Event Notification Report for August 30, 2004
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
08/29/2004 - 08/30/2004
General Information or Other
Event Number: 41222
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: Schlumberger Technology Corporation
Region: 4
City: Sugar Land State: TX
County: San Jacinto
License #: L01833
Agreement: Y
Docket:
NRC Notified By: JIM OGDEN
HQ OPS Officer: HOWIE CROUCH
Licensee: Schlumberger Technology Corporation
Region: 4
City: Sugar Land State: TX
County: San Jacinto
License #: L01833
Agreement: Y
Docket:
NRC Notified By: JIM OGDEN
HQ OPS Officer: HOWIE CROUCH
Notification Date: 11/24/2004
Notification Time: 09:34 [ET]
Event Date: 08/30/2004
Event Time: 00:00 [CST]
Last Update Date: 11/24/2004
Notification Time: 09:34 [ET]
Event Date: 08/30/2004
Event Time: 00:00 [CST]
Last Update Date: 11/24/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
JEFFERY CLARK (R4)
JOHN HICKEY (NMSS)
JEFFERY CLARK (R4)
JOHN HICKEY (NMSS)
TEXAS AGREEMENT STATE REPORT - ABANDONED WELL LOGGING SOURCE
"On August 30, 2004, Schlumberger Technology Corporation was logging the Allar #1 well, operated by Famcor Oil, Inc., API # 42-407-30612, located in San Jacinto County, Texas. The well logging tool string became stuck during logging operations in the 11,998 foot well. The source string is below 3,319 feet of drill pipe stuck in sand-shale and sand-shale interfaces. Multiple attempts at recovery were conducted between 10/22/2004 and 10/29/2004. The Licensee notified the Agency of probable abandonment on 10/28/2004. The tool string contained two sealed radioactive well logging sources. The Licensee has not informed the Agency of the manufacturer of the sources. However, the 16 Curie Am-241/Be Neutron source, Model NSRF, Serial No G5053, is stuck and cemented in place at 8,326 feet [mine depth (MD)] , and the 1.7 Curie Cs-137 Density source, Model GSRJ, Serial No. Al 927, is stuck and cemented in place at 8,339 feet MD. Both sources were last leak tested on April 3, 2004, and were current on the date the sources became stuck in the well bore. Two-hundred feet of red oxide dyed cement is spotted on top of the stuck drill pipe from 4,984 feet to 4,750 feet. A used drill bit was placed as a deflection device at 4,750 feet. An additional 208 feet of cement was place on top of the drill bit, with the top of the cement located at 4,550 feet. The job was completed on October 30, 2004. A required plaque was ordered on November 19, 2004, and will be placed on the well head when received."
Texas Incident No. I-8185
"On August 30, 2004, Schlumberger Technology Corporation was logging the Allar #1 well, operated by Famcor Oil, Inc., API # 42-407-30612, located in San Jacinto County, Texas. The well logging tool string became stuck during logging operations in the 11,998 foot well. The source string is below 3,319 feet of drill pipe stuck in sand-shale and sand-shale interfaces. Multiple attempts at recovery were conducted between 10/22/2004 and 10/29/2004. The Licensee notified the Agency of probable abandonment on 10/28/2004. The tool string contained two sealed radioactive well logging sources. The Licensee has not informed the Agency of the manufacturer of the sources. However, the 16 Curie Am-241/Be Neutron source, Model NSRF, Serial No G5053, is stuck and cemented in place at 8,326 feet [mine depth (MD)] , and the 1.7 Curie Cs-137 Density source, Model GSRJ, Serial No. Al 927, is stuck and cemented in place at 8,339 feet MD. Both sources were last leak tested on April 3, 2004, and were current on the date the sources became stuck in the well bore. Two-hundred feet of red oxide dyed cement is spotted on top of the stuck drill pipe from 4,984 feet to 4,750 feet. A used drill bit was placed as a deflection device at 4,750 feet. An additional 208 feet of cement was place on top of the drill bit, with the top of the cement located at 4,550 feet. The job was completed on October 30, 2004. A required plaque was ordered on November 19, 2004, and will be placed on the well head when received."
