Event Notification Report for March 15, 2004
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
03/14/2004 - 03/15/2004
EVENT NUMBERS
4058840589405904059140672
Power Reactor
Event Number: 40588
Facility: NINE MILE POINT
Region: 1 State: NY
Unit: [] [2] []
RX Type: [1] GE-2,[2] GE-5
NRC Notified By: GLENN BRIDGES
HQ OPS Officer: MIKE RIPLEY
Region: 1 State: NY
Unit: [] [2] []
RX Type: [1] GE-2,[2] GE-5
NRC Notified By: GLENN BRIDGES
HQ OPS Officer: MIKE RIPLEY
Notification Date: 03/15/2004
Notification Time: 14:13 [ET]
Event Date: 03/15/2004
Event Time: 10:30 [EST]
Last Update Date: 03/15/2004
Notification Time: 14:13 [ET]
Event Date: 03/15/2004
Event Time: 10:30 [EST]
Last Update Date: 03/15/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - PLANT S/D REQD BY TS
10 CFR Section:
50.72(b)(2)(i) - PLANT S/D REQD BY TS
Person (Organization):
HAROLD GRAY (R1)
HAROLD GRAY (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | Y | 3 | Startup | 0 | Startup |
SHUTDOWN REQUIRED BY TECHNICAL SPECIFICATIONS DUE TO INOPERABLE ISOLATION INSTRUMENTATION
"During the planned shutdown for RFO9, the Reactor Water Clean Up (RWCU) Differential Flow Signals and the Reject Flow indicator did not receive a signal from the transmitters associated with the reject flow path from the reactor to the condenser in the RWCU system. Maintenance was contacted and the differential flow timers associated with these control loops were removed per operating procedure N2-OP-37 for the RWCU system and the Technical Specification Required Action for both required channels of Functions 4a and 4b in table 3.3.6.1-1 being inoperable was entered. This was required to allow venting of the transmitters and prevented an inadvertent isolation signal of the RWCU system.
"These primary containment isolation instruments were declared inoperable at 0830 on 3/15/2004. CONDITION B of LCO 3.3.6.1 was entered, which requires isolation capability to be restored in 1 hour. At 0930 on 3/15/04, CONDITIONS C and F were entered which require system isolation in one hour.
"At 1025, maintenance was completed; however, all post maintenance testing was not complete. At 1030, on 3/15/04 CONDITION F was not met and CONDITION H was entered. CONDITION H requires the unit be in MODE 3 in 12 hours and in MODE 4 in 36 hours.
"Since the unit was in a planned shutdown, with negative reactivity being inserted, it was unclear whether the entry into CONDITION H of Technical Specification 3.3.6.1 would have required actual insertion of negative reactivity for this situation. Thus, as a conservative action, NMPNS is reporting this event pursuant to 50.72(b)(2)(i) 'The initiation of any nuclear plant shutdown required by Technical Specifications.'
"The Differential flow timers were installed at 1129 on 3/15/04 with the plant in MODE 2. Operating procedures require a CHANNEL FUNCTION TEST prior to a declaration of operability, The CHANNEL FUNCTIONAL TEST is in progress."
The licensee notified the NRC Resident Inspector
"During the planned shutdown for RFO9, the Reactor Water Clean Up (RWCU) Differential Flow Signals and the Reject Flow indicator did not receive a signal from the transmitters associated with the reject flow path from the reactor to the condenser in the RWCU system. Maintenance was contacted and the differential flow timers associated with these control loops were removed per operating procedure N2-OP-37 for the RWCU system and the Technical Specification Required Action for both required channels of Functions 4a and 4b in table 3.3.6.1-1 being inoperable was entered. This was required to allow venting of the transmitters and prevented an inadvertent isolation signal of the RWCU system.
"These primary containment isolation instruments were declared inoperable at 0830 on 3/15/2004. CONDITION B of LCO 3.3.6.1 was entered, which requires isolation capability to be restored in 1 hour. At 0930 on 3/15/04, CONDITIONS C and F were entered which require system isolation in one hour.
"At 1025, maintenance was completed; however, all post maintenance testing was not complete. At 1030, on 3/15/04 CONDITION F was not met and CONDITION H was entered. CONDITION H requires the unit be in MODE 3 in 12 hours and in MODE 4 in 36 hours.
"Since the unit was in a planned shutdown, with negative reactivity being inserted, it was unclear whether the entry into CONDITION H of Technical Specification 3.3.6.1 would have required actual insertion of negative reactivity for this situation. Thus, as a conservative action, NMPNS is reporting this event pursuant to 50.72(b)(2)(i) 'The initiation of any nuclear plant shutdown required by Technical Specifications.'
"The Differential flow timers were installed at 1129 on 3/15/04 with the plant in MODE 2. Operating procedures require a CHANNEL FUNCTION TEST prior to a declaration of operability, The CHANNEL FUNCTIONAL TEST is in progress."
