Event Notification Report for September 17, 2004
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
09/16/2004 - 09/17/2004
EVENT NUMBERS
410474104841049410504105141052
Power Reactor
Event Number: 41047
Facility: FT CALHOUN
Region: 4 State: NE
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: ERICK MATZKE
HQ OPS Officer: GERRY WAIG
Region: 4 State: NE
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: ERICK MATZKE
HQ OPS Officer: GERRY WAIG
Notification Date: 09/17/2004
Notification Time: 10:43 [ET]
Event Date: 09/17/2004
Event Time: 06:24 [CDT]
Last Update Date: 09/17/2004
Notification Time: 10:43 [ET]
Event Date: 09/17/2004
Event Time: 06:24 [CDT]
Last Update Date: 09/17/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
DALE POWERS (R4)
DALE POWERS (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
OFFSITE NOTIFICATION TO ARMY CORPS OF ENGINEERS
"Utilization of the Missouri river water in support of the dry cask storage (ISFSI) project by Hawkins Construction Company was done in violation of national permitting requirements. Two tubes were placed in the river connected to two pumps: One small line (about 2.5 in.) used to supply water for the cure wetting of the concrete pours and one large line (6-8 in.) connected to a large pump for filling of water trucks for dust suppression and other utility uses.
"The United States Army Corps of Engineers, who manages the river and its utilization, requires approval of such uses through a national permitting process.
"This condition was identified during a routine site and environs tour. The Omaha Public Power District environmental affairs group has contacted the Army Corps of Engineers on the issue. The use of Missouri river water by the contractor has been terminated. Another source of water will be used to complete the project."
The licensee informed the U.S. Army Corps of Engineers and the NRC Resident Inspector.
"Utilization of the Missouri river water in support of the dry cask storage (ISFSI) project by Hawkins Construction Company was done in violation of national permitting requirements. Two tubes were placed in the river connected to two pumps: One small line (about 2.5 in.) used to supply water for the cure wetting of the concrete pours and one large line (6-8 in.) connected to a large pump for filling of water trucks for dust suppression and other utility uses.
"The United States Army Corps of Engineers, who manages the river and its utilization, requires approval of such uses through a national permitting process.
"This condition was identified during a routine site and environs tour. The Omaha Public Power District environmental affairs group has contacted the Army Corps of Engineers on the issue. The use of Missouri river water by the contractor has been terminated. Another source of water will be used to complete the project."
The licensee informed the U.S. Army Corps of Engineers and the NRC Resident Inspector.
Power Reactor
Event Number: 41048
Facility: CATAWBA
Region: 2 State: SC
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: MICHAEL T LEE
HQ OPS Officer: GERRY WAIG
Region: 2 State: SC
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: MICHAEL T LEE
HQ OPS Officer: GERRY WAIG
Notification Date: 09/17/2004
Notification Time: 11:31 [ET]
Event Date: 09/17/2004
Event Time: 10:00 [EDT]
Last Update Date: 09/17/2004
Notification Time: 11:31 [ET]
Event Date: 09/17/2004
Event Time: 10:00 [EDT]
Last Update Date: 09/17/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(ii)(A) - DEGRADED CONDITION
10 CFR Section:
50.72(b)(3)(ii)(A) - DEGRADED CONDITION
Person (Organization):
ANNE BOLAND (R2)
TERRY REIS (NRR)
ANNE BOLAND (R2)
TERRY REIS (NRR)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | N | 0 | Refueling | 0 | Refueling |
APPARENT PRESSURE BOUNDARY LEAKAGE IDENTIFIED ON STEAM GENERATOR BOWL DRAINS
"On September 16, 2004 examinations of the steam generator (SG) bowl drains (SGBDs) for the 2A, 2C and 2D SGs were performed as part of the Alloy 600 program during 2EOC13. These examinations determined that the 2C and 2D SGBDs had leakage and the leakage appeared to be pressure boundary leakage. The 2A SGBD examination determined that the ASME code acceptance limits were satisfied. An evaluation of the leakage indications determined that the leakage had existed for some time prior to the Unit 2 shutdown. The evaluation of this condition on September 17, 2004, determined that this met the reportability criteria of 10 CFR 50.72 (b)(3)(ii)(A). Unit 2 is currently in MODE 6 and this event has no impact on current plant operation. Engineering and plant management are evaluating repair methods to be completed during this refueling outage. This event is not applicable to Unit 1 because the Unit 1 steam generators are of a different design and do not have a drain line in the bottom channel head."
