Skip to main content

Event Notification Report for July 15, 2004

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
07/14/2004 - 07/15/2004

EVENT NUMBERS
408834087540892

General Information or Other
Event Number: 40883
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: APEX GEOSCIENCE, INC.
Region: 4
City: PLANO   State: TX
County:
License #: L04929-004
Agreement: Y
Docket:
NRC Notified By: JAMES H. OGDEN
HQ OPS Officer: STEVE SANDIN
Notification Date: 07/20/2004
Notification Time: 13:13 [ET]
Event Date: 07/15/2004
Event Time: 07:30 [CDT]
Last Update Date: 07/20/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
TOM FARNHOLTZ (R4)
THOMAS ESSIG (NMSS)
CNSNS (MEXICO) (FAX)
Event Text
AGREEMENT STATE REPORT INVOLVING A STOLEN TROXLER GAUGE

"Moisture density gauge believed to be stolen during a stop at Lowes, Plano, Texas, to pickup parts. The operator claims that the chain or lock was cut. The chain and lock were not left behind. The gauge is a Troxler Model 3440, Serial No. 33851 with two sealed sources: Cs-137, 8 millicuries, Serial No. 750-9505 and Am-241/Be, 40 millicuries, Serial No. 47-3391. Both sources were last leak tested June 1, 2004. Driver left Lowes and proceeded to a convenience store across the parking lot for a carton of cigarettes. Upon returning to the truck the gauge was noted as missing. The vehicle was a company truck: white, Ford Ranger, #51, with green logos on both sides.

"Media attention: None known. Licensee is contemplating offering a reward for return of the gauge."

The Plano Police Department was notified of this incident. Texas Incident No.: I-8144.


Power Reactor
Event Number: 40875
Facility: SALEM
Region: 1     State: NJ
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: PAUL ABBOTT
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 07/15/2004
Notification Time: 22:18 [ET]
Event Date: 07/15/2004
Event Time: 19:44 [EDT]
Last Update Date: 07/15/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
GLENN MEYER (R1)
JOHN HANNON (NRR)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 M/R Y 8 Power Operation 0 Hot Standby
Event Text
MANUAL TRIP FROM 8% POWER DUE TO LOWERING WATER LEVEL ON 23 STEAM GENERATOR

During plant start up, a manual Reactor trip was initiated in response to lowering water level on 23 Steam Generator. All systems responded as required. All control rods fully inserted and no ECCS actuated or relief valves lifted. Both motor driven auxiliary feedwater pumps (21 and 22) started as expected on the low level signals from 23 Steam Generator. The steam driven auxiliary feed (23) pump was not required to start and remained in standby. Decay heat is being removed via the main steam dump system to the main condenser. The reactor is currently at normal operating temperature and pressure. No major equipment was unavailable at the time of the trip. No personnel injuries occurred as a result of this event. The cause of the low steam generator level is being investigated.


The NRC Resident Inspector was notified along with Lower Alloway Creek Township. The States of New Jersey and Delaware will be notified.


Hospital
Event Number: 40892
Rep Org: DANVILLE REGIONAL MEDICAL CENTER
Licensee: DANVILLE REGIONAL MEDICAL CENTER
Region: 1
City: DANVILLE   State: VA
County:
License #: 45-151544-03
Agreement: N
Docket:
NRC Notified By: GEORGE SHEROUSE
HQ OPS Officer: ARLON COSTA
Notification Date: 07/22/2004
Notification Time: 13:30 [ET]
Event Date: 07/15/2004
Event Time: 14:00 [EDT]
Last Update Date: 07/22/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
35.3045(a)(1) - DOSE <> PRESCRIBED DOSAGE
Person (Organization):
JOHN KINNEMAN (R1)
JOHN HICKEY (NMSS)
Event Text
LESS THAN PRESCRIBED DOSAGE TO ORGAN

A patient was prescribed placement of 74 seeds of Iodine 125 to the prostate. Only 38% of the volume of the prostate received the prescribed dose of 160 grays. The radiation oncologist used poor technique in placing the iodine seeds in the prostate. There were no other safety issues related to this incident. The patient has been contacted and will come in for consultation. The licensee will review this incident and will follow up with a written report, if required.