The licensee notified the NRC Resident Inspector
Power Reactor
Event Number: 40589
Facility: SEQUOYAH
Region: 2 State: TN
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: BILL HARRIS
HQ OPS Officer: MIKE RIPLEY
Region: 2 State: TN
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: BILL HARRIS
HQ OPS Officer: MIKE RIPLEY
Notification Date: 03/15/2004
Notification Time: 17:13 [ET]
Event Date: 03/15/2004
Event Time: 15:18 [EST]
Last Update Date: 03/15/2004
Notification Time: 17:13 [ET]
Event Date: 03/15/2004
Event Time: 15:18 [EST]
Last Update Date: 03/15/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
DAVID AYRES (R2)
DAVID AYRES (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | A/R | Y | 100 | Power Operation | 0 | Hot Standby |
AUTOMATIC REACTOR TRIP DUE TO MAIN GENERATOR ELECTRICAL FAULT SIGNAL
"At 1518 on 3/15/04, Unit 1 Reactor tripped due to a Main Turbine trip. The Main Turbine tripped due to a Main Generator electrical fault, Auxiliary Feedwater (AFW) started when both Main Feedwater Pumps tripped on Low Tave Feedwater isolation. The AFW start was expected on the Reactor Trip. All safety systems performed as required. Investigation is in progress to determine and correct the cause of this trip."
All control rods fully inserted; the electrical grid is stable; ECCS systems remain operable; decay heat is being removed via AFW and steam dumps. The licensee notified the NRC Resident Inspector.
"At 1518 on 3/15/04, Unit 1 Reactor tripped due to a Main Turbine trip. The Main Turbine tripped due to a Main Generator electrical fault, Auxiliary Feedwater (AFW) started when both Main Feedwater Pumps tripped on Low Tave Feedwater isolation. The AFW start was expected on the Reactor Trip. All safety systems performed as required. Investigation is in progress to determine and correct the cause of this trip."
All control rods fully inserted; the electrical grid is stable; ECCS systems remain operable; decay heat is being removed via AFW and steam dumps. The licensee notified the NRC Resident Inspector.
Power Reactor
Event Number: 40590
Facility: TURKEY POINT
Region: 2 State: FL
Unit: [3] [] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: ANDY NEWTON
HQ OPS Officer: MIKE RIPLEY
Region: 2 State: FL
Unit: [3] [] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: ANDY NEWTON
HQ OPS Officer: MIKE RIPLEY
Notification Date: 03/15/2004
Notification Time: 18:40 [ET]
Event Date: 03/15/2004
Event Time: 13:30 [EST]
Last Update Date: 03/15/2004
Notification Time: 18:40 [ET]
Event Date: 03/15/2004
Event Time: 13:30 [EST]
Last Update Date: 03/15/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
26.73 - FITNESS FOR DUTY
10 CFR Section:
26.73 - FITNESS FOR DUTY
Person (Organization):
DAVID AYRES (R2)
DAVID AYRES (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 3 | N | Y | 100 | Power Operation | 100 | Power Operation |
CONTRACT SUPERVISOR FITNESS FOR DUTY
At 1330 ET on 3/15/04, it was determined that a contract supervisor had tested positive for drugs on an access reinstatement urinalysis test. Access has been denied. The individual had only been badged for one day. A work review was conducted and no safety-related activities had been performed. Contact HOO for additional details.
The licensee has notified the NRC Resident Inspector.
At 1330 ET on 3/15/04, it was determined that a contract supervisor had tested positive for drugs on an access reinstatement urinalysis test. Access has been denied. The individual had only been badged for one day. A work review was conducted and no safety-related activities had been performed. Contact HOO for additional details.
The licensee has notified the NRC Resident Inspector.
Power Reactor
Event Number: 40591
Facility: MILLSTONE
Region: 1 State: CT
Unit: [] [2] []
RX Type: [1] GE-3,[2] CE,[3] W-4-LP
NRC Notified By: SUNYOUNG KWON
HQ OPS Officer: RICH LAURA
Region: 1 State: CT
Unit: [] [2] []
RX Type: [1] GE-3,[2] CE,[3] W-4-LP
NRC Notified By: SUNYOUNG KWON
HQ OPS Officer: RICH LAURA
Notification Date: 03/15/2004
Notification Time: 20:57 [ET]
Event Date: 03/15/2004
Event Time: 20:20 [EST]
Last Update Date: 03/15/2004
Notification Time: 20:57 [ET]
Event Date: 03/15/2004
Event Time: 20:20 [EST]
Last Update Date: 03/15/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
HAROLD GRAY (R1)
HAROLD GRAY (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | A/R | Y | 100 | Power Operation | 0 | Hot Standby |
AUTOMATIC REACTOR TRIP AT MILLSTONE 2 DUE TO SPURIOUS LOSS OF ONE MAIN FEED PUMP
The licensee reported that an automatic reactor trip occurred on 3/15/04 at 2020 EST due to the spurious trip of one main feed pump which caused a low steam generator water level trip signal. The plant has two main feed pumps. Operators reset the tripped main feed pump but steam generator levels didn't recover in time. The lowest level observed was in the "B" steam generator at 15% level as compared to the normal level of 65%. The trip setpoint is at 50% level. All control rods properly inserted into the core. The auxiliary feed water system automatically initiated as designed and expected. The plant remains stable in mode 3 while the licensee commenced the post trip review to determine the cause of the main feed pump trip. Decay heat removal was established using the AFW system to feed steam generators and bleed steam to the main condenser through the condenser dump valves.
