Event Notification Report for March 31, 2004
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
03/30/2004 - 03/31/2004
EVENT NUMBERS
4063440644406304063140632
Hospital
Event Number: 40634
Rep Org: U.S. DEPT OF VA HP PROGRAM
Licensee: GREATER LOS ANGELES HEALTHCARE SYSTEM
Region: 4
City: LOS ANGELES State: CA
County:
License #: 03-23853-01VA
Agreement: Y
Docket:
NRC Notified By: EDWIN M. LEINHOLDT, PHD
HQ OPS Officer: ERIC THOMAS
Licensee: GREATER LOS ANGELES HEALTHCARE SYSTEM
Region: 4
City: LOS ANGELES State: CA
County:
License #: 03-23853-01VA
Agreement: Y
Docket:
NRC Notified By: EDWIN M. LEINHOLDT, PHD
HQ OPS Officer: ERIC THOMAS
Notification Date: 04/02/2004
Notification Time: 17:40 [ET]
Event Date: 03/31/2004
Event Time: 12:00 [PST]
Last Update Date: 04/02/2004
Notification Time: 17:40 [ET]
Event Date: 03/31/2004
Event Time: 12:00 [PST]
Last Update Date: 04/02/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
35.3045(a)(1) - DOSE <> PRESCRIBED DOSAGE
10 CFR Section:
35.3045(a)(1) - DOSE <> PRESCRIBED DOSAGE
Person (Organization):
DALE POWERS (R4)
MICHAEL PARKER (R3)
SCOTT MOORE (NMSS)
DALE POWERS (R4)
MICHAEL PARKER (R3)
SCOTT MOORE (NMSS)
POSSIBLE MEDICAL EVENT
The U.S. Department of Veteran's Affairs Health Physics Program (VA NHPP) notified the NRC of the following possible Medical Event at the VA Greater Los Angeles Healthcare System (GLAHCS), 11301 Wilshire Boulevard, Los Angeles, California 90073, a master material license permittee.
"On March 31, 2004, a permanent-implant prostate brachytherapy procedure was performed. 109 Iodine-125 seeds were implanted in the patient. A number of seeds were mistakenly placed in the patient's bladder. The seeds placed in the bladder have been recovered. At this time, it appears that the dose to the prostate was more than 20 percent less than that prescribed. The VA GLAHCS has taken initial action to prevent a recurrence. The VA NHPP intends to conduct a reactive inspection next week."
The VA NHPP is in the process of verifying that the licensee notified the patient of this occurrence.
Initial action taken to prevent recurrence was to cease performing this procedure until an investigation and root cause determination are complete.
The licensee has not yet determined whether any unintended damage was done to the bladder as a result of this procedure.
The U.S. Department of Veteran's Affairs Health Physics Program (VA NHPP) notified the NRC of the following possible Medical Event at the VA Greater Los Angeles Healthcare System (GLAHCS), 11301 Wilshire Boulevard, Los Angeles, California 90073, a master material license permittee.
"On March 31, 2004, a permanent-implant prostate brachytherapy procedure was performed. 109 Iodine-125 seeds were implanted in the patient. A number of seeds were mistakenly placed in the patient's bladder. The seeds placed in the bladder have been recovered. At this time, it appears that the dose to the prostate was more than 20 percent less than that prescribed. The VA GLAHCS has taken initial action to prevent a recurrence. The VA NHPP intends to conduct a reactive inspection next week."
The VA NHPP is in the process of verifying that the licensee notified the patient of this occurrence.
Initial action taken to prevent recurrence was to cease performing this procedure until an investigation and root cause determination are complete.
The licensee has not yet determined whether any unintended damage was done to the bladder as a result of this procedure.
Power Reactor
Event Number: 40644
Facility: MAINE YANKEE
Region: 1 State: ME
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: LARRY JEWETT
HQ OPS Officer: STEVE SANDIN
Region: 1 State: ME
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: LARRY JEWETT
HQ OPS Officer: STEVE SANDIN
Notification Date: 04/05/2004
Notification Time: 16:45 [ET]
Event Date: 03/31/2004
Event Time: 00:00 [EDT]
Last Update Date: 04/05/2004
Notification Time: 16:45 [ET]
Event Date: 03/31/2004
Event Time: 00:00 [EDT]
Last Update Date: 04/05/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
LAWRENCE DOERFLEIN (R1)
LAWRENCE DOERFLEIN (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Decommissioned | 0 | Decommissioned |
OFFSITE NOTIFICATION TO THE STATE OF MAINE CONCERNING AN UNSCHEDULED RAD RELEASE
"Notification made to government agencies (State of Maine Dept. of Human Services and Maine Emergency Management Agency) for unscheduled release of radioactive materials. On Wednesday 3/31 Maine Yankee had a minor release of 0.0000000470 curies of particulate material, which resulted in an exposure value of about 0.00000426 millirem. The cause of the release resulted from a minor fire during thermal cutting of structural material during the demolition process."
The licensee will inform their designated NRC Inspectors.
