Event Notification Report for November 17, 2004

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
11/16/2004 - 11/17/2004

EVENT NUMBERS
41203412044121141273

Other Nuclear Material
Event Number: 41203
Rep Org: DEPARTMENT VETERANS AFFAIRS
Licensee: DEPARTMENT VETERANS AFFAIRS
Region: 1
City: SALEM   State: VA
County:
License #: 03-23853-01VA
Agreement: N
Docket:
NRC Notified By: GARY WILLIAMS
HQ OPS Officer: JOHN MacKINNON
Notification Date: 11/17/2004
Notification Time: 15:22 [ET]
Event Date: 11/17/2004
Event Time: 12:00 [EST]
Last Update Date: 11/17/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
20.1906(d)(1) - SURFACE CONTAM LEVELS > LIMITS
Person (Organization):
KENNETH JENISON (R1)
KENNETH RIEMER (R3)
LINDA GERSEY (NMSS)
Event Text
REMOVABLE RADIOACTIVE SURFACE CONTAMINATION

Department of Veterans Affairs, National Health Physics Program report the following information:

"I am calling to report packages that exceeded the limits for removable radioactive surface contamination. The packages were received between 0700 to 1200, November 17, 2004, by the permittee (VA Medical Center, Salem, Virginia) authorized under the master license issued to the Department of Veterans Affairs, NRC License 03-23853-01VA.

"The basis for reporting the loss is under 10 CFR 20.1906(d)(1) in that the packages, ammo boxes being used to deliver radioactive materials, had approximately 28, 70, and 110 DPM per centimeter squared removable radioactive contamination on the outside.

"The contamination was identified as Technetium-99M.

"The Cardinal Health Nuclear Pharmacy Services delivered the packages. The status of whether the vendor delivery vehicle was exclusive use was not determined.

"The permittee Radiation Safety Officer notified the vendor about the package and has taken appropriate health and safety steps to prevent any possible spread of contamination."


Power Reactor
Event Number: 41204
Facility: PRAIRIE ISLAND
Region: 3     State: MN
Unit: [] [2] []
RX Type: [1] W-2-LP,[2] W-2-LP
NRC Notified By: TODD STRAIN
HQ OPS Officer: BILL HUFFMAN
Notification Date: 11/17/2004
Notification Time: 23:46 [ET]
Event Date: 11/17/2004
Event Time: 20:50 [CST]
Last Update Date: 11/18/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - PLANT S/D REQD BY TS
Person (Organization):
JAMES CREED (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 0 Hot Standby
Event Text
TECHNICAL SPECIFICATION REQUIRED SHUT DOWN DUE TO BOTH TRAINS OF CONTAINMENT COOLING SYSTEM FAN COIL UNITS INOPERABLE

"Initiation of a Unit 2 shutdown commenced at 2050 on November 17, 2004, as required by Technical Specification (TS) Limiting Condition for Operation (LCO) 3.0.3 because both trains of containment cooling were declared inoperable as of 1615. Each train of Prairie Island's Containment Cooling System includes two containment fan coil units (CFCUs), for a total of four CFCUs. TS 3.6.5 requires two trains of containment cooling to be operable. Leakage from the 23 CFCU was determined to render one train of containment cooling inoperable at 1551. At 1615, the 22 CFCU (one of two CFCUs in the opposite train of containment cooling) was also determined to be leaking rendering the second train of containment cooling inoperable. Two CFCUs are fully capable of removing the design basis heat load; however, as the two remaining operable CFCUs are in different trains, neither train of containment cooling could be considered operable. Both inoperable CFCUs have been isolated to restore containment integrity and facilitate repairs. TS LCO 3.6.5 does not have a Condition for both containment cooling trains inoperable, therefore TS LCO 3.0.3 was entered."

The licensee has notified the NRC Resident Inspector.


Other Nuclear Material
Event Number: 41211
Rep Org: US ARMY
Licensee: US ARMY
Region: 3
City: ROCK ISLAND   State: IL
County:
License #: 12-00722-06
Agreement: Y
Docket:
NRC Notified By: THOMAS GIZICKI
HQ OPS Officer: STEVE SANDIN
Notification Date: 11/19/2004
Notification Time: 15:08 [ET]
Event Date: 11/17/2004
Event Time: 12:00 [CST]
Last Update Date: 11/19/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
30.50(b)(1) - UNPLANNED CONTAMINATION
Person (Organization):
JAMES CREED (R3)
SCOTT MOORE (NMSS)
ANTHONY DIMITRIADIS (R1)
Event Text
UNPLANNED CONTAMINATION DUE TO A BROKEN M1A1 COLLIMATOR

During an exercise conducted in May 2004 at Camp Shelby, MS an M1A1 Collimator, NSN 1240-00-332-1780, containing 10 Curies Tritium was removed from service, i.e., possibly broken, and double-bagged for storage. The device was subsequently transported from Camp Shelby to Shelbyville, TN and ultimately forwarded to the Combined Support Maintenance Shop of the TN National Guard located in Smyrna, TN for repair. A routine pre-maintenance wet swipe test indicated contamination levels as high as 619,094 disintegrations/min using a liquid scintillation meter. This corresponds to an activity of 0.27 microcuries. Two TN National Guard staff have submitted samples for bioassay. The results will be available on Monday, 11/22. Radiation surveys conducted at the Shelbyville and Smyrna, TN storage locations were negative.

The device is currently double-bagged in the low level rad waste storage area of the Combined Support Maintenance Shop awaiting disposal.


General Information or Other
Event Number: 41273
Rep Org: LOUISIANA RADIATION PROTECTION DIV
Licensee: CENTRAL TESTING
Region: 4
City: SULPHUR   State: LA
County:
License #: LA-2293-L01
Agreement: Y
Docket:
NRC Notified By: SCOTT BLACKWELL
HQ OPS Officer: JEFF ROTTON
Notification Date: 12/21/2004
Notification Time: 09:45 [ET]
Event Date: 11/17/2004
Event Time: 00:00 [CST]
Last Update Date: 12/21/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
BLAIR SPITZBERG (R4)
SANDRA WASTLER (NMSS)
Event Text
AGREEMENT STATE EQUIPMENT MALFUNCTION

The following report was received via facsimile:

"Central Testing Company had a camera malfunction on November 17, 2004. When the radiographer tried to crank out the source to make his first exposure he realized that the camera would not allow him to. He notified Central Testing of the problem. The camera was returned to SPEC and they replaced the locking mechanism on the camera. The camera is now functioning properly."

LA Event Report ID - LA040013