Event Notification Report for October 02, 2004

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
10/01/2004 - 10/02/2004

EVENT NUMBERS
410844108541091

!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 41084
Facility: PERRY
Region: 3     State: OH
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: ROBERT KIDDER
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 10/02/2004
Notification Time: 15:22 [ET]
Event Date: 10/02/2004
Event Time: 13:00 [EDT]
Last Update Date: 10/25/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
THOMAS KOZAK (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
PLANT DECLARED THE EMERGENCY RECIRCULATION VENTILATION SYSTEM INOPERABLE.

A surveillance test was being performed on the Emergency Recirc vent System and all six dampers on both trains failed to stroke in the required Tech. Spec. times. Therefore, both trains of the Emergency Recirc Vent System were declared inoperable and the plant entered T.S. 3.0.3. The LCO action statement requires the plant to be in mode 2 in 7 hours and mode 3 in the following six hours and mode 4 in the following 24 hours. They are currently troubleshooting the problem.

The NRC resident Inspector was notified

HOO Note: see event 41085

* * * UPDATE ON 10/02/04 AT 1940 EDT FROM FREDERICK SMITH TO GERRY WAIG * * *

"Update to [Event] Notifications 41084 and 41085:
At 1840 [EDT] on 10/02/04 it was determined that the apparent slow response times of the Control Room Emergency Recirculation [CRER] dampers was due to a malfunctioning relay in the initiation circuit, not due to failure of the dampers. The LCO actions associated with the CRER system were exited and the actions associated with the initiation instrument were entered. Therefore the plant is no longer required to shutdown per T.S. 3.0.3. The plant shutdown has been terminated. Plant power will be returned to 100%."

The licensee has notified the NRC resident Inspector.

Notified R3DO (Thomas Kozak).

* * * RETRACTION FROM KEN MEADE TO BILL HUFFMAN ON 10/25/04 AT 1433 EDT * * *

"At 1300 on 10/02/04, results of a surveillance indicated that dampers in both trains of the Control Room Emergency Recirculation System (CRERS) were slower than allowed by Technical Specifications (TS) requiring both trains of the CRERS to be declared inoperable. With both trains inoperable, Technical Specification 3.0.3 was entered which required a plant shutdown. The shutdown was commenced at 1500. This condition was reported as required in Event Notification 41085. Additionally, with both CRERS trains inoperable, this condition was determined to be reportable as a loss of safety function (accident mitigation) and was reported as required in Event Notification 41084.

"Subsequently, it was determined that the failure was the result of a defective time delay relay in the radiation monitor initiation circuit. Other inputs that would have caused the dampers to reposition in an accident were not impacted. The appropriate TS (3.3.7.1), for the radiation monitor, was entered and TS 3.0.3 was exited. The significant actions required by this TS were to restore the function within 7 days or place the system in emergency recirculation. It did not require entry into an action to shutdown. When this condition was identified, TS 3.0.3 was exited, the shutdown was terminated, and the plant was restored to full power. Since a TS required shutdown was not required, Event Notification 41085 is being retracted.

"The condition was also reported as a loss of safety function for the accident mitigation function of CRERS. The CRERS is automatically activated by a Loss of Coolant Accident (LOCA) signal or a Control Room Ventilation (CRV) high radiation signal. The LOCA instrumentation circuitry was not affected by the defective time delay relay and thus the damper stroke times were not impacted. The CRV airborne radiation monitor signal is considered a "diverse" signal to the LOCA signal. Since the LOCA signal would have properly initiated the CRERS and the CRV high radiation signal is redundant, there was no loss of safety function. Since there was no loss of safety function, Event Notification 41084 is being retracted."

The licensee has notified the NRC Resident Inspector. NRC R3DO(Gardner) has been notified.


