Event Notification Report for September 09, 2004
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
09/08/2004 - 09/09/2004
EVENT NUMBERS
41033410284102941030
General Information or Other
Event Number: 41033
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: GEOTEST ENGINEERING, INC.
Region: 4
City: HOUSTON State: TX
County:
License #: L02735-011
Agreement: Y
Docket:
NRC Notified By: JAMES H. OGDEN, JR.
HQ OPS Officer: HOWIE CROUCH
Licensee: GEOTEST ENGINEERING, INC.
Region: 4
City: HOUSTON State: TX
County:
License #: L02735-011
Agreement: Y
Docket:
NRC Notified By: JAMES H. OGDEN, JR.
HQ OPS Officer: HOWIE CROUCH
Notification Date: 09/09/2004
Notification Time: 16:10 [ET]
Event Date: 09/09/2004
Event Time: 08:45 [CDT]
Last Update Date: 09/09/2004
Notification Time: 16:10 [ET]
Event Date: 09/09/2004
Event Time: 08:45 [CDT]
Last Update Date: 09/09/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
GREG PICK (R4)
SCOTT MOORE (NMSS)
GREG PICK (R4)
SCOTT MOORE (NMSS)
TEXAS AGREEMENT STATE REPORT - DAMAGED TROXLER MOISTURE DENSITY GAUGE
The following information was received from Texas Department of State Health Services:
"At approximately 8:45 a.m. the gauge operator had just completed a density test on the site of Wheatley High School, where a new high school is being constructed, when a bulldozer, belonging to another contractor working at the job site, made a sudden and unexpected move toward the operator, who was performing calculations beside the gauge. During the movement the bulldozer operator dropped the blade of the vehicle which impacted the Troxler Model 3430, Serial No. 25129 moisture density gauge. The gauge was crushed with damage to the housing. The gauge contained two sealed sources: Cs-137, nominal 8 millicuries, Serial No. 75-7305 and Am-241/Be, nominal 40 millicuries, Serial No. 47-21337. The sources were not damaged nor leaking. The gauge control rod was in the up and locked. A survey of the area determined that no leakage where the gauge was crushed or to the blade of the bulldozer. The gauge was transported to Component Sales and Services (L02243-000) for leak testing and determination of possible repair. The gauge was determined to be not repairable. The gauge was transferred to Component Sales and Services for disposal. The gauge was last leak tested on April 4, 2004, with negative test results."
Texas Incident No. I-8161.
The following information was received from Texas Department of State Health Services:
"At approximately 8:45 a.m. the gauge operator had just completed a density test on the site of Wheatley High School, where a new high school is being constructed, when a bulldozer, belonging to another contractor working at the job site, made a sudden and unexpected move toward the operator, who was performing calculations beside the gauge. During the movement the bulldozer operator dropped the blade of the vehicle which impacted the Troxler Model 3430, Serial No. 25129 moisture density gauge. The gauge was crushed with damage to the housing. The gauge contained two sealed sources: Cs-137, nominal 8 millicuries, Serial No. 75-7305 and Am-241/Be, nominal 40 millicuries, Serial No. 47-21337. The sources were not damaged nor leaking. The gauge control rod was in the up and locked. A survey of the area determined that no leakage where the gauge was crushed or to the blade of the bulldozer. The gauge was transported to Component Sales and Services (L02243-000) for leak testing and determination of possible repair. The gauge was determined to be not repairable. The gauge was transferred to Component Sales and Services for disposal. The gauge was last leak tested on April 4, 2004, with negative test results."
Texas Incident No. I-8161.
Power Reactor
Event Number: 41028
Facility: SALEM
Region: 1 State: NJ
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: M. STRAUBMULLER
HQ OPS Officer: JOHN MacKINNON
Region: 1 State: NJ
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: M. STRAUBMULLER
HQ OPS Officer: JOHN MacKINNON
Notification Date: 09/09/2004
Notification Time: 03:20 [ET]
Event Date: 09/09/2004
Event Time: 01:06 [EDT]
Last Update Date: 09/09/2004
Notification Time: 03:20 [ET]
Event Date: 09/09/2004
Event Time: 01:06 [EDT]
Last Update Date: 09/09/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL
Person (Organization):
HAROLD GRAY (R1)
HAROLD GRAY (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | A/R | Y | 100 | Power Operation | 0 | Hot Standby |
TURBINE TRIP/REACTOR TRIP
"Salem Unit 2 experienced a Turbine Trip > P-9 which initiated a Reactor Trip. All rods fully inserted. Aux Feedwater auto start initiated on steam generator low-low level. The cause of the turbine trip is Generator Diff [Differential Current] or Loss of Field. Decay heat removal is via the steam dumps to the main condenser. All safety related systems are available and functioned as designed. The 500 KV breaker 2-10 was cleared and tagged prior to the trip. Upon the turbine/reactor trip, the 500KV breakers 1-9 and 9-10 opened as designed. Due to the 2-10, 1-9, 9-10 breakers being opened, the 500 KV transmission line 5037 is de-energized. Two offsite power sources are available and all 3 Emergency Diesel Generators are operable. The 5037 line will be energized following restoration from scheduled maintenance. There were no personnel injuries."
The licensee stated that the NRC resident inspector and the local township were notified.
"Salem Unit 2 experienced a Turbine Trip > P-9 which initiated a Reactor Trip. All rods fully inserted. Aux Feedwater auto start initiated on steam generator low-low level. The cause of the turbine trip is Generator Diff [Differential Current] or Loss of Field. Decay heat removal is via the steam dumps to the main condenser. All safety related systems are available and functioned as designed. The 500 KV breaker 2-10 was cleared and tagged prior to the trip. Upon the turbine/reactor trip, the 500KV breakers 1-9 and 9-10 opened as designed. Due to the 2-10, 1-9, 9-10 breakers being opened, the 500 KV transmission line 5037 is de-energized. Two offsite power sources are available and all 3 Emergency Diesel Generators are operable. The 5037 line will be energized following restoration from scheduled maintenance. There were no personnel injuries."
