Event Notification Report for October 01, 2004

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
09/30/2004 - 10/01/2004

EVENT NUMBERS
410824108341087410904109641124

Power Reactor
Event Number: 41082
Facility: RIVER BEND
Region: 4     State: LA
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: DANNY WILLIAMSON
HQ OPS Officer: BILL HUFFMAN
Notification Date: 10/01/2004
Notification Time: 12:00 [ET]
Event Date: 10/01/2004
Event Time: 07:30 [CDT]
Last Update Date: 10/01/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(A) - ECCS INJECTION 50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL
Person (Organization):
LINDA HOWELL (R4)
BOB DENNIG (NREO)
HO NIEH (IRO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 A/R Y 100 Power Operation 0 Hot Shutdown
Event Text
REACTOR TRIP DUE TO MAIN GENERATOR LOAD REJECTION

"At 7:30 a.m. [CDT] on October 1, 2004, an automatic reactor scram occurred as a result of an electrical fault on the main generator output lines that caused a main generator trip and turbine trip. All control rods inserted. Approximately 13 minutes prior to the fault, a loss of one station service transformer had occurred. This resulted in an automatic start of the Division 1 diesel generator and a loss of power to some plant auxiliaries, including the feedwater level regulation isolation valves.

"The loss of reserve station service no. 1, combined with the trip of the main generator, caused a loss of power to two condensate pumps and one main feedwater pump. The remaining two feedwater pumps tripped on low suction pressure. The reactor containment isolation cooling pump (RCIC) steam supply isolated during the scram transient, so the control room operators manually started the high-pressure core spray system (HPCS) pump for level control. The injection valve was closed as level had already reached the high water level isolation setpoint for that valve. It was later reopened manually as level approached the low level setpoint (level 2), which would have automatically opened the valve. The level 2 setpoint was reached briefly after the valve was already open.

"Reactor pressure is being controlled manually with safety relief valves (SRV's). The main steam isolation valves (MSIV's) were manually closed due to lowering pressure from steam loads in the plant that could not be immediately isolated because of loss of power to their valves. RCIC is also running in CST (condensate storage tank) to CST mode, to augment pressure control.

"The electrical load center which supplies power to the instrumentation and valves needed for feedwater operation was cross-tied to an alternate power source, and feedwater was restored to operation and is presently controlling reactor water level. During the event, standby service water also initiated.

"This is the presently known information. Further information will be provided as the investigation continues."

The licensee has notified the NRC Resident Inspector.


Power Reactor
Event Number: 41083
Facility: TURKEY POINT
Region: 2     State: FL
Unit: [3] [] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: BARROW
HQ OPS Officer: BILL HUFFMAN
Notification Date: 10/01/2004
Notification Time: 16:30 [ET]
Event Date: 10/01/2004
Event Time: 14:15 [EDT]
Last Update Date: 10/01/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
ROBERT HAAG (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N N 0 Refueling 0 Refueling
Event Text
DEATH OF A CONTRACT EMPLOYEE FROM AN APPARENT HEART ATTACK

The following was received from the licensee via facsimile:

"A 56-year old male AREVA contractor died from a heart attack. A report of potential heart attack was made at 1242 [EDT] to the control room. Off-site medical assistance was used and the contractor was transported to South Miami-Homestead Hospital at 1340 [EDT]. [The] contractor was pronounced dead at 1415 [EDT]."

The licensee also reported that the individual was not contaminated and was stricken while working in a contractor trailer located near the facility administration building.

The licensee has notified the NRC Resident Inspector and will be notifying the Occupational Safety Health Administration (OSHA).


General Information or Other
Event Number: 41087
Rep Org: UTAH DIVISION OF RADIATION CONTROL
Licensee: MOUNTAIN VIEW HOSPITAL
Region: 4
City: Payson   State: UT
County:
License #: UT 2500098
Agreement: Y
Docket:
NRC Notified By: JULIE R. FELICE
HQ OPS Officer: JOHN MacKINNON
Notification Date: 10/04/2004
Notification Time: 14:25 [ET]
Event Date: 10/01/2004
Event Time: 07:30 [MDT]
Last Update Date: 10/04/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RUSSELL BYWATER (R4)
SANDRA WASTLER (NMSS)
Event Text
AGREEMENT STATE REPORT FROM THE STATE OF UTAH

"The licensee's technologist accidentally administered a 400 mCi bulk dose of Tc-99m (sodium pertecthnetate) instead of 4 mCi of Cardiolite. The licensee took a number of steps to protect the patient. They administered a thyroid blocker, and they administered IV fluids and oral fluids to the patient to help flush the Tc-99m. According to the licensee's consultant, the patient received an 80 rad dose to the GI tract.

"The Utah Division of Radiation Control was notified by the licensee on Friday, October 1, 2004, at approximately 10:18 a.m. MST.

"The licensee notified the following: The patient, the referring physician, the Radiation Safety Officer, the Authorized User on site, the nuclear pharmacy, and a consultant."

