Skip to main content

Event Notification Report for September 19, 2004

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
09/18/2004 - 09/19/2004

EVENT NUMBERS
410604105441056

General Information or Other
Event Number: 41060
Rep Org: FLORIDA BUREAU OF RADIATION CONTROL
Licensee: UNIVERSAL ENGINEERING SCIENCES, INC
Region: 1
City: SARASOTA   State: FL
County:
License #: 1136-6
Agreement: Y
Docket:
NRC Notified By: CHARLES ADAMS
HQ OPS Officer: BILL HUFFMAN
Notification Date: 09/21/2004
Notification Time: 11:17 [ET]
Event Date: 09/19/2004
Event Time: 00:00 [EDT]
Last Update Date: 09/21/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JOHN CARUSO (R1)
TOM ESSIG (NMSS)
Event Text
AGREEMENT STATE REPORT OF DAMAGE TO SOIL MOISTURE DENSITY GAUGE

The following information was provided to the NRC from the Florida Bureau of Radiation Control via e-mail.

A Troxler soil moisture density gauge (Model #3411-B; Serial #8598) was damaged when it was run over by a front end loader. The source rod was broken off and the cesium source was detached from the rod. Investigators searched and recovered the source. The gauge and source will be sent to Troxler for repair. No further action will be taken on this incident.

The Troxler source strength is 8 millicuries Cesium-137 and 40 millicuries Americium/Beryllium.

There were no personnel exposures.


Power Reactor
Event Number: 41054
Facility: WATTS BAR
Region: 2     State: TN
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: RICK O REAR
HQ OPS Officer: GERRY WAIG
Notification Date: 09/19/2004
Notification Time: 07:46 [ET]
Event Date: 09/19/2004
Event Time: 04:56 [EDT]
Last Update Date: 09/19/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
ANNE BOLAND (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 M/R Y 100 Power Operation 0 Hot Standby
Event Text
MANUAL REACTOR TRIP IN RESPONSE TO INDICATION OF DROPPED CONTROL RODS

The following was received from the licensee via facsimile:

"While operating at 100% power, the Watts Bar Unit 1 reactor was manually tripped at approximately 0456 EDT on September 19, 2004, in response to an apparent four dropped rods in control bank 'B'. The cause of the dropped rods is being investigated.

"Safety systems functioned as expected in response to the trip. All control rods inserted properly in response to the reactor trip. The Auxiliary Feedwater (AFW) System actuated as designed in response to the trip. One reactor coolant pump (RCP) did not transfer to its alternate power supply.

"The manual actuation of the Reactor Protection System (RPS) is being reported as a four hour report under 10 CFR 50.72 (b)(2)(iv). The actuation of the Auxiliary Feedwater System (an engineered safety feature) is being reported as an eight hour report under 10 CFR 50.72 (b)(3)(iv). Notification to NRC was made by Rick O'Rear at 0744 EDT.

"The NRC Senior Resident Inspector was notified of this event."

The licensee also reported that the reactor is being maintained at the normal temperature and pressure for this condition. All station service electrical systems and the emergency diesel generators are available and in normal configuration. All emergency core cooling systems are available. Decay heat is being removed using steam dump to the main condenser and feedwater to the steam generators is being provided by the electric main feedwater pump.


Power Reactor
Event Number: 41056
Facility: ARKANSAS NUCLEAR
Region: 4     State: AR
Unit: [1] [2] []
RX Type: [1] B&W-L-LP,[2] CE
NRC Notified By: CRYSTAL GARBE
HQ OPS Officer: BILL GOTT
Notification Date: 09/19/2004
Notification Time: 12:03 [ET]
Event Date: 09/19/2004
Event Time: 09:34 [CDT]
Last Update Date: 09/19/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
ANTHONY GODY (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
OFFSITE NOTIFICATION DUE TO SIREN ACTIVATION

"At 0934 CDT on 9/19/2004, the Unit 1 and Unit 2 Control Rooms began receiving phone calls reporting an actuation of emergency sirens in the Russellville area. A phone call was made to the Arkansas Department of Health, who controls actuation of the sirens, and the reported that they had indications of the sirens alarming. They suspect that power fluctuations in the area led to the inadvertent alarms.

This report is being made in accordance with ANO Reporting Guidelines "News Release or Government Agency Notification" and 10CFR50.72(b)(2)(xi) since there was a notification of state/county agencies of inadvertent actuation of part of the public notifications."

The licensee notified the NRC Resident Inspector.