"Notification made to government agencies (State of Maine Dept. of Human Services and Maine Emergency Management Agency) for unscheduled release of radioactive materials. On Wednesday 3/31 Maine Yankee had a minor release of 0.0000000470 curies of particulate material, which resulted in an exposure value of about 0.00000426 millirem. The cause of the release resulted from a minor fire during thermal cutting of structural material during the demolition process."
The licensee will inform their designated NRC Inspectors.
Power Reactor
Event Number: 40630
Facility: POINT BEACH
Region: 3 State: WI
Unit: [1] [2] []
RX Type: [1] W-2-LP,[2] W-2-LP
NRC Notified By: JIM WILSON
HQ OPS Officer: ARLON COSTA
Region: 3 State: WI
Unit: [1] [2] []
RX Type: [1] W-2-LP,[2] W-2-LP
NRC Notified By: JIM WILSON
HQ OPS Officer: ARLON COSTA
Notification Date: 03/31/2004
Notification Time: 18:02 [ET]
Event Date: 03/31/2004
Event Time: 07:57 [CST]
Last Update Date: 03/31/2004
Notification Time: 18:02 [ET]
Event Date: 03/31/2004
Event Time: 07:57 [CST]
Last Update Date: 03/31/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
26.73 - FITNESS FOR DUTY
10 CFR Section:
26.73 - FITNESS FOR DUTY
Person (Organization):
MICHAEL PARKER (R3)
TERRY REIS (NRR)
MICHAEL PARKER (R3)
TERRY REIS (NRR)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 92 | Power Operation | 92 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
NON-LICENSED EMPLOYEE TESTED POSITIVE FOR ALCOHOL
A non-licensed supervisor tested positive for alcohol during a "for cause" test. A review of the employee's work concluded that the individual had not been engaged in safety-related activities. The individual has been denied access to Point Beach Nuclear Plant and to all other Nuclear Management Company, LLC (NMC) sites. Contact the Headquarters Operations Officer for additional details.
The licensee notified the NRC Resident Inspector.
A non-licensed supervisor tested positive for alcohol during a "for cause" test. A review of the employee's work concluded that the individual had not been engaged in safety-related activities. The individual has been denied access to Point Beach Nuclear Plant and to all other Nuclear Management Company, LLC (NMC) sites. Contact the Headquarters Operations Officer for additional details.
The licensee notified the NRC Resident Inspector.
Power Reactor
Event Number: 40631
Facility: SAINT LUCIE
Region: 2 State: FL
Unit: [1] [] []
RX Type: [1] CE,[2] CE
NRC Notified By: JEFF ABERNETHY
HQ OPS Officer: ARLON COSTA
Region: 2 State: FL
Unit: [1] [] []
RX Type: [1] CE,[2] CE
NRC Notified By: JEFF ABERNETHY
HQ OPS Officer: ARLON COSTA
Notification Date: 03/31/2004
Notification Time: 19:28 [ET]
Event Date: 03/31/2004
Event Time: 18:56 [EST]
Last Update Date: 03/31/2004
Notification Time: 19:28 [ET]
Event Date: 03/31/2004
Event Time: 18:56 [EST]
Last Update Date: 03/31/2004
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
Person (Organization):
JOEL MUNDAY (R2)
MICHAEL JOHNSON (NRR)
SUSAN FRANT (DIRO)
GIL AGUIRRE (DHS)
MIKE EACHES (FEMA)
JOEL MUNDAY (R2)
MICHAEL JOHNSON (NRR)
SUSAN FRANT (DIRO)
GIL AGUIRRE (DHS)
MIKE EACHES (FEMA)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Refueling | 0 | Refueling |
UNUSUAL EVENT DECLARED DUE TO REACTOR COOLANT SYSTEM LEAKAGE GREATER THAN 10 GPM
On 3/31/04, Saint Lucie Unit 1 was in a refueling outage when it experienced a leak-by which appeared to be at a Volume Control Tank to Hold Up Tank divert valve off the Shutdown Purification System. The Reactor Coolant System (RCS) leakage was greater than ten gallons per minute as indicated in the Control Room. The Facility declared an Unusual Event at 1856 EST since the RCS leakage was greater than ten but less fifty gallons per minute. Refueling activities were stopped as a result of the incident. The RCS leakage was isolated and the Unusual Event was terminated at 1915.
The licensee has notified local, state and other government agencies through the ring down phone system. The NRC Resident Inspector will be notified.
On 3/31/04, Saint Lucie Unit 1 was in a refueling outage when it experienced a leak-by which appeared to be at a Volume Control Tank to Hold Up Tank divert valve off the Shutdown Purification System. The Reactor Coolant System (RCS) leakage was greater than ten gallons per minute as indicated in the Control Room. The Facility declared an Unusual Event at 1856 EST since the RCS leakage was greater than ten but less fifty gallons per minute. Refueling activities were stopped as a result of the incident. The RCS leakage was isolated and the Unusual Event was terminated at 1915.
The licensee has notified local, state and other government agencies through the ring down phone system. The NRC Resident Inspector will be notified.