The licensee will notify the NRC Resident Inspector.
"On September 16, 2004 examinations of the steam generator (SG) bowl drains (SGBDs) for the 2A, 2C and 2D SGs were performed as part of the Alloy 600 program during 2EOC13. These examinations determined that the 2C and 2D SGBDs had leakage and the leakage appeared to be pressure boundary leakage. The 2A SGBD examination determined that the ASME code acceptance limits were satisfied. An evaluation of the leakage indications determined that the leakage had existed for some time prior to the Unit 2 shutdown. The evaluation of this condition on September 17, 2004, determined that this met the reportability criteria of 10 CFR 50.72 (b)(3)(ii)(A). Unit 2 is currently in MODE 6 and this event has no impact on current plant operation. Engineering and plant management are evaluating repair methods to be completed during this refueling outage. This event is not applicable to Unit 1 because the Unit 1 steam generators are of a different design and do not have a drain line in the bottom channel head."
The licensee will notify the NRC Resident Inspector.
Power Reactor
Event Number: 41049
Facility: WATTS BAR
Region: 2 State: TN
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: R. O'REAR
HQ OPS Officer: STEVE SANDIN
Region: 2 State: TN
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: R. O'REAR
HQ OPS Officer: STEVE SANDIN
Notification Date: 09/17/2004
Notification Time: 11:45 [ET]
Event Date: 09/17/2004
Event Time: 05:00 [EDT]
Last Update Date: 09/17/2004
Notification Time: 11:45 [ET]
Event Date: 09/17/2004
Event Time: 05:00 [EDT]
Last Update Date: 09/17/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION 50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION 50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
ANNE BOLAND (R2)
ANNE BOLAND (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
LOSS OF EMERGENCY SIREN CAPABILITY AND NOTIFICATION OF OFFSITE AGENCY
"On Sept. 17, 2004, with Watts Bar Unit 1 at 100% power, the main control room was notified that the 99 sirens which make up the Public Prompt Notification System were not functional. The system uses two repeaters to control the sirens. As the remnants of Hurricane Ivan were passing through the Tennessee River Valley one of the repeaters (Pone Knob) was found to be without power around midnight. The siren system operators confirmed the second repeater (Grandview) was still functioning. Approximately 5:00 a.m., however, communications were lost with the second repeater. A maintenance crew was dispatched to the second repeater on loss of communications and they determined the radio transmitter was not functioning at 0955 and Watts Bar was immediately notified. This event is reportable under 10 CFR 50.72(b)(3)(xiii) as a loss of emergency preparedness capability.
.
"As a result of the above siren loss, TVA notified the Tennessee Emergency Management Agency (TEMA) at 10:13a.m. Sept. 17, 2004. This government agency notification is reportable under 10 CFR 50.72(b)(2)(xi). No TVA press release is planned and TVA is not aware of any specific actions planned to be taken by TEMA. Maintenance activities to restore power to the first repeater station by the use of a portable generator are underway."
The 99 sirens constitute 100% of the emergency siren capability. The licensee had no estimate for completion of repairs and restoration of the siren capability. The licensee informed the State of Tennessee and the NRC Resident Inspector.
* * * * UPDATE FROM S. SMITH TO M. RIPLEY 1350 ET 09/17/04 * * * *
Restoration of power by use of a portable generator has been completed, reducing the number of non-functional sirens to seven of ninety-nine. The licensee informed local and State authorities, and the NRC Resident Inspector.
Notified R2 DO (A. Boland).
"On Sept. 17, 2004, with Watts Bar Unit 1 at 100% power, the main control room was notified that the 99 sirens which make up the Public Prompt Notification System were not functional. The system uses two repeaters to control the sirens. As the remnants of Hurricane Ivan were passing through the Tennessee River Valley one of the repeaters (Pone Knob) was found to be without power around midnight. The siren system operators confirmed the second repeater (Grandview) was still functioning. Approximately 5:00 a.m., however, communications were lost with the second repeater. A maintenance crew was dispatched to the second repeater on loss of communications and they determined the radio transmitter was not functioning at 0955 and Watts Bar was immediately notified. This event is reportable under 10 CFR 50.72(b)(3)(xiii) as a loss of emergency preparedness capability.
