Event Notification Report for November 18, 2004
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
11/17/2004 - 11/18/2004
General Information or Other
Event Number: 41210
Rep Org: MISSISSIPPI DIV OF RAD HEALTH
Licensee: BAPTIST MEMORIAL HOSPITAL - NORTH MISSISSIPPI
Region: 1
City: State: MS
County:
License #: MS-232-02
Agreement: Y
Docket:
NRC Notified By: BOBBY SMITH
HQ OPS Officer: STEVE SANDIN
Licensee: BAPTIST MEMORIAL HOSPITAL - NORTH MISSISSIPPI
Region: 1
City: State: MS
County:
License #: MS-232-02
Agreement: Y
Docket:
NRC Notified By: BOBBY SMITH
HQ OPS Officer: STEVE SANDIN
Notification Date: 11/19/2004
Notification Time: 12:36 [ET]
Event Date: 11/18/2004
Event Time: 00:00 [CST]
Last Update Date: 12/08/2004
Notification Time: 12:36 [ET]
Event Date: 11/18/2004
Event Time: 00:00 [CST]
Last Update Date: 12/08/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
KENNETH JENISON (R1)
SCOTT MOORE (NMSS)
KENNETH JENISON (R1)
SCOTT MOORE (NMSS)
AGREEMENT STATE REPORT INVOLVING A THERAPY MISADMINISTRATION
The following information was provided via email from the Radioactive Materials Branch Director, Division of Radiological Health, MS State Dept. of Health:
"On November 18, 2004, licensee's RSO notified Division of Radiological Health/MS State Dept. of Health, of a Iodine-125 therapy misadministration. The prescribed treatment was for 145 gray to the prostate gland; however, due to an error concerning the coordinates, the treatment area was partially missed and resulted in a greater than 10 gray treatment to the rectum. The isotope was Iodine -125, 88 seeds with average activity of .300 millicuries, total activity of 26.8 millicuries. The patient was notified of the error and agreed to have the treatment performed again with no problems occurring. The RSO notified DRH after discussing the error with the authorized user and agreeing on corrective actions to prevent reoccurrence. At the present time, this is all the information we have received. I will update as soon as possible."
* * * UPDATE PROVIDED BY SMITH TO JEFF ROTTON AT 1738 EST ON 12/08/04 * * *
The following update information was provided via email from MS State Department of Health:
"The cause of the misadministration appears to be a misinterpretation to an ultrasound image which resulted in the needle being inserted in the wrong area. This caused a lower dose to be administered to the prostate gland greater than 20 % dose of the prescribed dose. Corrective actions will require a fIuoroscopticimage to verify the coordinates and confirm needle placement."
Notified R1DO (Anderson) and NMSS EO (Giitter)
The following information was provided via email from the Radioactive Materials Branch Director, Division of Radiological Health, MS State Dept. of Health:
"On November 18, 2004, licensee's RSO notified Division of Radiological Health/MS State Dept. of Health, of a Iodine-125 therapy misadministration. The prescribed treatment was for 145 gray to the prostate gland; however, due to an error concerning the coordinates, the treatment area was partially missed and resulted in a greater than 10 gray treatment to the rectum. The isotope was Iodine -125, 88 seeds with average activity of .300 millicuries, total activity of 26.8 millicuries. The patient was notified of the error and agreed to have the treatment performed again with no problems occurring. The RSO notified DRH after discussing the error with the authorized user and agreeing on corrective actions to prevent reoccurrence. At the present time, this is all the information we have received. I will update as soon as possible."
* * * UPDATE PROVIDED BY SMITH TO JEFF ROTTON AT 1738 EST ON 12/08/04 * * *
The following update information was provided via email from MS State Department of Health:
"The cause of the misadministration appears to be a misinterpretation to an ultrasound image which resulted in the needle being inserted in the wrong area. This caused a lower dose to be administered to the prostate gland greater than 20 % dose of the prescribed dose. Corrective actions will require a fIuoroscopticimage to verify the coordinates and confirm needle placement."
