: FRAMATOME ANP
Region: 2     State: VA
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
NRC Notified By: CHARLES HOLMAN
HQ OPS Officer: JANELLE BATTISTE
Notification Date: 12/23/2004
Notification Time: 20:03 [ET]
Event Date: 12/23/2004
Event Time: 00:00 [EST]
Last Update Date: 12/23/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
20.1906(d)(2) - EXTERNAL RAD LEVELS > LIMITS
Person (Organization):
CAUDLE JULIAN (R2)
RICHARD CONTE (R1)
SCOTT FLANDERS (NMSS)
Event Text
EXTERNAL RADIATION LEVELS GREATER THAN LIMITS

On a shipment received from Hope Creek, one of eight packages had a high radiation level on the bottom of the package. The radiation level was 236 millirem/hour. The packages contained nuclear service equipment. Packages were offloaded and placed in a secure area of the plant. The package has not been opened. Framatome has notified Hope Creek and will notify the shipper.


Power Reactor
Event Number: 41290
Facility: PERRY
Region: 3     State: OH
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: JIM CASE
HQ OPS Officer: BILL HUFFMAN
Notification Date: 12/24/2004
Notification Time: 03:07 [ET]
Event Date: 12/23/2004
Event Time: 23:54 [EST]
Last Update Date: 12/24/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL
Person (Organization):
LAURA KOZAK (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 A/R Y 44 Power Operation 0 Hot Shutdown
Event Text
REACTOR SCRAM FOLLOWING DOWN SHIFT OF BOTH RECIRC PUMPS FROM FAST TO SLOW SPEED

"At 2345 on 12/23/04 both reactor recirc pumps down shifted from fast to slow speed which resulted in reactor power reducing from 100% to 44%. At 2354 an automatic scram occurred from the activation of the Oscillation Power Range Monitor (OPRM) instrumentation. After the scram all safety systems responded as designed. Cause of the reactor recirc pump downshift is still under discovery."

All rods fully inserted. No safety relief valves lifted during the transient. The licensee was in no major LCO at the time. Pressure control is via the steam bypass valves.

The licensee has notified the NRC Resident Inspector.


Power Reactor
Event Number: 41286
Facility: DAVIS BESSE
Region: 3     State: OH
Unit: [1] [] []
RX Type: [1] B&W-R-LP
NRC Notified By: DAN HARTNETT
HQ OPS Officer: BILL GOTT
Notification Date: 12/23/2004
Notification Time: 13:45 [ET]
Event Date: 12/23/2004
Event Time: 06:14 [EST]
Last Update Date: 12/23/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
LAURA KOZAK (R3)
ERIC LEEDS (NSIR)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
LOSS OF RESPONSE CAPABILITY

"At 0614 hours on December 23, 2004, Davis-Besse activated station isolation procedures due to heavy snow and blowing snow. This is being reported as a loss of response capability under 10CFR 50.72 (b)(3)(xiii) due to the potential inability of local authorities to perform an evacuation. Minimum Emergency Response staffing is being maintained at the site. The state of Ohio and Ottawa and Lucas Counties have confirmed that they are currently capable of performing their emergency plan responsibilities."

The licensee notified the NRC Resident Inspector.


General Information or Other
Event Number: 41300
Rep Org: MA RADIATION CONTROL PROGRAM
Licensee: UNIVERSITY OF MASS - AMHERST
Region: 1
City: AMHERST   State: MA
County:
License #: 60-0107
Agreement: Y
Docket:
NRC Notified By: JOHN SUMARES
HQ OPS Officer: JEFF ROTTON
Notification Date: 12/30/2004
Notification Time: 11:25 [ET]
Event Date: 12/23/2004
Event Time: 15:30 [EST]
Last Update Date: 12/30/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JAMES TRAPP (R1)
ELMO COLLINS (NMSS)
AARON DANIS (TAS)
Event Text
AGREEMENT STATE LOST RADIOACTIVE SOURCE

"University of Mass - Amherst called [Massachusetts Radiation Control Program] to report a missing Ni-63 source in an ECD detector. A Varian Model 3700 gas chromatograph [GC] machine was due for leak testing on 11/15/04. The unit could not be found and was presumed missing. The unit's ECD contained a Ni-63 source (8 milliCurie) and had serial number A3240. In Sept / Oct of 2004, laboratory equipment was moved and / or sent to the trash. It is suspected that the missing GC was mistakenly sent out for disposal at that time, and in Nov. 2004, the licensee determined the unit was missing."

The calibration date of the source activity was not known at the time of the report. The last known confirmed inventory of the device was when the last leak test was performed in May 2004