.
"As a result of the above siren loss, TVA notified the Tennessee Emergency Management Agency (TEMA) at 10:13a.m. Sept. 17, 2004. This government agency notification is reportable under 10 CFR 50.72(b)(2)(xi). No TVA press release is planned and TVA is not aware of any specific actions planned to be taken by TEMA. Maintenance activities to restore power to the first repeater station by the use of a portable generator are underway."
The 99 sirens constitute 100% of the emergency siren capability. The licensee had no estimate for completion of repairs and restoration of the siren capability. The licensee informed the State of Tennessee and the NRC Resident Inspector.
* * * * UPDATE FROM S. SMITH TO M. RIPLEY 1350 ET 09/17/04 * * * *
Restoration of power by use of a portable generator has been completed, reducing the number of non-functional sirens to seven of ninety-nine. The licensee informed local and State authorities, and the NRC Resident Inspector.
Notified R2 DO (A. Boland).
Power Reactor
Event Number: 41050
Facility: OCONEE
Region: 2 State: SC
Unit: [1] [2] [3]
RX Type: [1] B&W-L-LP,[2] B&W-L-LP,[3] B&W-L-LP
NRC Notified By: MARTY STASNY
HQ OPS Officer: BILL GOTT
Region: 2 State: SC
Unit: [1] [2] [3]
RX Type: [1] B&W-L-LP,[2] B&W-L-LP,[3] B&W-L-LP
NRC Notified By: MARTY STASNY
HQ OPS Officer: BILL GOTT
Notification Date: 09/17/2004
Notification Time: 12:19 [ET]
Event Date: 09/17/2004
Event Time: 10:30 [EDT]
Last Update Date: 09/17/2004
Notification Time: 12:19 [ET]
Event Date: 09/17/2004
Event Time: 10:30 [EDT]
Last Update Date: 09/17/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
ANNE BOLAND (R2)
ERIC WEISS (NSIR)
ANNE BOLAND (R2)
ERIC WEISS (NSIR)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 3 | N | Y | 100 | Power Operation | 100 | Power Operation |
LOSS OF SIREN CAPABILITY
"[Oconee is] unable to activate the siren system from the Oconee Law Enforcement Center due to the loss of power. The siren system can be activated from the backup location at Oconee Nuclear Station."
Oconee is working to restore power.
The licensee will notify the NRC Resident Inspector.
"[Oconee is] unable to activate the siren system from the Oconee Law Enforcement Center due to the loss of power. The siren system can be activated from the backup location at Oconee Nuclear Station."
Oconee is working to restore power.
The licensee will notify the NRC Resident Inspector.
Power Reactor
Event Number: 41051
Facility: CALVERT CLIFFS
Region: 1 State: MD
Unit: [1] [2] []
RX Type: [1] CE,[2] CE
NRC Notified By: BOB MARTIN
HQ OPS Officer: MIKE RIPLEY
Region: 1 State: MD
Unit: [1] [2] []
RX Type: [1] CE,[2] CE
NRC Notified By: BOB MARTIN
HQ OPS Officer: MIKE RIPLEY
Notification Date: 09/17/2004
Notification Time: 13:30 [ET]
Event Date: 09/17/2004
Event Time: 11:15 [EDT]
Last Update Date: 09/17/2004
Notification Time: 13:30 [ET]
Event Date: 09/17/2004
Event Time: 11:15 [EDT]
Last Update Date: 09/17/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
LAWRENCE DOERFLEIN (R1)
LAWRENCE DOERFLEIN (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
OFFSITE NOTIFICATION - COLIFORM BACTERIA FOUND IN DRINKING WATER
"Positive coliform in Eagles Den drinking water [unused, onsite building]. Confirmed by backup sample."
The licensee notified the Maryland Department of the Environment and the NRC Resident Inspector.
