Event Number: 40738
Facility: PADUCAH GASEOUS DIFFUSION PLANT
Region: 2     State: KY
Unit: [] [] []
RX Type: URANIUM ENRICHMENT FACILITY
Comments: 2 DEMOCRACY CENTER
6903 ROCKLEDGE DRIVE
BETHESDA, MD 20817 (301)564-3200
NRC Notified By: MATT MAURER
HQ OPS Officer: HOWIE CROUCH
Notification Date: 05/09/2004
Notification Time: 20:48 [ET]
Event Date: 05/09/2004
Event Time: 01:30 [CDT]
Last Update Date: 05/09/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
76.120(c)(2) - SAFETY EQUIPMENT FAILURE
Person (Organization):
KERRY LANDIS (R2)
Event Text
FAILURE OF THE HIGH VOLTAGE UF6 RELEASE DETECTION SYSTEM

The following information was obtained by the regulatee via facsimile:

"At 0130 [hrs. CDT] on 05-09-04, the Plant Shift Superintendent (PSS) was notified of a failure of the C-316 High Voltage UF6 Release Detection System. The High Voltage UF6 detection system was disabled by a computer malfunction. This High Voltage UF6 Release System is designed to activate alarms in the event of a UF6 release. The PSS declared the system inoperable and TSR [Technical Safety Requirement] LCO 2.3.4.4.A actions were implemented to post a continuous smoke watch in the affected area. The event is reportable as a 24 hour event, as required by 10 CFR 76.120(c)(2)(i); 'An event in which equipment is disabled or fails to function as designed when the equipment is required by a TSR to prevent releases, prevent exposures to radiation and radioactive materials exceeding specified limits, mitigate the consequences of an accident, or restore this facility to a preestablished safe condition after an accident.' The equipment was required by TSR to be available and operable and no redundant equipment was available to perform the required safety function.

"The Senior NRC Resident Inspector has been notified of this event."

The Automatic Data Processing (ADP) computer can be used to interface with the Process Gas Detection (PGD) system part of which is the High Voltage UF6 detection system. The PSS directed that the ADP be bypassed to isolate the fault from the system. The release detection system was tested satisfactorily and returned to service and the smoke watch was secured.


Power Reactor
Event Number: 40739
Facility: NORTH ANNA
Region: 2     State: VA
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: MARK A. SCHRY
HQ OPS Officer: JOHN MacKINNON
Notification Date: 05/10/2004
Notification Time: 00:11 [ET]
Event Date: 05/09/2004
Event Time: 20:05 [EDT]
Last Update Date: 05/10/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
KERRY LANDIS (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N N 0 Refueling 0 Refueling
Event Text
BOTH UNIT 2 EMERGENCY DIESELS DECLARED INOPERABLE DUE TO SHIMS/SUPPORTS FOUND TO BE EITHER MISSING OR NOT PROPERLY FASTENED.

"2-EE-EG-2H was out of service for scheduled maintenance. During an inspection, 4 shims on the exhaust stack seismic support on the south wall were found missing. The shims provide baseplate bearing on the concrete wall near each anchor bolt and had fallen to the floor. In addition, both lower anchor bolt nuts had worked loose and had fallen to the floor and one of the upper anchor bolt nuts had worked loose and was partially disengaged.

"Following this discovery 2-EE-EG-2J was inspected and 3 of the 4 supports were not properly fastened. 2J EDG was declared inoperable based on this discovery. Due to both U-2 Emergency Diesel Generators being in operable the safety functions needed to maintain the reactor in a safe shutdown condition and remove residual heat would have been imparted in the event of a loss of off site power

"2-EE-EG-2J was repaired and returned to operable at 2313 EST on May 09, 2004."

The NRC Resident Inspector was notified of this event by the licensee.