Event Notification Report for February 13, 2004
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
02/12/2004 - 02/13/2004
Power Reactor
Event Number: 40517
Facility: WOLF CREEK
Region: 4 State: KS
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: EDWIN TAYLOR
HQ OPS Officer: BILL GOTT
Region: 4 State: KS
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: EDWIN TAYLOR
HQ OPS Officer: BILL GOTT
Notification Date: 02/13/2004
Notification Time: 11:00 [ET]
Event Date: 02/13/2004
Event Time: 08:10 [CST]
Last Update Date: 02/13/2004
Notification Time: 11:00 [ET]
Event Date: 02/13/2004
Event Time: 08:10 [CST]
Last Update Date: 02/13/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
CHUCK CAIN (R4)
CHUCK CAIN (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | A/R | Y | 100 | Power Operation | 0 | Hot Standby |
RPS ACTUATION DUE TO LOW STEAM GENERATOR LEVEL
"At 0810 CST on 2-13-2004, all four Steam Generators alarmed with Steam Flow/Feed Flow Mismatch alarms, followed by indication of decreasing level in "D" Steam Generator. The reactor tripped approximately 20 seconds later on Lo-Lo level at 23.5% in "D" Steam Generator, as required. The cause of the loss of feedwater flow to "D" Steam Generator is under investigation.
"All plant safety related systems operated as required. The Steam Dumps, which function to remove excess heat as the secondary systems shutdown, exhibited control problems resulting in operation of the Steam Generator Atmospheric Relief Valves (ARVs) until the steam dump controller setpoint was adjusted and the steam dumps began to operate normally. The steam dumps are currently operating in automatic. The Steam Generator ARVs closed when the steam dumps began to operate.
"The auxiliary feedwater system actuated as designed, and a Feedwater Isolation signal was generated as designed on Lo-Lo Steam Generator Level.
"The plant is currently stable in Mode 3 at NOP and NOT while plant personnel investigate the causes of the trip and formulate the repair/restart plan."
Decay heat is currently being removed via the steam dumps. The plant electrical system responded normally and all emergency diesel generators remain in standby. There are no primary to secondary leaks. The licensee notified the NRC Resident Inspector.
"At 0810 CST on 2-13-2004, all four Steam Generators alarmed with Steam Flow/Feed Flow Mismatch alarms, followed by indication of decreasing level in "D" Steam Generator. The reactor tripped approximately 20 seconds later on Lo-Lo level at 23.5% in "D" Steam Generator, as required. The cause of the loss of feedwater flow to "D" Steam Generator is under investigation.
"All plant safety related systems operated as required. The Steam Dumps, which function to remove excess heat as the secondary systems shutdown, exhibited control problems resulting in operation of the Steam Generator Atmospheric Relief Valves (ARVs) until the steam dump controller setpoint was adjusted and the steam dumps began to operate normally. The steam dumps are currently operating in automatic. The Steam Generator ARVs closed when the steam dumps began to operate.
"The auxiliary feedwater system actuated as designed, and a Feedwater Isolation signal was generated as designed on Lo-Lo Steam Generator Level.
"The plant is currently stable in Mode 3 at NOP and NOT while plant personnel investigate the causes of the trip and formulate the repair/restart plan."
Decay heat is currently being removed via the steam dumps. The plant electrical system responded normally and all emergency diesel generators remain in standby. There are no primary to secondary leaks. The licensee notified the NRC Resident Inspector.
Power Reactor
Event Number: 40518
Facility: MONTICELLO
Region: 3 State: MN
Unit: [1] [] []
RX Type: [1] GE-3
NRC Notified By: LT. ANDERSON
HQ OPS Officer: JOHN MacKINNON
Region: 3 State: MN
Unit: [1] [] []
RX Type: [1] GE-3
NRC Notified By: LT. ANDERSON
HQ OPS Officer: JOHN MacKINNON
Notification Date: 02/13/2004
Notification Time: 11:49 [ET]
Event Date: 02/13/2004
Event Time: 07:30 [CST]
Last Update Date: 02/13/2004
Notification Time: 11:49 [ET]
Event Date: 02/13/2004
Event Time: 07:30 [CST]
Last Update Date: 02/13/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
ERIC DUNCAN (R3)
ERIC DUNCAN (R3)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
LOSS OF OFFSITE COMMUNICATIONS
At 0730, Monticello Nuclear Generating Plant became aware of the loss of incoming phone call capability. Investigation determined loss of ENS, HPN (FTS) lines were inoperable as well as the State of MN dedicated line. Commercial incoming calls (inoperable) out calls were operable. By 0930 CST all phone system were restored and determined operable. NRC Operations Center was notified of inoperable ENS phone via backup commercial line.
NRC Resident Inspector was notified of this by the licensee.
