Event Notification Report for November 04, 2004
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
11/03/2004 - 11/04/2004
Power Reactor
Event Number: 41263
Facility: PALISADES
Region: 3 State: MI
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: BARB DOTSON
HQ OPS Officer: BILL GOTT
Region: 3 State: MI
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: BARB DOTSON
HQ OPS Officer: BILL GOTT
Notification Date: 12/15/2004
Notification Time: 09:36 [ET]
Event Date: 11/04/2004
Event Time: 09:17 [EST]
Last Update Date: 12/15/2004
Notification Time: 09:36 [ET]
Event Date: 11/04/2004
Event Time: 09:17 [EST]
Last Update Date: 12/15/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.73(a)(1) - INVALID SPECIF SYSTEM ACTUATION
10 CFR Section:
50.73(a)(1) - INVALID SPECIF SYSTEM ACTUATION
Person (Organization):
ROGER LANKSBURY (R3)
ROGER LANKSBURY (R3)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Refueling | 0 | Refueling |
INVALID SYSTEM ACTUATION - SAFETY INJECTION
On November 4, 2004, at 0917 hours EST, an inadvertent actuation of the left train of the safety injection system was initiated. The invalid actuation occurred during a system surveillance test, when a screwdriver that was being used to lift a lead slipped, causing a short circuit between the terminal being disconnected, and an energized terminal directly in front of it. As a result, all left train safety injection system equipment activated as expected for existing plant conditions.
The resident inspector was notified of this event.
On November 4, 2004, at 0917 hours EST, an inadvertent actuation of the left train of the safety injection system was initiated. The invalid actuation occurred during a system surveillance test, when a screwdriver that was being used to lift a lead slipped, causing a short circuit between the terminal being disconnected, and an energized terminal directly in front of it. As a result, all left train safety injection system equipment activated as expected for existing plant conditions.
The resident inspector was notified of this event.
Power Reactor
Event Number: 41173
Facility: PERRY
Region: 3 State: OH
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: RICK WILES
HQ OPS Officer: JEFF ROTTON
Region: 3 State: OH
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: RICK WILES
HQ OPS Officer: JEFF ROTTON
Notification Date: 11/04/2004
Notification Time: 11:11 [ET]
Event Date: 11/04/2004
Event Time: 10:54 [EST]
Last Update Date: 11/04/2004
Notification Time: 11:11 [ET]
Event Date: 11/04/2004
Event Time: 10:54 [EST]
Last Update Date: 11/04/2004
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
Person (Organization):
SONIA BURGESS (R3)
TERRY REIS (EO)
RICHARD WESSMAN (IRD)
JANNIE EVERETTE (DHS)
AUSTIN (FEMA)
SONIA BURGESS (R3)
TERRY REIS (EO)
RICHARD WESSMAN (IRD)
JANNIE EVERETTE (DHS)
AUSTIN (FEMA)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
UNUSUAL EVENT DECLARED DUE TO A TOXIC GAS RELEASE AFFECTING NORMAL OPERATIONS
At 1054 EST on 11/04/04, the licensee declared an Unusual Event due to an acidic water spray in the Water Treatment Building affecting normal access. Licensee entered EAL MU-1, Toxic Gas detected within the Protected Area that impacts normal operations. There were two personnel in the building at the time of the leak, one Non-licensed operator and his supervisor. The Non-licensed operator was overcome by fumes and became nauseous and was taken to the onsite dispensary. The non-licensed operator was treated and taken to the local hospital. The supervisor did not seem to be affected, but he has been taken to the onsite dispensary for any necessary treatment.
No unplanned release has occurred and no protective action recommendations are applicable at this time. The acidic water spray made contact with a 480 Vac panel in the building and has caused an electrical ground. Equipment in the building that may potentially affect plant operation if damaged are the clearwell pumps. The clearwell pumps supply seal water for the Main Circulating water pumps, and the non vital service water pumps.
The licensee notified the NRC Resident Inspector and made all state and local government emergency management notifications.
* * * Update on 11/04/04 at 1338 EST by Rick Wiles taken by MacKinnon * * *
Atmospheric conditions in the area have been confirmed to be normal. Slippery conditions and acid hazard still exist on the floor. Licensee is still in an Unusual Event. NRC Resident Inspector has been notified of this update. R3DO (S. Burgess) notified.
* * * Update on 11/04/04 at 1512 EST by Rick Wiles taken by MacKinnon * * *
Unusual Event terminated at 1502 EST. Surrounding Counties and the State of Ohio were notified by the licensee that the Unusual Event was terminated. NRC Resident Inspector notified of the termination of the Unusual Event. R3DO (Sonia Burgess), NRR EO (Terry Reis), IRD (Dick Wessman), FEMA (Austin) and DHS (Lee) notified.
At 1054 EST on 11/04/04, the licensee declared an Unusual Event due to an acidic water spray in the Water Treatment Building affecting normal access. Licensee entered EAL MU-1, Toxic Gas detected within the Protected Area that impacts normal operations. There were two personnel in the building at the time of the leak, one Non-licensed operator and his supervisor. The Non-licensed operator was overcome by fumes and became nauseous and was taken to the onsite dispensary. The non-licensed operator was treated and taken to the local hospital. The supervisor did not seem to be affected, but he has been taken to the onsite dispensary for any necessary treatment.
No unplanned release has occurred and no protective action recommendations are applicable at this time. The acidic water spray made contact with a 480 Vac panel in the building and has caused an electrical ground. Equipment in the building that may potentially affect plant operation if damaged are the clearwell pumps. The clearwell pumps supply seal water for the Main Circulating water pumps, and the non vital service water pumps.
The licensee notified the NRC Resident Inspector and made all state and local government emergency management notifications.
* * * Update on 11/04/04 at 1338 EST by Rick Wiles taken by MacKinnon * * *
Atmospheric conditions in the area have been confirmed to be normal. Slippery conditions and acid hazard still exist on the floor. Licensee is still in an Unusual Event. NRC Resident Inspector has been notified of this update. R3DO (S. Burgess) notified.
* * * Update on 11/04/04 at 1512 EST by Rick Wiles taken by MacKinnon * * *
Unusual Event terminated at 1502 EST. Surrounding Counties and the State of Ohio were notified by the licensee that the Unusual Event was terminated. NRC Resident Inspector notified of the termination of the Unusual Event. R3DO (Sonia Burgess), NRR EO (Terry Reis), IRD (Dick Wessman), FEMA (Austin) and DHS (Lee) notified.