Power Reactor
Event Number: 40632
Facility: WATERFORD
Region: 4 State: LA
Unit: [3] [] []
RX Type: [3] CE
NRC Notified By: ROBERT MURILLO
HQ OPS Officer: MIKE RIPLEY
Region: 4 State: LA
Unit: [3] [] []
RX Type: [3] CE
NRC Notified By: ROBERT MURILLO
HQ OPS Officer: MIKE RIPLEY
Notification Date: 04/01/2004
Notification Time: 00:44 [ET]
Event Date: 03/31/2004
Event Time: 19:19 [CST]
Last Update Date: 04/01/2004
Notification Time: 00:44 [ET]
Event Date: 03/31/2004
Event Time: 19:19 [CST]
Last Update Date: 04/01/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(ii)(B) - UNANALYZED CONDITION
10 CFR Section:
50.72(b)(3)(ii)(B) - UNANALYZED CONDITION
Person (Organization):
DALE POWERS (R4)
DALE POWERS (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 3 | N | Y | 100 | Power Operation | 100 | Power Operation |
NEW WORST CASE SINGLE FAILURE MAY EXCEED 10 CFR 50.46 ACCEPTANCE CRITERION FOR SBLOCA
"A new worst case single failure was identified on 03-31-04 for the small break LOCA analysis of record due to a postulated loss of a DC power bus. This condition may result in the analysis of record exceeding 10 CFR 50.46 acceptance criterion of 2200 F when a small break LOCA with this failure is postulated.
"The current small break LOCA analysis of record assumes a single failure of one Emergency Diesel Generator (EDG) and credits flow from one charging pump. The peak cladding temperature for the analysis of record is 1929 F compared to the acceptance criteria of less than or equal to 2200 F. Half of the flow from a charging pump is assumed to go to the RCS and half is assumed to flow out the break. It was identified on 03-31-04 that a single failure of a DC power bus would be more limiting than the currently assumed single failure of an EDG. The DC bus failure will result in the EDG failure to start and also cause a charging loop isolation valve to the RCS to fail closed on loss of DC power. The other charging flow path to the RCS is on the assumed broken RCS leg so it is assumed to be spilled to the containment resulting in no charging flow to the RCS. Therefore, no charging flow would be delivered to the RCS as assumed in the current small break LOCA analysis of record. This condition has not been analyzed.
"Engineering judgment indicates that in the event of a small break accident the 10 CFR 50.46 acceptance criterion of 2200 F may be exceeded if the charging flow is not credited in the analysis of record. Therefore, this condition is reportable pursuant to 10 CFR 50.46 and 10 CFR 50.72(b)(3)(ii)(B).
"The current conservatism in the analysis of record and previous Westinghouse SBLOCA non-design basis scoping analyses using the NOTRUMP code provide assurance the plant is operating in a safe manner and is operable. The NOTRUMP analyses included cases with no changing flow. The peak clad temperature for these analyses were significantly below the acceptance criteria of 2200 F by more than 200 F. Thus, if an analysis were performed for Waterford 3 with the NOTRUMP code there is reasonable assurance due to the large margins that acceptable results would be achieved without any charging flow.
"This report is based on conservative judgment and available information. This report may be retracted based on the results of further evaluation."
The licensee notified the NRC Resident Inspector.
"A new worst case single failure was identified on 03-31-04 for the small break LOCA analysis of record due to a postulated loss of a DC power bus. This condition may result in the analysis of record exceeding 10 CFR 50.46 acceptance criterion of 2200 F when a small break LOCA with this failure is postulated.
"The current small break LOCA analysis of record assumes a single failure of one Emergency Diesel Generator (EDG) and credits flow from one charging pump. The peak cladding temperature for the analysis of record is 1929 F compared to the acceptance criteria of less than or equal to 2200 F. Half of the flow from a charging pump is assumed to go to the RCS and half is assumed to flow out the break. It was identified on 03-31-04 that a single failure of a DC power bus would be more limiting than the currently assumed single failure of an EDG. The DC bus failure will result in the EDG failure to start and also cause a charging loop isolation valve to the RCS to fail closed on loss of DC power. The other charging flow path to the RCS is on the assumed broken RCS leg so it is assumed to be spilled to the containment resulting in no charging flow to the RCS. Therefore, no charging flow would be delivered to the RCS as assumed in the current small break LOCA analysis of record. This condition has not been analyzed.
"Engineering judgment indicates that in the event of a small break accident the 10 CFR 50.46 acceptance criterion of 2200 F may be exceeded if the charging flow is not credited in the analysis of record. Therefore, this condition is reportable pursuant to 10 CFR 50.46 and 10 CFR 50.72(b)(3)(ii)(B).
"The current conservatism in the analysis of record and previous Westinghouse SBLOCA non-design basis scoping analyses using the NOTRUMP code provide assurance the plant is operating in a safe manner and is operable. The NOTRUMP analyses included cases with no changing flow. The peak clad temperature for these analyses were significantly below the acceptance criteria of 2200 F by more than 200 F. Thus, if an analysis were performed for Waterford 3 with the NOTRUMP code there is reasonable assurance due to the large margins that acceptable results would be achieved without any charging flow.
"This report is based on conservative judgment and available information. This report may be retracted based on the results of further evaluation."
The licensee notified the NRC Resident Inspector.