Texas Incident No. I-8185
Other Nuclear Material
Event Number: 40997
Rep Org: ATLANTIC GEOTECHNICAL SERVICES
Licensee: ATLANTIC GEOTECHNICAL SERVICES
Region: 1
City: ASHLAND State: VA
County:
License #: 45-25191-01
Agreement: N
Docket:
NRC Notified By: EDITH POPP
HQ OPS Officer: ARLON COSTA
Licensee: ATLANTIC GEOTECHNICAL SERVICES
Region: 1
City: ASHLAND State: VA
County:
License #: 45-25191-01
Agreement: N
Docket:
NRC Notified By: EDITH POPP
HQ OPS Officer: ARLON COSTA
Notification Date: 08/30/2004
Notification Time: 07:35 [ET]
Event Date: 08/30/2004
Event Time: 00:00 [EDT]
Last Update Date: 09/17/2004
Notification Time: 07:35 [ET]
Event Date: 08/30/2004
Event Time: 00:00 [EDT]
Last Update Date: 09/17/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
EUGENE COBEY (R1)
JOHN HICKEY (NMSS)
JIM WHITNEY (TAS)
EUGENE COBEY (R1)
JOHN HICKEY (NMSS)
JIM WHITNEY (TAS)
STOLEN TROXLER GAUGE
Licensee technician reported to Richland, VA police that his vehicle (SUV) was stolen from his home possibly early this morning and that a Troxler gauge model 3430 (S/N 30179) was stored in the vehicle. The gauge was double locked in its casing and contains a Cesium 137 source (S/N 750-1869, current activity 7.4 millicuries) and a Americium 241:Beryllium source (S/N 47-271-56, current activity 39.7 millicuries). The licensee is contacting the Richland police once again to raise their awareness that this gauge contains radioactive materials.
* * * UPDATE 1000 EDT ON 9/17/04 FROM EDITH POPP TO S. SANDIN * * *
The stolen Troxler gauge was recovered intact late in the evening of 9/16/04 and returned to the custody of the licensee. The licensee verified that there were no leaks. Notified R1DO (Doerflein) and NMSS (Miller).
Licensee technician reported to Richland, VA police that his vehicle (SUV) was stolen from his home possibly early this morning and that a Troxler gauge model 3430 (S/N 30179) was stored in the vehicle. The gauge was double locked in its casing and contains a Cesium 137 source (S/N 750-1869, current activity 7.4 millicuries) and a Americium 241:Beryllium source (S/N 47-271-56, current activity 39.7 millicuries). The licensee is contacting the Richland police once again to raise their awareness that this gauge contains radioactive materials.
* * * UPDATE 1000 EDT ON 9/17/04 FROM EDITH POPP TO S. SANDIN * * *
The stolen Troxler gauge was recovered intact late in the evening of 9/16/04 and returned to the custody of the licensee. The licensee verified that there were no leaks. Notified R1DO (Doerflein) and NMSS (Miller).
Power Reactor
Event Number: 40998
Facility: NINE MILE POINT
Region: 1 State: NY
Unit: [1] [] []
RX Type: [1] GE-2,[2] GE-5
NRC Notified By: DON SHEEHAN
HQ OPS Officer: STEVE SANDIN
Region: 1 State: NY
Unit: [1] [] []
RX Type: [1] GE-2,[2] GE-5
NRC Notified By: DON SHEEHAN
HQ OPS Officer: STEVE SANDIN
Notification Date: 08/30/2004
Notification Time: 11:42 [ET]
Event Date: 08/30/2004
Event Time: 08:35 [EDT]
Last Update Date: 08/31/2004
Notification Time: 11:42 [ET]
Event Date: 08/30/2004
Event Time: 08:35 [EDT]
Last Update Date: 08/31/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
PAMELA HENDERSON (R1)
PAMELA HENDERSON (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | M/R | Y | 100 | Power Operation | 0 | Hot Shutdown |
UNIT 1 MANUALLY SCRAMMED DUE TO OSCILLATING REACTOR VESSEL WATER LEVEL
"Nine Mile Point, Unit One is initiating a 10 CFR 50.72 (b) (2) (iv) (B) 4-Hour Non-Emergency notification based upon insertion of a 'MANUAL' scram that occurred at 08:35 on Monday, August 30, 2004.
