Event Notification Report for December 21, 2004
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
12/20/2004 - 12/21/2004
Research Reactor
Event Number: 41275
Rep Org: TEXAS A&M UNIVERSITY
Licensee: TEXAS A&M UNIVERSITY
Region: 4
City: COLLEGE STATION State: TX
County: BRAZOS
License #: R-83
Agreement: Y
Docket: 05000128
NRC Notified By: WARREN REECE
HQ OPS Officer: JOHN MacKINNON
Licensee: TEXAS A&M UNIVERSITY
Region: 4
City: COLLEGE STATION State: TX
County: BRAZOS
License #: R-83
Agreement: Y
Docket: 05000128
NRC Notified By: WARREN REECE
HQ OPS Officer: JOHN MacKINNON
Notification Date: 12/21/2004
Notification Time: 14:47 [ET]
Event Date: 12/21/2004
Event Time: 12:45 [CST]
Last Update Date: 12/21/2004
Notification Time: 14:47 [ET]
Event Date: 12/21/2004
Event Time: 12:45 [CST]
Last Update Date: 12/21/2004
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
Person (Organization):
BLAIR SPITZBERG (R4)
PAT MADDEN (NRR)
PETER WILSON (IRD)
SANDRA WASLTER (NMSS)
KAREN (DHS)
BLAIR SPITZBERG (R4)
PAT MADDEN (NRR)
PETER WILSON (IRD)
SANDRA WASLTER (NMSS)
KAREN (DHS)
UNUSUAL EVENT DECLARED DUE TO A GRASS FIRE.
A small grass fire started near Texas A&M Gamma Shack and headed away from the Gamma Shack and away from Texas A&M TRIGA Reactor Confinement building (located 100 yards away from the fire). The grass fire did not threaten the Gamma Shack or the Reactor Confinement building. Licensee entered an unusual event per Standard Operating Procedure Section 9, Procedure D.1 (major fire - major fire is a fire that cannot not be extinguished with one fire extinguisher). The reactor was scrammed at 1249 CST and all 5 rods fully inserted into the core (reactor was at 1000 KW when it was scrammed). Local Fire Department and local police responded. Fire Department extinguished the fire. No damage to the Gamma Shack. Gamma Shack is used to store cesium-137 and cobalt-60 calibration sources (sources were stored down in their respective wells). Licensee exited the Unusual Event at 1347 CST after the fire was extinguished by the local fire department. The TRIGA reactor will be restarted later this afternoon. No releases or injuries due to the fire.
A small grass fire started near Texas A&M Gamma Shack and headed away from the Gamma Shack and away from Texas A&M TRIGA Reactor Confinement building (located 100 yards away from the fire). The grass fire did not threaten the Gamma Shack or the Reactor Confinement building. Licensee entered an unusual event per Standard Operating Procedure Section 9, Procedure D.1 (major fire - major fire is a fire that cannot not be extinguished with one fire extinguisher). The reactor was scrammed at 1249 CST and all 5 rods fully inserted into the core (reactor was at 1000 KW when it was scrammed). Local Fire Department and local police responded. Fire Department extinguished the fire. No damage to the Gamma Shack. Gamma Shack is used to store cesium-137 and cobalt-60 calibration sources (sources were stored down in their respective wells). Licensee exited the Unusual Event at 1347 CST after the fire was extinguished by the local fire department. The TRIGA reactor will be restarted later this afternoon. No releases or injuries due to the fire.
General Information or Other
Event Number: 41287
Rep Org: CALIFORNIA RADIATION CONTROL PRGM
Licensee: GLOBAL PROCESS DIAGNOSTICS INC
Region: 4
City: CARSON State: CA
County:
License #: L05155
Agreement: Y
Docket:
NRC Notified By: ROBERT GREGER
HQ OPS Officer: CHAUNCEY GOULD
Licensee: GLOBAL PROCESS DIAGNOSTICS INC
Region: 4
City: CARSON State: CA
County:
License #: L05155
Agreement: Y
Docket:
NRC Notified By: ROBERT GREGER
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 12/23/2004
Notification Time: 17:05 [ET]
Event Date: 12/21/2004
Event Time: 00:00 [PST]
Last Update Date: 12/23/2004
Notification Time: 17:05 [ET]
Event Date: 12/21/2004
Event Time: 00:00 [PST]
Last Update Date: 12/23/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
BLAIR SPITZBERG (R4)
SCOTT FLANDERS (NMSS)
BLAIR SPITZBERG (R4)
SCOTT FLANDERS (NMSS)
AGREEMENT STATE REPORT
"It was reported to Radiological Health Branch (RHB), Granada Hills that a Texas licensee, Gamma Surveys, a Division of Global Process Diagnostics, Inc. ( Gamma Surveys) , was conducting density level measurements using sealed sources under reciprocity at the Conoco Phillips Corporation refinery in Carson, CA, the evening of 12/21/04. Special form sealed sources containing radioactive material are employed for "gamma scanning," diagnostic evaluation, typically density or level measurements, of industrial processes or equipment. At about 1900 one such source, 287 mCi, Co-60, contained in a collimating device at the end of a stainless-steel, stranded cable, was being lowered down the outside of a large, cylindrical "distillation vessel, " designated FR-1 Flasher Column, 200 ft. high and 28 ft. in diameter. Stiffening rings which protrude about 18 inches externally encircle the vessel at various heights. As the source is being lowered down the side of the vessel, the operator located at the top of the vessel must manually "shake" the cable to get the source over the protruding stiffening rings. On this occasion, the collimating device with the Co-60 source broke at the cable during this shaking to get it over a stiffening ring 20 feet from the top. The source came to rest on the stiffening ring, in the " unshielded" condition, where it remained overnight. However, Gamma Surveys indicated that the area was cleared of personnel and cordoned off. Radiation surveys were taken at the ground level showing no appreciable dose rates, approximately 0.04 mR/hr.