The licensee notified the NRC Resident Inspector.
The licensee reported that an automatic reactor trip occurred on 3/15/04 at 2020 EST due to the spurious trip of one main feed pump which caused a low steam generator water level trip signal. The plant has two main feed pumps. Operators reset the tripped main feed pump but steam generator levels didn't recover in time. The lowest level observed was in the "B" steam generator at 15% level as compared to the normal level of 65%. The trip setpoint is at 50% level. All control rods properly inserted into the core. The auxiliary feed water system automatically initiated as designed and expected. The plant remains stable in mode 3 while the licensee commenced the post trip review to determine the cause of the main feed pump trip. Decay heat removal was established using the AFW system to feed steam generators and bleed steam to the main condenser through the condenser dump valves.
The licensee notified the NRC Resident Inspector.
Other Nuclear Material
Event Number: 40672
Rep Org: DEPARTMENT OF VETERANS AFFAIRS
Licensee: DEPARTMENT OF VETERANS AFFAIRS
Region: 3
City: ANN ARBOR State: MI
County:
License #: 03-23853-01VA
Agreement: N
Docket:
NRC Notified By: JOSEPH WISSING
HQ OPS Officer: BILL GOTT
Licensee: DEPARTMENT OF VETERANS AFFAIRS
Region: 3
City: ANN ARBOR State: MI
County:
License #: 03-23853-01VA
Agreement: N
Docket:
NRC Notified By: JOSEPH WISSING
HQ OPS Officer: BILL GOTT
Notification Date: 04/13/2004
Notification Time: 17:03 [ET]
Event Date: 03/15/2004
Event Time: 00:00 [EDT]
Last Update Date: 04/13/2004
Notification Time: 17:03 [ET]
Event Date: 03/15/2004
Event Time: 00:00 [EDT]
Last Update Date: 04/13/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X
10 CFR Section:
20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X
Person (Organization):
BRIAN MCDERMOTT (R1)
ROBERT PIERSON (NMSS)
MONTE PHILLIPS (R3)
BRIAN MCDERMOTT (R1)
ROBERT PIERSON (NMSS)
MONTE PHILLIPS (R3)
LOSS OF LICENSED MATERIAL
"The Department of Veterans Affairs is reporting a loss of licensed material. The loss occurred at a medical broad-scope permittee authorized under the master materials license issued to the Department of Veterans Affairs. The permittee is VA Boston Healthcare System, Boston, Massachusetts.
"The loss was discovered by the permittee Radiation Safety Officer (RSO) on March 15, 2004. The RSO discovered a container of solid animal waste containing approximately 350 micro-Curies of I-125 solid was disposed by transfer to a biological waste vendor and incinerated by the vendor as non-radioactive animal waste.
"The permittee does not anticipate any exposure to individuals based on the loss. The permittee has taken measures to prevent a recurrence of the loss.
"The basis for reporting the loss is under 10 CFR 20.2201(a)(ii) in that the permittee disposed of licensed material in a quantity greater than 10 times the quantity specified in 10 CFR 20, Appendix C, and is still missing at this time. The licensed material cannot be recovered.
"Per 10 CFR 20.2201(b), the Department of Veterans Affairs will evaluate the circumstances related to the loss and submit a written report to NRC, Region 3, within 30 days of this notification."
"The Department of Veterans Affairs is reporting a loss of licensed material. The loss occurred at a medical broad-scope permittee authorized under the master materials license issued to the Department of Veterans Affairs. The permittee is VA Boston Healthcare System, Boston, Massachusetts.
"The loss was discovered by the permittee Radiation Safety Officer (RSO) on March 15, 2004. The RSO discovered a container of solid animal waste containing approximately 350 micro-Curies of I-125 solid was disposed by transfer to a biological waste vendor and incinerated by the vendor as non-radioactive animal waste.
"The permittee does not anticipate any exposure to individuals based on the loss. The permittee has taken measures to prevent a recurrence of the loss.
"The basis for reporting the loss is under 10 CFR 20.2201(a)(ii) in that the permittee disposed of licensed material in a quantity greater than 10 times the quantity specified in 10 CFR 20, Appendix C, and is still missing at this time. The licensed material cannot be recovered.
"Per 10 CFR 20.2201(b), the Department of Veterans Affairs will evaluate the circumstances related to the loss and submit a written report to NRC, Region 3, within 30 days of this notification."