Notified R1DO (Anderson) and NMSS EO (Giitter)
General Information or Other
Event Number: 41206
Rep Org: NC DIV OF RADIATION PROTECTION
Licensee: NC ENVIRONMENTAL HEALTH SERVICES
Region: 1
City: RALEIGH State: NC
County:
License #: 092-0456-17
Agreement: Y
Docket:
NRC Notified By: LARRY MICHAELS
HQ OPS Officer: HOWIE CROUCH
Licensee: NC ENVIRONMENTAL HEALTH SERVICES
Region: 1
City: RALEIGH State: NC
County:
License #: 092-0456-17
Agreement: Y
Docket:
NRC Notified By: LARRY MICHAELS
HQ OPS Officer: HOWIE CROUCH
Notification Date: 11/18/2004
Notification Time: 18:15 [ET]
Event Date: 11/18/2004
Event Time: 15:52 [EST]
Last Update Date: 11/18/2004
Notification Time: 18:15 [ET]
Event Date: 11/18/2004
Event Time: 15:52 [EST]
Last Update Date: 11/18/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
KENNETH JENISON (R1)
DANIEL GILLEN (NMSS)
KENNETH JENISON (R1)
DANIEL GILLEN (NMSS)
AGREEMENT STATE REPORT - LEAD PAINT ANALYZER MISSING AND THEN RECOVERED
An employee of the North Carolina Department of Environmental Health [NCDEH], Environmental Health Services reported to his supervisor on 11/18/04 that his Niton XRF lead paint analyzer device was missing or stolen from the trunk of his car. After retracing his travels going back to the last time he used the device on 11/09/04, it was discovered that he had inadvertently left the device in the parking lot of the Union County Health Department where he had earlier performed a lead investigation. An Union County Health Department employee had found the locked device on 11/09/04 in the parking lot and secured it in their building.
The device will be retrieved by a NCDEH employee on 11/19/04. The device contains 14 milliCuries of Cadmium-109. The device serial number is U1399. The sealed source serial number is NR4649.
An employee of the North Carolina Department of Environmental Health [NCDEH], Environmental Health Services reported to his supervisor on 11/18/04 that his Niton XRF lead paint analyzer device was missing or stolen from the trunk of his car. After retracing his travels going back to the last time he used the device on 11/09/04, it was discovered that he had inadvertently left the device in the parking lot of the Union County Health Department where he had earlier performed a lead investigation. An Union County Health Department employee had found the locked device on 11/09/04 in the parking lot and secured it in their building.
The device will be retrieved by a NCDEH employee on 11/19/04. The device contains 14 milliCuries of Cadmium-109. The device serial number is U1399. The sealed source serial number is NR4649.
Power Reactor
Event Number: 41207
Facility: KEWAUNEE
Region: 3 State: WI
Unit: [1] [] []
RX Type: [1] W-2-LP
NRC Notified By: DAVE KARST
HQ OPS Officer: HOWIE CROUCH
Region: 3 State: WI
Unit: [1] [] []
RX Type: [1] W-2-LP
NRC Notified By: DAVE KARST
HQ OPS Officer: HOWIE CROUCH
Notification Date: 11/18/2004
Notification Time: 18:59 [ET]
Event Date: 11/18/2004
Event Time: 16:30 [CST]
Last Update Date: 11/18/2004
Notification Time: 18:59 [ET]
Event Date: 11/18/2004
Event Time: 16:30 [CST]
Last Update Date: 11/18/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(C) - POT UNCNTRL RAD REL
10 CFR Section:
50.72(b)(3)(v)(C) - POT UNCNTRL RAD REL
Person (Organization):
JAMES CREED (R3)
JAMES CREED (R3)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Refueling | 0 | Refueling |
BOTH TRAINS OF RADIATION MONITORING AUTOMATIC ISOLATION FEATURES DISABLED DURING REFUELING OPERATIONS
The following information was obtained from the licensee via facsimile:
"At 1630 [hrs CST] the control room was performing head lift and pre-rod drive unlatching checkout and discovered R-12 (Containment Radiation Monitor) would not isolate reactor ventilation isolation. Investigation found that work on Engineered Safeguards Features pre-startup logic test had defeated both Train A and B automatic isolation signals to [Reactor Building Ventilation]. This test was started and signals defeated at 0803 [hrs.] and 0804 [hrs.]. Refueling evolutions, upper internals lift and rod latching were performed. Technical Specifications require auto-isolation capability for [Reactor Building Ventilation] during refueling ops.
"Both R-12 and R-21 would respond to high radiation and manual isolation of Reactor Building Ventilation was still available.
"Currently, refueling operations are stopped until auto-isolation of Reactor Building Ventilation is restored."
The licensee has determined that no increased gaseous or particulate radiation levels existed while the auto-isolation features were defeated.
The licensee has notified the NRC Resident Inspector.
The following information was obtained from the licensee via facsimile:
"At 1630 [hrs CST] the control room was performing head lift and pre-rod drive unlatching checkout and discovered R-12 (Containment Radiation Monitor) would not isolate reactor ventilation isolation. Investigation found that work on Engineered Safeguards Features pre-startup logic test had defeated both Train A and B automatic isolation signals to [Reactor Building Ventilation]. This test was started and signals defeated at 0803 [hrs.] and 0804 [hrs.]. Refueling evolutions, upper internals lift and rod latching were performed. Technical Specifications require auto-isolation capability for [Reactor Building Ventilation] during refueling ops.
"Both R-12 and R-21 would respond to high radiation and manual isolation of Reactor Building Ventilation was still available.
"Currently, refueling operations are stopped until auto-isolation of Reactor Building Ventilation is restored."
The licensee has determined that no increased gaseous or particulate radiation levels existed while the auto-isolation features were defeated.
The licensee has notified the NRC Resident Inspector.