"The next day, 12/22/04, Gamma Surveys proposed a recovery plan to lower an operator in a man-basket down to the source to manually put the source back in its shielded condition ( normal practice) and then attach a replacement cable to the collimating device so that it may be reeled back into its shielded container at the top of the vessel for subsequent evaluation and repair of the damaged system. After consultation with RHB staff and the RSO for Gamma Surveys, this plan was effected. By about 5 PM, 12/22/04, the source recovery was completed without problems.
An investigation has been initiated to follow-up."
"It was reported to Radiological Health Branch (RHB), Granada Hills that a Texas licensee, Gamma Surveys, a Division of Global Process Diagnostics, Inc. ( Gamma Surveys) , was conducting density level measurements using sealed sources under reciprocity at the Conoco Phillips Corporation refinery in Carson, CA, the evening of 12/21/04. Special form sealed sources containing radioactive material are employed for "gamma scanning," diagnostic evaluation, typically density or level measurements, of industrial processes or equipment. At about 1900 one such source, 287 mCi, Co-60, contained in a collimating device at the end of a stainless-steel, stranded cable, was being lowered down the outside of a large, cylindrical "distillation vessel, " designated FR-1 Flasher Column, 200 ft. high and 28 ft. in diameter. Stiffening rings which protrude about 18 inches externally encircle the vessel at various heights. As the source is being lowered down the side of the vessel, the operator located at the top of the vessel must manually "shake" the cable to get the source over the protruding stiffening rings. On this occasion, the collimating device with the Co-60 source broke at the cable during this shaking to get it over a stiffening ring 20 feet from the top. The source came to rest on the stiffening ring, in the " unshielded" condition, where it remained overnight. However, Gamma Surveys indicated that the area was cleared of personnel and cordoned off. Radiation surveys were taken at the ground level showing no appreciable dose rates, approximately 0.04 mR/hr.
"The next day, 12/22/04, Gamma Surveys proposed a recovery plan to lower an operator in a man-basket down to the source to manually put the source back in its shielded condition ( normal practice) and then attach a replacement cable to the collimating device so that it may be reeled back into its shielded container at the top of the vessel for subsequent evaluation and repair of the damaged system. After consultation with RHB staff and the RSO for Gamma Surveys, this plan was effected. By about 5 PM, 12/22/04, the source recovery was completed without problems.
An investigation has been initiated to follow-up."
General Information or Other
Event Number: 41305
Rep Org: MARYLAND DEPT OF THE ENVIRONMENT
Licensee: ADVANCED RADIOLOGY
Region: 1
City: GLEN BURNIE State: MD
County:
License #: MD-03-040-01
Agreement: Y
Docket:
NRC Notified By: RAY MANLEY
HQ OPS Officer: CHAUNCEY GOULD
Licensee: ADVANCED RADIOLOGY
Region: 1
City: GLEN BURNIE State: MD
County:
License #: MD-03-040-01
Agreement: Y
Docket:
NRC Notified By: RAY MANLEY
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 01/03/2005
Notification Time: 13:07 [ET]
Event Date: 12/21/2004
Event Time: 00:00 [EST]
Last Update Date: 01/03/2005
Notification Time: 13:07 [ET]
Event Date: 12/21/2004
Event Time: 00:00 [EST]
Last Update Date: 01/03/2005
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
JAMES TRAPP (R1)
SCOTT MOORE (NMSS)
JAMES TRAPP (R1)
SCOTT MOORE (NMSS)
AGREEMENT STATE REPORT OF A LOST COBALT- 57 SOURCE
The State Licensee, Advanced Radiology, located at the PET Center at North Arundel Tate Center in Glen Burnie, MD reported that a Model BM06 Gamma Reference Standard calibration device containing 5.66 milliCuries of Co-57 source is missing. The source has not been located and is believed to have been inadvertently disposed of in the trash by housekeeping when they made unauthorized entry to the hot lab. As a corrective action the hot lab door lock was changed. The State of Maryland responded on 12/30/04.
The State Licensee, Advanced Radiology, located at the PET Center at North Arundel Tate Center in Glen Burnie, MD reported that a Model BM06 Gamma Reference Standard calibration device containing 5.66 milliCuries of Co-57 source is missing. The source has not been located and is believed to have been inadvertently disposed of in the trash by housekeeping when they made unauthorized entry to the hot lab. As a corrective action the hot lab door lock was changed. The State of Maryland responded on 12/30/04.