Power Reactor
Event Number: 41257
Facility: TURKEY POINT
Region: 2     State: FL
Unit: [3] [] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: SCOTT MEIER
HQ OPS Officer: JOHN KNOKE
Notification Date: 12/14/2004
Notification Time: 12:45 [ET]
Event Date: 12/14/2004
Event Time: 11:45 [EST]
Last Update Date: 12/14/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL
Person (Organization):
ROBERT HAAG (R2)
TERRY REIS (NRR)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 M/R Y 100 Power Operation 0 Hot Standby
Event Text
REACTOR MANUALLY TRIPPED DUE TO FIRE ON UNIT 3 HP TURBINE

" U3 manually tripped (Shift Manager decision). Fire in U3 HP turbine near bearing housing (offsite assistance not required). All plant equipment functioned as designed."

A fire broke out near the #2 bearing housing on Unit 3 HP turbine and lasted about 9 minutes in length. Exact character of fire was not available at time of reporting. No unusual vibration readings or visual indications were observed prior to fire. Onsite fire brigade personnel responded to the turbine area without assistance of offsite emergency personnel. Five minutes into the event Unit 3 reactor was manually tripped. Nine minutes into the event, shift supervisor declared the fire was out. Fire personnel indicated the fire was "easily" put out. Licensee is evaluating action to be taken.

When Unit 3 reactor was manually tripped, all rods inserted fully. No primary or secondary power relief valves actuated. AFW activated as expected. Licensee chose to close the MSIV to slow down the cooldown rate. Presently, decay heat is being removed via the steam dump into the atmosphere.

Fire did not affect operational ability of Unit 4 or cause instability on the electrical grid.

The licensee has notified the NRC Resident Inspector.


Other Nuclear Material
Event Number: 41259
Rep Org: NATIONAL RESPONSE CENTER
Licensee: ROZELL TESTING LABORATORIES
Region: 3
City: SPRINGFIELD   State: MO
County:
License #: 24-32438-01
Agreement: N
Docket:
NRC Notified By: MS. CRUZ
HQ OPS Officer: MIKE RIPLEY
Notification Date: 12/14/2004
Notification Time: 17:10 [ET]
Event Date: 12/14/2004
Event Time: 15:45 [CST]
Last Update Date: 12/14/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
ROGER LANKSBURY (R3)
MELVYN LEACH (NMSS)
Event Text
DAMAGED TROXLER MOISTURE DENSITY GAUGE

The National Response Center reported that the licensee reported to them that a moisture density gauge was run over by a bulldozer at a construction site in Springfield, MO and that the area had been isolated.

In contacting the licensee, the RSO stated that the extent of damage to the gauge (Model 3440 Troxler 8 mCi Cs-137 and 40 mCi Am-241:Be) was as of yet unknown. The licensee plans on requesting local fire department Haz Mat Team assistance in performing surveys and will contact Troxler for information on recovering and returning the gauge. The licensee will be providing an update with additional details and status.

* * * UPDATE FROM E. HODGE (RSO) TO M. RIPLEY 2013 EST, 12/14/04 * * *

The licensee reported that the Springfield, MO Fire Department responded to the construction site, assisted in returning the damaged gauge to its transportation case, and performed a radiation survey of the gauge and the area where it was damaged. No area contamination or apparent source leakage was noted. The area has been cleared for access, and the gauge is being returned to the licensee's laboratory in Branson, MO where source leak testing will be performed prior to shipment to the manufacturer.

Notified R3 DO (Lanksbury) and NMSS EO (Leach).


