Event Notification Report for April 24, 2004

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
04/23/2004 - 04/24/2004

EVENT NUMBERS
407014070240703

Power Reactor
Event Number: 40701
Facility: OCONEE
Region: 2     State: SC
Unit: [] [2] []
RX Type: [1] B&W-L-LP,[2] B&W-L-LP,[3] B&W-L-LP
NRC Notified By: CHARLES HOLLAND
HQ OPS Officer: HOWIE CROUCH
Notification Date: 04/24/2004
Notification Time: 06:59 [ET]
Event Date: 04/24/2004
Event Time: 04:04 [EDT]
Last Update Date: 04/24/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xii) - OFFSITE MEDICAL
Person (Organization):
CAUDLE JULIAN (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Refueling 0 Refueling
Event Text
TRANSPORT OF POTENTIALLY CONTAMINATED INJURED PERSONNEL TO OFFSITE MEDICAL FACILITY

The following information was obtained from the licensee via facsimile:

"Individual transported to the hospital as potentially contaminated due to injury received in Unit 2 Reactor Containment Building. At 0430 on 4-24-04 EDT, individual left site by ambulance.

"RP [Radiation Protection] technician escorted injured person to hospital. RP has notified site that the injured person was not contaminated. (0500 EDT on 4-24-04)"

Injured person was transported to the Oconee Memorial Hospital using the hospital ambulance.

The licensee has notified the NRC Resident Inspector.


Power Reactor
Event Number: 40702
Facility: DRESDEN
Region: 3     State: IL
Unit: [] [2] []
RX Type: [1] GE-1,[2] GE-3,[3] GE-3
NRC Notified By: DENNIS FRANCIS
HQ OPS Officer: JEFF ROTTON
Notification Date: 04/24/2004
Notification Time: 09:00 [ET]
Event Date: 04/24/2004
Event Time: 06:03 [CDT]
Last Update Date: 04/24/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
DAVID HILLS (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 A/R Y 20 Power Operation 0 Hot Shutdown
Event Text
AUTOMATIC REACTOR SCRAM DUE TO MSIV CLOSURE

"This report is being made in accordance with 10 CFR 50.72 (b)(2)(iv)(B) .

"On 04/24/2004 at 06:03 [CDT], Dresden Unit 2 experienced an automatic Scram from 20% Reactor power
due to Main Steam Isolation Valve closure, cause is under investigation. There were no Electromatic Relief or Safety Relief Valve actuations and the Isolation Condenser was initiated manually for pressure control. There were no ECCS initiations. PCIS Group 2 and Group 3 Isolations occurred as expected due to normal reactor water level
decrease following the scram. All other systems responded as expected."

All control rods fully inserted on the automatic scram. The electric plant is in a normal lineup and being supplied from offsite power.

The licensee notified the NRC Resident Inspector.


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 40703
Facility: DRESDEN
Region: 3     State: IL
Unit: [] [2] []
RX Type: [1] GE-1,[2] GE-3,[3] GE-3
NRC Notified By: DENNIS FRANCIS
HQ OPS Officer: STEVE SANDIN
Notification Date: 04/24/2004
Notification Time: 15:30 [ET]
Event Date: 04/24/2004
Event Time: 10:50 [CDT]
Last Update Date: 06/23/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(B) - POT RHR INOP
Person (Organization):
DAVID HILLS (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Hot Shutdown 0 Hot Shutdown
Event Text
ISOLATION CONDENSER DECLARED INOPERABLE

"This report is being made in accordance with 10 CFR 50.72(b)(3)(v)(B).

"On 04/24/2004 at 06:03 [CDT], Dresden Unit 2 was using the Isolation Condenser to control reactor pressure following a Unit Scram. The isolation condenser operated properly until 10:50 [CDT] when the Isolation Condenser 2-1301-3 valve could not be opened to the full open position. ISO Condenser was declared INOPERABLE and Technical Specification Limiting Condition of Operation 3.5.3. Condition 'A' was ENTERED. High Pressure Coolant Injection has been administratively verified OPERABLE.

"Reactor Pressure is being maintained 550-1000 psig and being maintained with Reactor Water Clean Up Flow and Gland Seal System.

"Investigation into the cause of the valve failure is in-progress."

Unit 2 had been operating approximately 30 days prior to the scram reported previously in EN #40702. The licensee informed the NRC Resident Inspector.

* * * RETRACTION ON 6/23/04 AT 2036 EDT FROM GLEN MORROW TO ARLON COSTA * * *

"On April 24, 2004, Dresden made an ENS call due to the failure of Isolation Condenser valve 2-1301-3 to fully open and the subsequent determination that the Isolation Condenser was inoperable. The ENS call was made based on the decision that this was required by 10CFR50.72(b)(3)(v)(B), 'Any event or condition that at the time of discovery could have prevented fulfillment of the safety function of structures or systems that are needed to remove residual heat.'

"Isolation Condenser System operation is not credited in Dresden's accident analyses. Transients and Events treated as transients are listed under section 15.0.2.1 of the UFSAR. Accidents are described and analyzed under section 15.0.2.2 of the UFSAR. The isolation condenser is not credited for fulfilling safety function of removal of residual heat of any accident as described in section 15.0.2.2, Accidents. In accordance with the guidance contained in NUREG 1022, 'Event Reporting Guidelines 10CFR50.72 and 10CFR50.73,' Section 3.2.7, 'Event or Condition That Could Have Prevented Fulfillment of a Safety Function,' a functional failure of the Isolation Condenser System is not reportable under 10CFR50.72(b)(3)(v)(B). Therefore, Dresden is retracting this ENS call.

"This Isolation Condenser System event will be described in a Licensee Event Report in accordance with 10CFR50.73(a)(2)(i)(B), 'Any event or condition which was prohibited by the plant's Technical Specifications'"

The licensee notified the NRC Resident Inspector.

Notified R3DO (Kozak).