Skip to main content

Event Notification Report for October 13, 2004

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
10/12/2004 - 10/13/2004

EVENT NUMBERS
4111842780

Power Reactor
Event Number: 41118
Facility: SALEM
Region: 1     State: NJ
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: RICK DESANCTIS
HQ OPS Officer: BILL HUFFMAN
Notification Date: 10/13/2004
Notification Time: 19:14 [ET]
Event Date: 10/13/2004
Event Time: 15:41 [EDT]
Last Update Date: 10/13/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
BRIAN MCDERMOTT (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
REACTOR COOLANT LEAKAGE OUTSIDE CONTAINMENT EXCEEDING FINAL SAFETY ANALYSIS LIMITS

"This is all 8 hour notification being made to report exceeding the design basis for the reactor coolant leakage outside of containment. The event is being reported under paragraph (b)(3)(v) of 10 CFR 50.72.

"On 10/13/04 at 1541, the control room was notified that tight system isolation boundaries could not be achieved on the 23 Charging pump [positive displacement pump]. The pump was tagged to support maintenance. Although the leak rate has not been quantified, it is suspected that it was greater than the UFSAR limit for ECCS leakage outside containment.

"With leakage greater than the UFSAR allowed limits (greater than 3840 cc/hr), GDC-19 limits for control room habitability cannot be assured.

"Actions have been completed to restore system integrity. The affected positive displacement charging pump is not a safety related pump and is not required for accident mitigation; however it is exposed to the ECCS recirculation flow path during the cold leg injection phase of the accident mitigation.

"The licensee has notified the NRC Resident Inspector of this event. The local township will also be notified."

The licensee stated that the leakage has been isolated; there was no indication of an increase in radiation levels during the leakage; and that the duration of the leakage was approximately 3 hours.


General Information or Other
Event Number: 42780
Rep Org: MA RADIATION CONTROL PROGRAM
Licensee: NITRON CORPORATION
Region: 1
City: BILLERICA   State: MA
County:
License #: 55-0238
Agreement: Y
Docket:
NRC Notified By: JOHN SUMARES
HQ OPS Officer: BILL HUFFMAN
Notification Date: 08/16/2006
Notification Time: 09:58 [ET]
Event Date: 10/13/2004
Event Time: 00:00 [EDT]
Last Update Date: 08/16/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RAYMOND LORSON (R1)
CINDY FLANNERY (NMSS)
Event Text
MASSACHUSETTES AGREEMENT STATE REPORT OF LEAKING FE-55

The State provided the following information regarding a previously unreported event via facsimile:

"On October 15, 2004, Niton Corporation provided a report of a leaking sealed source that was discovered by Niton on October 13, 2004, during routine maintenance of a customer's model Xli 868p XRF device, S/N 5043. The sealed source is AEA Technology model IEC.A1, S/N 8765LG containing 10.3 mCi of Fe-55. The estimated leakage was 700,000 dpm or 0.3 microcuries.

"The source and a few contaminated device components were removed from the device and placed into a waste storage container. The area where the source removal was performed was surveyed and no contamination was found. The source manufacturer, AEA Technology, was notified of the leaking source. The source manufacturer, AEA Technology, has re-designed the source."

The cause and corrective action were determined and this event is considered closed by the Agency.