At 0730, Monticello Nuclear Generating Plant became aware of the loss of incoming phone call capability. Investigation determined loss of ENS, HPN (FTS) lines were inoperable as well as the State of MN dedicated line. Commercial incoming calls (inoperable) out calls were operable. By 0930 CST all phone system were restored and determined operable. NRC Operations Center was notified of inoperable ENS phone via backup commercial line.
NRC Resident Inspector was notified of this by the licensee.
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 40519
Facility: WATERFORD
Region: 4 State: LA
Unit: [3] [] []
RX Type: [3] CE
NRC Notified By: GREG SCOTT
HQ OPS Officer: ERIC THOMAS
Region: 4 State: LA
Unit: [3] [] []
RX Type: [3] CE
NRC Notified By: GREG SCOTT
HQ OPS Officer: ERIC THOMAS
Notification Date: 02/13/2004
Notification Time: 20:32 [ET]
Event Date: 02/13/2004
Event Time: 05:25 [CST]
Last Update Date: 03/15/2004
Notification Time: 20:32 [ET]
Event Date: 02/13/2004
Event Time: 05:25 [CST]
Last Update Date: 03/15/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
CHUCK CAIN (R4)
CHUCK CAIN (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 3 | N | Y | 100 | Power Operation | 100 | Power Operation |
24 HOUR NOTIFICATION PER LICENSEE CONDITION 2.F
"On February 13, 2004, Waterford 3 reactor power reached an estimated maximum reactor power level of 101.9% due to Atmospheric Dump Valve #2 (ADV#2) failing full open. ADV#2 failed open due to the control system setpoint failing low. Operations personnel promptly responded to the condition by reducing turbine load (5 megawatts per minute ) and manually closing ADV#2, to restore plant power. ADV#2 was open for less than a minute. Per the FSAR, this transient is an analyzed event and is bounded by the safety analyses. This event is being reported in accordance with Waterford 3 event notification and reporting procedure, UNT-006-010, which is more conservative than the guidance provided in NRC Inspection Procedure 61706. This event is being reported pursuant to Waterford 3 License Condition 2.F as a 24 hour notification."
The licensee notified the NRC Resident Inspector.
* * * RETRACTION FROM R. MURILLO TO M. RIPLEY 2100 ET ON 03/15/04 * * *
"On February 13, 2004, Waterford 3 provided a 24 hour notification to the NRC (reference EN# 40519) stating that due to a failed open atmospheric dump valve, plant reactor power level momentarily reached a value of 101.9%. The event was reported conservatively based on the guidance provided in the plant's event notification and reporting procedure. The procedure has been revised to incorporate the guidance provided by NRC inspection Procedure 61706, 'Core Thermal Power Evaluation.' Based on this guidance, reporting of events such as stated above (transient power increases) are not required unless reactor power level exceeds 102%. Accordingly, this event is not reportable as power level only reached 101.9% momentarily.
"Based on the above, the 24 hour notification made on 2/13/2004 is being retracted."
The licensee has notified the NRC Resident Inspector. Notified R4 DO (J. Clark)
"On February 13, 2004, Waterford 3 reactor power reached an estimated maximum reactor power level of 101.9% due to Atmospheric Dump Valve #2 (ADV#2) failing full open. ADV#2 failed open due to the control system setpoint failing low. Operations personnel promptly responded to the condition by reducing turbine load (5 megawatts per minute ) and manually closing ADV#2, to restore plant power. ADV#2 was open for less than a minute. Per the FSAR, this transient is an analyzed event and is bounded by the safety analyses. This event is being reported in accordance with Waterford 3 event notification and reporting procedure, UNT-006-010, which is more conservative than the guidance provided in NRC Inspection Procedure 61706. This event is being reported pursuant to Waterford 3 License Condition 2.F as a 24 hour notification."
The licensee notified the NRC Resident Inspector.
* * * RETRACTION FROM R. MURILLO TO M. RIPLEY 2100 ET ON 03/15/04 * * *
"On February 13, 2004, Waterford 3 provided a 24 hour notification to the NRC (reference EN# 40519) stating that due to a failed open atmospheric dump valve, plant reactor power level momentarily reached a value of 101.9%. The event was reported conservatively based on the guidance provided in the plant's event notification and reporting procedure. The procedure has been revised to incorporate the guidance provided by NRC inspection Procedure 61706, 'Core Thermal Power Evaluation.' Based on this guidance, reporting of events such as stated above (transient power increases) are not required unless reactor power level exceeds 102%. Accordingly, this event is not reportable as power level only reached 101.9% momentarily.
"Based on the above, the 24 hour notification made on 2/13/2004 is being retracted."
The licensee has notified the NRC Resident Inspector. Notified R4 DO (J. Clark)