Power Reactor
Event Number: 41260
Facility: NINE MILE POINT
Region: 1     State: NY
Unit: [1] [2] []
RX Type: [1] GE-2,[2] GE-5
NRC Notified By: MATTHEW MINNICK
HQ OPS Officer: BILL HUFFMAN
Notification Date: 12/14/2004
Notification Time: 20:03 [ET]
Event Date: 12/14/2004
Event Time: 18:43 [EST]
Last Update Date: 12/14/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
KENNETH JENISON (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
OSWEGO COUNTY PROMPT NOTIFICATION SYSTEM OUT OF SERVICE FOR GREATER THAN ONE HOUR

"Notified by [deleted] of the Oswego County Warning Point that the tone alert system (prompt notification system) was out of service for more than one hour as of 18:43 on 12/14/04. This requires a notification to the NRC for a major loss of notification capability in accordance with 10CFR50.72. The notification [from the County Warning Point] occurred on 12/14/04 at 19:07 via the RECS line (Radiological Emergency Communications System). Route Alert has been verified available [as backup to the tone alert system] and actions to restore [the tone alert system] are in progress."

The licensee states that the malfunction on the prompt notification system only rendered the tone alert radio system inoperable. The emergency sirens are not affected.

The licensee has notified the NRC Resident Inspector and Oswego County authorities. The licensee has also notified the Fitzpatrick nuclear power plant.

* * * UPDATE FROM NINE MILE POINT (D. MOORE) TO NRC (HUFFMAN) AT 23:06 EST ON 12/14/04 * * *

The prompt notification tone alert system was restored to operable at 21:45 EST on 12/14/04. Fitzpatrick and Oswego county are informed.


Power Reactor
Event Number: 41261
Facility: FITZPATRICK
Region: 1     State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: DAVID SPINDLER
HQ OPS Officer: MIKE RIPLEY
Notification Date: 12/14/2004
Notification Time: 23:22 [ET]
Event Date: 12/14/2004
Event Time: 18:43 [EST]
Last Update Date: 12/14/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
KENNETH JENISON (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
OSWEGO COUNTY PROMPT NOTIFICATION SYSTEM OUT OF SERVICE FOR GREATER THAN ONE HOUR

"Oswego County Prompt Notification System was out of service greater than 1 hour. Time out of service 12/14/03 at 1843 [EST]. Time returned to service 12/14/04 at 2305 [EST]."

The licensee notified the NRC Resident Inspector.


General Information or Other
Event Number: 41262
Rep Org: NC DIV OF RADIATION PROTECTION
Licensee: ENGINEERING TECHTONICS
Region: 1
City: WINSTON-SALEM   State: NC
County:
License #:
Agreement: Y
Docket:
NRC Notified By: LEE COX
HQ OPS Officer: BILL HUFFMAN
Notification Date: 12/14/2004
Notification Time: 23:09 [ET]
Event Date: 12/14/2004
Event Time: 15:00 [EST]
Last Update Date: 12/15/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
KENNETH JENISON (R1)
MELVYN LEACH (NMSS)
Event Text
AGREEMENT STATE REPORT OF PORTABLE NUCLEAR GAUGE LOST DURING TRUCK CRASH

A representative from the North Carolina Radiation Materials Branch called to report the loss of a Humboldt Portable Nuclear Gauge (Serial #254; Model 5001) due a severe truck crash on or near highway 52 close to Winston-Salem NC. The accident occurred around 15:00 on 12/14/04. The gauge is believe to have a 10 milliCurie Cs-137; 40 milliCurie Am-241,Be source.

A truck carrying the gauge had an accident and rolled multiple times. It is believed that the gauge was ejected and probably in brush or woods in the vicinity of the crash site. A search was conducted until dark and will resume tomorrow (12/15/04) at around 0600.

The licensee for the gauge is a company named Engineering Techtonics licensed by NC. The State of NC has contacted the RSO for the company.

* * * UPDATE FROM L COX TO W GOTT AT 0814 ON 12/15/04 * * *

The gauge was recovered at 0742 EST 12/15/04 and is in the possession of the licensee. The gauge was still in its transport case. The case was still locked, the gauge was still locked, and there was no visible damage to the gauge. Radiation surveys of the area are normal. The licensee plans to ship the gauge to the manufacturer for further inspection.

Notified NMSS (J Hickey) and R1DO (K Jenison).