"At time of transient, plant was operating in Mode 1, Power Operating Condition, at 99.7% of rated power.
"At 08:25 on Monday, August 30, 2004, Operators noted oscillations on 13 Feedwater flow control valve (FCV) while in 'AUTOMATIC' mode of operation (normal mode of operation for this equipment). Operators took "MANUAL" control of 13 FCV per Plant Operating Procedures. 13 FCV oscillations continued while in the 'MANUAL' mode, and a decision was made to insert a 'MANUAL' scram at 08:35. All control rods fully inserted and the plant responded as designed to the scram.
"At 08:44, the scram signal was reset per procedure.
"Currently, plant is in Mode 2, Hot Shutdown Condition with cooldown in progress. Plant is transitioning to Mode 3, Cold Shutdown Condition, per Plant Operating Procedures."
At the time the manual scram was inserted, Reactor Vessel Water Level (RVWL) was 67 inches and decreasing (automatic scram setpoint is 53 inches). The 13 FCV is on the discharge of the turbine-driven feedwater pump. Decay heat is currently being removed by the main condenser via the steam bypass valves. All ECCS and safety-related equipment is available, if needed. At the time of the transient there was no plant maintenance on-going which could have been a contributing factor.
The licensee informed the NRC Resident Inspector.
* * * UPDATE ON 8/30/04 AT 2358 EDT FROM M. MINNICK TO J. ROTTON * * *
"The notification sent to the NRC on 8/30/04 at 11:42 was found to be incomplete. As a normal and expected response to a manual scram at high power, the High Pressure Coolant Injection System (feedwater) automatically initiated during the transient following the manual scram. This should have been reported as an 8 hour Non-Emergency 10CFR50. 72 (b) (3) (iv) (A) notification."
The licensee notified the NRC Resident Inspector.
Notified R1DO (Henderson).
"Nine Mile Point, Unit One is initiating a 10 CFR 50.72 (b) (2) (iv) (B) 4-Hour Non-Emergency notification based upon insertion of a 'MANUAL' scram that occurred at 08:35 on Monday, August 30, 2004.
"At time of transient, plant was operating in Mode 1, Power Operating Condition, at 99.7% of rated power.
"At 08:25 on Monday, August 30, 2004, Operators noted oscillations on 13 Feedwater flow control valve (FCV) while in 'AUTOMATIC' mode of operation (normal mode of operation for this equipment). Operators took "MANUAL" control of 13 FCV per Plant Operating Procedures. 13 FCV oscillations continued while in the 'MANUAL' mode, and a decision was made to insert a 'MANUAL' scram at 08:35. All control rods fully inserted and the plant responded as designed to the scram.
"At 08:44, the scram signal was reset per procedure.
"Currently, plant is in Mode 2, Hot Shutdown Condition with cooldown in progress. Plant is transitioning to Mode 3, Cold Shutdown Condition, per Plant Operating Procedures."
At the time the manual scram was inserted, Reactor Vessel Water Level (RVWL) was 67 inches and decreasing (automatic scram setpoint is 53 inches). The 13 FCV is on the discharge of the turbine-driven feedwater pump. Decay heat is currently being removed by the main condenser via the steam bypass valves. All ECCS and safety-related equipment is available, if needed. At the time of the transient there was no plant maintenance on-going which could have been a contributing factor.
The licensee informed the NRC Resident Inspector.
* * * UPDATE ON 8/30/04 AT 2358 EDT FROM M. MINNICK TO J. ROTTON * * *
"The notification sent to the NRC on 8/30/04 at 11:42 was found to be incomplete. As a normal and expected response to a manual scram at high power, the High Pressure Coolant Injection System (feedwater) automatically initiated during the transient following the manual scram. This should have been reported as an 8 hour Non-Emergency 10CFR50. 72 (b) (3) (iv) (A) notification."
The licensee notified the NRC Resident Inspector.
Notified R1DO (Henderson).