Event Notification Report for July 06, 2004
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
07/05/2004 - 07/06/2004
Power Reactor
Event Number: 40853
Facility: CATAWBA
Region: 2 State: SC
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: RICHARD BENNETT
HQ OPS Officer: JOHN MacKINNON
Region: 2 State: SC
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: RICHARD BENNETT
HQ OPS Officer: JOHN MacKINNON
Notification Date: 07/06/2004
Notification Time: 17:16 [ET]
Event Date: 07/06/2004
Event Time: 10:08 [EDT]
Last Update Date: 07/06/2004
Notification Time: 17:16 [ET]
Event Date: 07/06/2004
Event Time: 10:08 [EDT]
Last Update Date: 07/06/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
KERRY LANDIS (R2)
KERRY LANDIS (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
GREATER THAN 25% OF THE EMERGENCY SIRENS FOUND TO BE INOPERABLE
26 of 89 of Catawba's sirens failed a low growl activation test at 1008 EDT 07/06/04. Upon activation of the quarterly full cycle test at 1152 EDT 07/06/04, only 3 of the 26 failed to operate properly. Greater than 25% of the sirens were inoperable for more than one hour (one hour and 44 minutes). Investigation is in progress as to determine why the low growl test was unsuccessful.
The licensee notified the States of South Carolina and North Carolina of this event.
The NRC Resident Inspector will be notified of this event by the licensee.
26 of 89 of Catawba's sirens failed a low growl activation test at 1008 EDT 07/06/04. Upon activation of the quarterly full cycle test at 1152 EDT 07/06/04, only 3 of the 26 failed to operate properly. Greater than 25% of the sirens were inoperable for more than one hour (one hour and 44 minutes). Investigation is in progress as to determine why the low growl test was unsuccessful.
The licensee notified the States of South Carolina and North Carolina of this event.
The NRC Resident Inspector will be notified of this event by the licensee.
General Information or Other
Event Number: 40864
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: COMPUTALOG WIRELINE SERVICE, INC.
Region: 4
City: BRYAN MOUND STRATEGIC PET RES State: TX
County: BRAZORIA
License #: L04286-018
Agreement: Y
Docket:
NRC Notified By: JAMES H. OGDEN, JR.
HQ OPS Officer: STEVE SANDIN
Licensee: COMPUTALOG WIRELINE SERVICE, INC.
Region: 4
City: BRYAN MOUND STRATEGIC PET RES State: TX
County: BRAZORIA
License #: L04286-018
Agreement: Y
Docket:
NRC Notified By: JAMES H. OGDEN, JR.
HQ OPS Officer: STEVE SANDIN
Notification Date: 07/12/2004
Notification Time: 14:38 [ET]
Event Date: 07/06/2004
Event Time: 00:00 [CDT]
Last Update Date: 07/12/2004
Notification Time: 14:38 [ET]
Event Date: 07/06/2004
Event Time: 00:00 [CDT]
Last Update Date: 07/12/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
DALE POWERS (R4)
SCOTT MOORE (NMSS)
DALE POWERS (R4)
SCOTT MOORE (NMSS)
AGREEMENT STATE REPORT INVOLVING LOST WELL LOGGING SOURCE
"After performing services to determine the oil/water contact interface and the gas/oil interface levels the wireline with the source was being retracted. The wireline was attached to 1 11/16" tool in the salt dome. During retraction, the source evidently got hung on entry to the hole to the surface. It is felt that the crew was inattentive or possibly did not use proper procedure. The 'stuck' source broke loose of the wireline at the established weak point of connection between the tool and the wireline. Retrieval of the source is deemed unrecoverable. This is the second incident of this type in the same field. The source is a Gulf Nuclear, Model CSV-F74, Cs-137, 100 millicurie source. The probable depth of this source is estimated at approximately 4,000 feet. Investigation on site continues. A written report will be submitted to this Agency [Texas Department of Health]."
Texas Incident No.: I-8142
Event Location: Bryan Mound Strategic Petroleum Reserve, Brazoria County, Texas, Well # BM 104B
"After performing services to determine the oil/water contact interface and the gas/oil interface levels the wireline with the source was being retracted. The wireline was attached to 1 11/16" tool in the salt dome. During retraction, the source evidently got hung on entry to the hole to the surface. It is felt that the crew was inattentive or possibly did not use proper procedure. The 'stuck' source broke loose of the wireline at the established weak point of connection between the tool and the wireline. Retrieval of the source is deemed unrecoverable. This is the second incident of this type in the same field. The source is a Gulf Nuclear, Model CSV-F74, Cs-137, 100 millicurie source. The probable depth of this source is estimated at approximately 4,000 feet. Investigation on site continues. A written report will be submitted to this Agency [Texas Department of Health]."
Texas Incident No.: I-8142
Event Location: Bryan Mound Strategic Petroleum Reserve, Brazoria County, Texas, Well # BM 104B
General Information or Other
Event Number: 41522
Rep Org: ST. BARNABAS HEALTH CARE SYSTEM
Licensee: NUCLETRON, INC
Region: 1
City: LIVINGSTON State: NJ
County:
License #: 29-01608-03
Agreement: N
Docket:
NRC Notified By: DAVID STEIDLEY
HQ OPS Officer: JOHN KNOKE
Licensee: NUCLETRON, INC
Region: 1
City: LIVINGSTON State: NJ
County:
License #: 29-01608-03
Agreement: N
Docket:
NRC Notified By: DAVID STEIDLEY
HQ OPS Officer: JOHN KNOKE
Notification Date: 03/23/2005
Notification Time: 23:05 [ET]
Event Date: 07/06/2004
Event Time: 12:00 [EST]
Last Update Date: 03/24/2005
Notification Time: 23:05 [ET]
Event Date: 07/06/2004
Event Time: 12:00 [EST]
Last Update Date: 03/24/2005
Emergency Class: NON EMERGENCY
10 CFR Section:
21.21 - UNSPECIFIED PARAGRAPH
10 CFR Section:
21.21 - UNSPECIFIED PARAGRAPH
Person (Organization):
JOHN ROGGE (R1)
TOM ESSIG (NMSS)
M. BEARDSLEY (R1)
JOHN ROGGE (R1)
TOM ESSIG (NMSS)
M. BEARDSLEY (R1)
PART 21 REPORT ON BRACHYTHERAPY DEVICE (MICROSELETRON-HDR)
On July 6, 2004, while performing routine QC tests prior to patient treatment, the High Dose Rate afterloading brachytherapy device (microSeletron-HDR) failed to retract. With Nucletron service personnel on the phone giving technical support, the RSO entered the room and manually retracted the 6.7 Ci of Ir- 192 source. His whole body exposure was subsequently found to be 7 mRem and ring badge <10 mRem.
The device, which is manufactured by Nucletron, Inc, was found to have a defective "TU MPU PCB" board. After replacement and testing, the device was returned to operating status for future patient treatment.
On July 6, 2004, while performing routine QC tests prior to patient treatment, the High Dose Rate afterloading brachytherapy device (microSeletron-HDR) failed to retract. With Nucletron service personnel on the phone giving technical support, the RSO entered the room and manually retracted the 6.7 Ci of Ir- 192 source. His whole body exposure was subsequently found to be 7 mRem and ring badge <10 mRem.
The device, which is manufactured by Nucletron, Inc, was found to have a defective "TU MPU PCB" board. After replacement and testing, the device was returned to operating status for future patient treatment.