The licensee stated that the NRC resident inspector and the local township were notified.
Power Reactor
Event Number: 41029
Facility: SUSQUEHANNA
Region: 1 State: PA
Unit: [1] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: RON ROLAND
HQ OPS Officer: JOHN MacKINNON
Region: 1 State: PA
Unit: [1] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: RON ROLAND
HQ OPS Officer: JOHN MacKINNON
Notification Date: 09/09/2004
Notification Time: 09:31 [ET]
Event Date: 09/09/2004
Event Time: 04:24 [EDT]
Last Update Date: 09/09/2004
Notification Time: 09:31 [ET]
Event Date: 09/09/2004
Event Time: 04:24 [EDT]
Last Update Date: 09/09/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
HAROLD GRAY (R1)
HAROLD GRAY (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
LOSS OF EMERGENCY ASSESSMENT CAPABILITY
At 04:24 EDT, the Control Room Super Particulate Iodine Noble Gas (SPING), Stack Monitoring System, terminal and the associated terminal in the Technical Support Center (TSC) began printing transmit and receive errors. As a result, all SPINGs were declared inoperable and associated Technical Requirements actions entered for alternate sampling. Review by Nuclear Regulatory Affairs and Shift Supervisor considers the occurrence a loss of Emergency Assessment Capability and is therefore reportable under 10 CFR 50.72(b)(3)(xiii).
Licensee is taking samples every 4 hours.
The NRC Resident Inspector was notified of this event by the licensee.
At 04:24 EDT, the Control Room Super Particulate Iodine Noble Gas (SPING), Stack Monitoring System, terminal and the associated terminal in the Technical Support Center (TSC) began printing transmit and receive errors. As a result, all SPINGs were declared inoperable and associated Technical Requirements actions entered for alternate sampling. Review by Nuclear Regulatory Affairs and Shift Supervisor considers the occurrence a loss of Emergency Assessment Capability and is therefore reportable under 10 CFR 50.72(b)(3)(xiii).
Licensee is taking samples every 4 hours.
The NRC Resident Inspector was notified of this event by the licensee.
Transportation Event
Event Number: 41030
Rep Org: MISSOURI DEPT. OF TRANSPORTATION
Licensee: MISSOURI DEPT OF TRANSPORTATION
Region: 3
City: LEETON State: MO
County: JOHNSON
License #:
Agreement: N
Docket:
NRC Notified By: GARY BUTTERWORTH
HQ OPS Officer: JOHN MacKINNON
Licensee: MISSOURI DEPT OF TRANSPORTATION
Region: 3
City: LEETON State: MO
County: JOHNSON
License #:
Agreement: N
Docket:
NRC Notified By: GARY BUTTERWORTH
HQ OPS Officer: JOHN MacKINNON
Notification Date: 09/09/2004
Notification Time: 10:24 [ET]
Event Date: 09/09/2004
Event Time: 07:45 [CDT]
Last Update Date: 09/09/2004
Notification Time: 10:24 [ET]
Event Date: 09/09/2004
Event Time: 07:45 [CDT]
Last Update Date: 09/09/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
DAVID HILLS (R3)
MICHELE BURGESS (NMSS)
PLUMMER (DOT)
JOE STAMBAUGH (DOE)
JANNIE EVERETTE (DOE)
DAVID HILLS (R3)
MICHELE BURGESS (NMSS)
PLUMMER (DOT)
JOE STAMBAUGH (DOE)
JANNIE EVERETTE (DOE)
MISSOURI DEPT. OF TRANSPORTATION PICKUP TRUCK CARRYING A TROXLER GAUGE WAS INVOLVED IN AN ACCIDENT.
At 0745 CDT a Missouri Department of transportation pickup truck carrying a Troxler model # 3430 moisture density gauge was involved in an accident. The Troxler gauge was within it case locked inside a metal locked box bolted to the bed of the pickup truck. The open bed pickup truck was traveling on Route E, located between Leeton and 23rd highway in Johnson county, when it was side swiped by another vehicle. The pickup truck slid down the side of a hill. The front quarter panel of the truck was damaged and the truck's side mirror was knocked off. The occupants of the pickup truck got out of the truck and went to the back of the truck, opened the locked metal box and observed that the Troxler moisture density gauge was still in its container undamaged. The Troxler gauge contains 0.3 Gigabecquerels (GBq) of cesium-137 and 1.48 Gigabecquerels (GBq) of americium-241/Be. Nobody was injured in the accident.
At 0745 CDT a Missouri Department of transportation pickup truck carrying a Troxler model # 3430 moisture density gauge was involved in an accident. The Troxler gauge was within it case locked inside a metal locked box bolted to the bed of the pickup truck. The open bed pickup truck was traveling on Route E, located between Leeton and 23rd highway in Johnson county, when it was side swiped by another vehicle. The pickup truck slid down the side of a hill. The front quarter panel of the truck was damaged and the truck's side mirror was knocked off. The occupants of the pickup truck got out of the truck and went to the back of the truck, opened the locked metal box and observed that the Troxler moisture density gauge was still in its container undamaged. The Troxler gauge contains 0.3 Gigabecquerels (GBq) of cesium-137 and 1.48 Gigabecquerels (GBq) of americium-241/Be. Nobody was injured in the accident.