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 41085
Facility: PERRY
Region: 3     State: OH
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: ROBERT KIDDER
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 10/02/2004
Notification Time: 15:22 [ET]
Event Date: 10/02/2004
Event Time: 15:00 [EDT]
Last Update Date: 10/25/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - PLANT S/D REQD BY TS
Person (Organization):
THOMAS KOZAK (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 83 Power Operation
Event Text
REACTOR POWER BEING REDUCED DUE TO ENTERING TS 3.0.3 BECAUSE OF INOPEABLE RECIRC VENT SYSTEM

At 1500 hours the plant commenced reactor shutdown from 100% power for entering T.S. 3.0.3 due to both trains of the Emergency Recirc Vent System being declared inoperable. The reactor will be in mode 2 by 2000 hours, mode 3 by 0200 hours on 10/03 and mode 4 by 0200 hours on 10/04. If the problem is corrected, they will terminate the shutdown.

The NRC Resident Inspector was notified.

HOO Note: see event 41084

* * * UPDATE ON 10/02/04 AT 1940 EDT FROM FREDERICK SMITH TO GERRY WAIG * * *

"Update to [Event] Notifications 41084 and 41085:
At 1840 [EDT] on 10/02/04 it was determined that the apparent slow response times of the Control Room Emergency Recirculation [CRER] dampers was due to a malfunctioning relay in the initiation circuit, not due to failure of the dampers. The LCO actions associated with the CRER system were exited and the actions associated with the initiation instrument were entered. Therefore the plant is no longer required to shutdown per T.S. 3.0.3. The plant shutdown has been terminated. Plant power will be returned to 100%."

The licensee has notified the NRC resident Inspector.

Notified R3DO (Thomas Kozak).

* * * RETRACTION FROM KEN MEADE TO BILL HUFFMAN ON 10/25/04 AT 1433 EDT * * *

"At 1300 on 10/02/04, results of a surveillance indicated that dampers in both trains of the Control Room Emergency Recirculation System (CRERS) were slower than allowed by Technical Specifications (TS) requiring both trains of the CRERS to be declared inoperable. With both trains inoperable, Technical Specification 3.0.3 was entered which required a plant shutdown. The shutdown was commenced at 1500. This condition was reported as required in Event Notification 41085. Additionally, with both CRERS trains inoperable, this condition was determined to be reportable as a loss of safety function (accident mitigation) and was reported as required in Event Notification 41084.

"Subsequently, it was determined that the failure was the result of a defective time delay relay in the radiation monitor initiation circuit. Other inputs that would have caused the dampers to reposition in an accident were not impacted. The appropriate TS (3.3.7.1), for the radiation monitor, was entered and TS 3.0.3 was exited. The significant actions required by this TS were to restore the function within 7 days or place the system in emergency recirculation. It did not require entry into an action to shutdown. When this condition was identified, TS 3.0.3 was exited, the shutdown was terminated, and the plant was restored to full power. Since a TS required shutdown was not required, Event Notification 41085 is being retracted.

The licensee has notified the NRC Resident Inspector. NRC R3DO(Gardner) has been notified.


General Information or Other
Event Number: 41091
Rep Org: CALIFORNIA RADIATION CONTROL PRGM
Licensee: TEICHERT CONSTRUCTION
Region: 4
City: TRACEY   State: CA
County:
License #: 4030
Agreement: Y
Docket:
NRC Notified By: ED GLOOR
HQ OPS Officer: JOHN MacKINNON
Notification Date: 10/04/2004
Notification Time: 18:16 [ET]
Event Date: 10/02/2004
Event Time: 00:00 [PDT]
Last Update Date: 10/04/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RUSSELL BYWATER (R4)
M. WAYNE HODGES (NMSS)
MEXICO (via fax)
Event Text
AGREEMENT STATE REPORT INVOLVING A STOLEN TROXLER GAUGE

The State of CA was notified at 0830 hrs [PDT] on 10/04/04 of a reported stolen Troxler 3241C 100 microCuries Am 241/Be gauge, SN # 1537. The theft occurred from a construction jobsite over the weekend. Bolt cutters were used in the theft. Local police have been notified and a cash reward is being offered.

NMED # XCA598.