Utah Report ID No: UT-04-003


Fuel Cycle Facility
Event Number: 41090
Facility: BATTELLE MEMORIAL INSTITUTE
Region: 3     State: OH
Unit: [] [] []
RX Type: ADVANCED FUEL R&D AND PILOT PLANTS
NRC Notified By: JOE JACOBSEN
HQ OPS Officer: JOHN MacKINNON
Notification Date: 10/04/2004
Notification Time: 17:50 [ET]
Event Date: 10/01/2004
Event Time: 11:00 [EDT]
Last Update Date: 10/04/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
21.21 - UNSPECIFIED PARAGRAPH
Person (Organization):
PATRICK LOUDEN (R3)
M. WAYNE HODGES (NMSS)
ROBERTO TORRES (NMSS)
Event Text
CRACKS/FISSURES IN POWER AIR PURIFYING RESPIRATORS (PAPR) MOTOR/BLOWER ASSEMBLY CASINGS



"Exact content of notification: Battelle is notifying NRC of a potential defect as from the manufacturer
concerning the MSA equipment provided Model MM2K PAPR motor/blower assembly (Part 10022695). After limited field use at its West Jefferson, Ohio site noticeable cracks/fissures developed on some of the motor/blower casings. The manufacturer of the equipment, MSA, has been notified of the problem and several of the cracked/fissure units have been returned to MSA for testing in early September. Battelle discontinued use of the MSA Model MM2K PAP'R in mid September as a result of the observed equipment cracks/fissures at its West Jefferson, Ohio site.

"Describe the event: We have been experiencing noticeable cracks/fissures of some of our MSA brand MM2K Powered Air Purifying Respirators (PAPR) motor/blower assembly casings (Part #10022695). We have not experienced any break through of the casings tied to employee exposure as evidenced by our In place personnel monitoring programs. Our original note of the circumstance was on August 25, 2004 during the re-use inspection process of the MSA MM2K PAPR by the Respiratory Protection Supervisor on site. We have field verified that our respirator cleaning and use processes are adequate and in line with the manufacturer recommendations. We again experienced a similar crack/fissures Issue with a different order of MSA MM2K PAPR motor/blower assemblies by a different vendor ordering from a different lot number in early September 2004. We have discontinued use of the MSA MM2K PAPR on site in mid September as a result of the issues we have had and have supplied MSA with several of the cracked/fissured MM2K PAPR motor/blower assembly casings for testing at their facility In Pennsylvania. MSA Is working on a solution for the identified issue.


General Information or Other
Event Number: 41096
Rep Org: NEW MEXICO RAD CONTROL PROGRAM
Licensee: RIVERSIDE TECHNOLOGIES
Region: 4
City: FAIRVIEW   State: NM
County: RIO ARRIBA
License #: DM345
Agreement: Y
Docket:
NRC Notified By: WALTER MEDINA
HQ OPS Officer: BILL GOTT
Notification Date: 10/06/2004
Notification Time: 10:28 [ET]
Event Date: 10/01/2004
Event Time: 00:00 [MDT]
Last Update Date: 10/12/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RUSSELL BYWATER (R4)
SANDRA WASTLER (NMSS)
Event Text
AGREEMENT STATE REPORT

"Riverside Technologies notified the Radiation Control Bureau with the New Mexico Environment Department that one of their density moisture gauges was stolen sometime between Friday night, October 1, and Monday morning, October 4,2004. The locked storage room was broken into and the gauge was removed from its transport container and taken from the company office in Espanola, New Mexico. The gauge was a Campbell Pacific Nuclear, Model MC-3, serial number M30069661, and containing Cesium-137 and Americium-241/Be radioactive sealed sources. The gauge was locked in the safe position."

* * * UPDATE AT 11:32 HRS. EDT ON 10/12/04 FROM MEDINA (VIA E-MAIL) TO CROUCH * * *

"The density/moisture gauge (CPN, model MC-3, SN 30069691) reported stolen by Riverside Technologies (NM license number DM345) on 10/4/2004 has been found. The RSO, [DELETED], called at 8:45 a.m. MST today and reported that the gauge had been left near his vehicle at his residence in Espanola. There is no apparent damage to the gauge and the source rod was still locked. The RSO will leak test the gauge to evaluate the integrity of the sources. This gauge was not being used and had been in storage since acquired from another licensee. The gauge will again be placed in storage with additional security measures being implemented at the facility."

Notified TAS (Hahn), R4DO (Kennedy) and NMSS EO (Wastler).


General Information or Other
Event Number: 41124
Rep Org: LOUISIANA RADIATION PROTECTION DIV
Licensee: TULANE UNIVERSITY
Region: 4
City: NEW ORLEANS   State: LA
County:
License #: LA-0004-L01
Agreement: Y
Docket:
NRC Notified By: SCOTT BLACKWELL
HQ OPS Officer: BILL GOTT
Notification Date: 10/15/2004
Notification Time: 11:08 [ET]
Event Date: 10/01/2004
Event Time: 00:00 [CDT]
Last Update Date: 10/15/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
KRISS KENNEDY (R4)
TOM ESSIG (NMSS)
Event Text
AGREEMENT STATE - MEDICAL EVENT

"This incident took place on October 1, 2004. A patient from Room 5206 was administered 20 millicuries of Xe-133 gas resulting in a lung dose of 0.22 Rad and an Effective Dose Equivalent of 0.028 Rad. It was then found that the orders were written for a patient in Room 5213. The order form had the wrong patient name sticker attached. The nursing station supervisor stated that they had noticed incorrect patient name stickers in the Room 5213 patient chart. It is not known how these stickers and chart orders were switched. The patient was notified of the error and the correct patient later received the Xenon scan."

Event Report: LA040012