Skip to main content

Event Notification Report for August 20, 2004

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
08/19/2004 - 08/20/2004

EVENT NUMBERS
409864097540970

General Information or Other
Event Number: 40986
Rep Org: MA RADIATION CONTROL PROGRAM
Licensee: AEA TECHNOLOGY QSA INC
Region: 1
City: BURLINGTON   State: MA
County:
License #: 12-8361
Agreement: Y
Docket:
NRC Notified By: JOSH DAEHLER
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 08/26/2004
Notification Time: 11:21 [ET]
Event Date: 08/20/2004
Event Time: 16:00 [EDT]
Last Update Date: 08/26/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
EUGENE COBEY (R1)
ERIC DUNCAN (R3)
TOM ESSIG (NMSS)
Event Text
AEA TECHNOLOGY REPORTED RECEIVING A LEAKING SOURCE FROM ONE OF THEIR CUSTOMERS

AEA reports that an AEA Model PDM.1002.Hn Series static eliminator device, containing approximately 3 millicuries of polonium-210 was returned from a customer and found to be leaking. A wipe survey of the NRD, Inc. Model P-001 foil sealed source contained in the device measured 0.008 microcuries of polonium-210. Wipe survey of the outside package detected no contamination. The device was received from AEA's customer, Hank Graff Chevrolet in Davidson, MI. on August 19, 2004. AEA contacted the sealed source manufacturer, NRD, Inc.

AEA Technology QSA, Inc. (AEA) sealed the source in a plastic bag and the immediate area was checked for further contamination. No contamination other than what was on the source was found. AEA contacted the source manufacturer, NRD, Inc. An investigation is pending. The Agency will notify the U.S. NRC and the State of New York as applicable to the device customer site and source manufacturer site jurisdiction.


Other Nuclear Material
Event Number: 40975
Rep Org: DOMINION GEOTECHNICAL
Licensee: DOMINION GEOTHECNICAL
Region: 1
City: GARRISONVILLE   State: VA
County: STAFFORD
License #: 45-30860-01
Agreement: N
Docket:
NRC Notified By: KEVIN PARRIS
HQ OPS Officer: HOWIE CROUCH
Notification Date: 08/23/2004
Notification Time: 09:34 [ET]
Event Date: 08/20/2004
Event Time: 11:00 [EDT]
Last Update Date: 08/23/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JOHN WHITE (R1)
LINDA PSYK-GERSEY (NMSS)
Event Text
DAMAGED TROXLER MOISTURE DENSITY GAUGE

The licensee reported that a Troxler Moisture Density Gauge, Model 3411, Serial Number 13101, was damaged when it was run over by a soil compacting roller. The gauge suffered a cracked housing and a bent handle but the source is retracted into the shield. The gauge contains 8 milliCuries of Cs-137 and 40 milliCuries of Am:Be. Leak test results are pending. Radiation readings taken 1 meter away from the gauge indicated 50 microRem/hr and reading taken on contact were 1.5 milliRem/hr.

The gauge is currently stored at the licensee's facility awaiting transfer to the vendor for repair or disposal.


Power Reactor
Event Number: 40970
Facility: SUSQUEHANNA
Region: 1     State: PA
Unit: [1] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: RONALD FRY
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 08/20/2004
Notification Time: 17:48 [ET]
Event Date: 08/20/2004
Event Time: 12:15 [EDT]
Last Update Date: 08/20/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(C) - POT UNCNTRL RAD REL
Person (Organization):
JOHN WHITE (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
RAILROAD ACCESS PROCESS RADIATION MONITORS ACTUATION CAPABILITY WAS INADVERTENTLY DEFEATED

At 12:15 PM on 8/20/04, it was discovered that actions performed on 7/16/04 in support of Dry Fuel Storage activities to defeat the Railroad Access Area Radiation Monitor alarm horn had also defeated the actuation capability of the Railroad Access Process Radiation monitors. Per Technical Specifications, the process monitors are required to be operable "during movement of irradiated fuel assemblies within the Railroad Access Shaft, and above the Railroad Access Shaft with the Railroad Access Shaft Equipment Hatch open." Contrary to the Tech Spec requirement, two loaded Dry Fuel Storage Casks were lowered in the Railroad Shaft, one on 8/2/04 and the second on 8/16/04, with the radiation monitors inoperable. During this period the automatic isolation and re-alignment of Reactor Building Zone lll, automatic start of Reactor Building Recirculation Fans, and the automatic starts of SGTS and CREOASS would not have actuated from a HI-HI Radiation condition in the Railroad Access Shaft. Actual radiological conditions observed during the transfer of the casks in the railroad shaft would not have resulted in the need for system actuation. All other instruments in the Reactor Building ventilation system which actuate these systems were operable as required by Tech Specs. The jumpers which defeated the actuation capability were removed on 8/20/04 at 1400 [hrs.].

This event is considered reportable under 50.72(b)(3)(v)(C) as a loss of safety function.

The NRC Resident Inspector was notified.