Power Reactor
Event Number: 40786
Facility: COOPER
Region: 4 State: NE
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: STEVEN JOBE
HQ OPS Officer: BILL GOTT
Region: 4 State: NE
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: STEVEN JOBE
HQ OPS Officer: BILL GOTT
Notification Date: 06/02/2004
Notification Time: 00:42 [ET]
Event Date: 06/01/2004
Event Time: 19:15 [CDT]
Last Update Date: 06/02/2004
Notification Time: 00:42 [ET]
Event Date: 06/01/2004
Event Time: 19:15 [CDT]
Last Update Date: 06/02/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
GARY SANBORN (R4)
GARY SANBORN (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
HPCI DECLARED INOPERABLE
"High Pressure Coolant Injection [HPCI] system was declared inoperable due to failure of alarm 'HPCI Turbine Exhaust Drain Pot Hi Level' to clear. The level switch associated with the alarm is the suspected failed component. When the line is drained there is evidence of water flow but the alarm does not clear. There are no other indications of the exhaust drain line filling with water.
"As a precautionary measure, the HPCI auxiliary oil pump has been placed in pull-to-lock, which will prevent the auto initiation of HPCI. HPCI will be manually started when required and proper operations assessed to ensure the exhaust line is intact. Hourly draining of the HPCI turbine exhaust drain line has been instituted based on the previously established frequency of the alarm.
"HPCI is considered available.
"All remaining ECCS systems are operable.
"The NRC Senior Resident Inspector has been notified of this event."
"High Pressure Coolant Injection [HPCI] system was declared inoperable due to failure of alarm 'HPCI Turbine Exhaust Drain Pot Hi Level' to clear. The level switch associated with the alarm is the suspected failed component. When the line is drained there is evidence of water flow but the alarm does not clear. There are no other indications of the exhaust drain line filling with water.
"As a precautionary measure, the HPCI auxiliary oil pump has been placed in pull-to-lock, which will prevent the auto initiation of HPCI. HPCI will be manually started when required and proper operations assessed to ensure the exhaust line is intact. Hourly draining of the HPCI turbine exhaust drain line has been instituted based on the previously established frequency of the alarm.
"HPCI is considered available.
"All remaining ECCS systems are operable.
"The NRC Senior Resident Inspector has been notified of this event."