Skip to main content

Event Notification Report for April 16, 2004

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
04/15/2004 - 04/16/2004

EVENT NUMBERS
406774067840685

Power Reactor
Event Number: 40677
Facility: OCONEE
Region: 2     State: SC
Unit: [] [2] []
RX Type: [1] B&W-L-LP,[2] B&W-L-LP,[3] B&W-L-LP
NRC Notified By: MICHAEL DUNTON
HQ OPS Officer: HOWIE CROUCH
Notification Date: 04/16/2004
Notification Time: 08:47 [ET]
Event Date: 04/16/2004
Event Time: 01:05 [EDT]
Last Update Date: 04/16/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xii) - OFFSITE MEDICAL
Person (Organization):
STEPHEN CAHILL (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Refueling 0 Refueling
Event Text
TRANSPORT OF POTENTIALLY CONTAMINATED PERSON TO OFFSITE MEDICAL FACILITY

A vendor received a possible ankle fracture while working in the Unit 2 Reactor Building (RB). The injured person was descending a ladder and stepped on a roll of poly material and injured his ankle when the roll shifted.

Onsite medical assistance team responded and removed the individual from the RB and prepared him for transport to Oconee Memorial Hospital using a hospital ambulance. Due to the nature of the injury, the individual was unable to stand in the whole body frisker and was transported to the hospital as potentially contaminated. A licensee Radiation Protection Technician (RPT) accompanied the injured person in the ambulance to the hospital where it was determined that the individual was not contaminated.

At this time, there is no media/press interest and no press release is expected by the licensee.

The NRC Resident Inspector was notified by the licensee.


General Information or Other
Event Number: 40678
Rep Org: WESTINGHOUSE NUCLEAR SERVICES
Licensee: WESTINGHOUSE NUCLEAR SERVICES
Region: 0
City:   State:
County:
License #:
Agreement: N
Docket:
NRC Notified By: JIM GRESHAM
HQ OPS Officer: HOWIE CROUCH
Notification Date: 04/16/2004
Notification Time: 10:14 [ET]
Event Date: 04/16/2004
Event Time: 00:00 [EST]
Last Update Date: 04/16/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
21.21 - UNSPECIFIED PARAGRAPH
Person (Organization):
STEPHEN CAHILL (R2)
Event Text
PART 21 NOTIFICATION DUE TO POTENTIAL CRACKING IN B4C HYDRID CONTROL RODS

This issue concerns the potential for cracking in the tips of the Westinghouse designed B4C Hybrid Rod Cluster Control Assembly (RCCA) while in operation. Westinghouse supplied B4C Hybrid RCCAs are currently in use in the U.S. only at Tennessee Valley Authority's (TVA) Watts Bar Nuclear Plant.

Cracks in the hybrid RCCAs could result in a potential loss of B4C [a neutron absorber] from the RCCA if left uncorrected.

Westinghouse will review and revise its guidelines on the use and expected life of B4C Hybrid RCCAs to assure that this information is accurately reflected and communicated to its customers.


General Information or Other
Event Number: 40685
Rep Org: CALIFORNIA RADIATION CONTROL PRGM
Licensee: DECISIVE TESTING
Region: 4
City: SAN DIEGO   State: CA
County:
License #: 1836-37
Agreement: Y
Docket:
NRC Notified By: MICHAEL MAY
HQ OPS Officer: JAMIE HEISSERER
Notification Date: 04/19/2004
Notification Time: 20:23 [ET]
Event Date: 04/16/2004
Event Time: 13:15 [PDT]
Last Update Date: 04/22/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RUSSELL BYWATER (R4)
ROBERT PIERSON (NMSS)
Event Text
CALIFORNIA AGREEMENT STATE REPORT - EXPOSURE INCIDENT (<1 REM WHOLE BODY) INDUSTRIAL RADIOGRAPHER

At 2023 EDT, the following email was received from Decisive Testing:

"On April 16, 2004, a radiographer was working on a schedule 40 stainless steel 4" pipe. The Ir-192 radiography operation was being conducted inside a shielded x-ray room, but was considered by the licensee to be a temporary jobsite for materials radiography. The camera, the cable and collimator were inside the room while the operator and crank were located approximately 8' from the closed x-ray door. At 1:15 PM, the radiographer finished the 6th shot and reentered the room to prepare for the 7th shot. After setting up the 7th shot, he picked up his survey meter as he left the room (the meter had been placed on top of the camera when he entered the room) and noticed the meter was off scale. He exited the room and checked the position of the radiography source by attempting to crank it out, only to discover that he had failed to crank the source in after the 6th shot. His 0-200 millirem dosimeter was off scale and he was not wearing his alarming ratemeter. His dosimeter was sent in for processing by overnight mail. The licensee did a re-enactment and estimated the radiographer's whole body dose to be under 1 rem. The radiographer's extremity dose is estimated to be under 10 rem.

"Source: Industrial Nuclear, model 7, Ir-192 source assayed 10/16/03 and decayed to 17.9 Curies on 4-16-04). Camera: Amersham, model 660B, serial # B2928. Collimator: Industrial Radiography Maintenance & Supply, model - tungsten mini (side port) collimator (attenuation 1/16 for Ir-192).

"RHB responded to the site on Saturday, April 17, 2004 to interview the radiographer and RSO. The investigation is ongoing, but it does appear that neither the whole body nor extremity regulatory dose limits for the radiographer were exceeded."

* * * UPDATE 1500 EDT ON 4/22/04 FROM ROBERT GREGER TO S. SANDIN VIA FAX * * *

"The dosimeter results were received from Landauer on 4/21/04 and showed a whole body dose of 95 mrem for the radiographer in this event, which is consistent with a reenactment conducted by the licensee. Based on this information, the whole body dose did not exceed regulatory limits. The extremity dose to the radiographer is still under investigation."

Notified R4DO (Bywater) and NMSS (Torres).