"Positive coliform in Eagles Den drinking water [unused, onsite building]. Confirmed by backup sample."
The licensee notified the Maryland Department of the Environment and the NRC Resident Inspector.
Fuel Cycle Facility
Event Number: 41052
Facility: BWX TECHNOLOGIES
Region: 2 State: VA
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
NRC Notified By: MYRTLE AKRES
HQ OPS Officer: MIKE RIPLEY
Region: 2 State: VA
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
NRC Notified By: MYRTLE AKRES
HQ OPS Officer: MIKE RIPLEY
Notification Date: 09/17/2004
Notification Time: 14:38 [ET]
Event Date: 09/17/2004
Event Time: 14:34 [EDT]
Last Update Date: 05/13/2008
Notification Time: 14:38 [ET]
Event Date: 09/17/2004
Event Time: 14:34 [EDT]
Last Update Date: 05/13/2008
Emergency Class: ALERT
10 CFR Section:
70.32(i) - EMERGENCY DECLARED
10 CFR Section:
70.32(i) - EMERGENCY DECLARED
Person (Organization):
ANNE BOLAND (R2)
BILL TRAVERS (R2)
TOM ESSIG (NMSS)
BETH HAYDEN (OPA)
PETE WILSON (NSIR)
ANNE BOLAND (R2)
BILL TRAVERS (R2)
TOM ESSIG (NMSS)
BETH HAYDEN (OPA)
PETE WILSON (NSIR)
ALERT DECLARED DUE TO TORNADO WARNINGS FOR CAMPBELL COUNTY, VIRGINIA
***********************************************************************************************************************************
THIS IS NOT A NEW REPORT.
This event report was originally withheld from public release under the NRC's policy for protecting sensitive unclassified information. The NRC has reevaluated this policy and is now making this event report available to the public with suitable redactions.
***********************************************************************************************************************************
Tornado Warnings were issued for Campbell County, Virginia and an Alert was declared at 1434 EDT. The facility activated its Emergency Operations Center, secured operations and materials, and subsequently sheltered employees. The NRC was not placed in a Response Mode.
Additional notifications: EPA/NRC (Melby), HHS (Roger)
* * * UPDATE AT 1521 EDT ON 09/17/04 FROM MYRTLE AKRES TO MIKE RIPLEY * * *
The Tornado Warnings were cancelled, and the Alert was terminated.
Notified RDO (Boland), NMSS EO (Essig), IRD Manager (Wilson), OC (Outlaw), PAO (Hayden), DHS, FEMA, DOE, EPA/NRC, USDA, and HHS.
* * * UPDATE ON 05/13/08 BY J.KOZAL * * *
THIS IS NOT A NEW REPORT.
This event report was originally withheld from public release under the NRC's policy for protecting sensitive unclassified information. The NRC has reevaluated this policy and is now making this event report available to the public with suitable redactions.
***********************************************************************************************************************************
***********************************************************************************************************************************
THIS IS NOT A NEW REPORT.
This event report was originally withheld from public release under the NRC's policy for protecting sensitive unclassified information. The NRC has reevaluated this policy and is now making this event report available to the public with suitable redactions.
***********************************************************************************************************************************
Tornado Warnings were issued for Campbell County, Virginia and an Alert was declared at 1434 EDT. The facility activated its Emergency Operations Center, secured operations and materials, and subsequently sheltered employees. The NRC was not placed in a Response Mode.
Additional notifications: EPA/NRC (Melby), HHS (Roger)
* * * UPDATE AT 1521 EDT ON 09/17/04 FROM MYRTLE AKRES TO MIKE RIPLEY * * *
The Tornado Warnings were cancelled, and the Alert was terminated.
Notified RDO (Boland), NMSS EO (Essig), IRD Manager (Wilson), OC (Outlaw), PAO (Hayden), DHS, FEMA, DOE, EPA/NRC, USDA, and HHS.
* * * UPDATE ON 05/13/08 BY J.KOZAL * * *
THIS IS NOT A NEW REPORT.
This event report was originally withheld from public release under the NRC's policy for protecting sensitive unclassified information. The NRC has reevaluated this policy and is now making this event report available to the public with suitable redactions.
***********************************************************************************************************************************