Skip to main content

Event Notification Report for February 09, 2004

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
02/08/2004 - 02/09/2004

EVENT NUMBERS
4050940510

Power Reactor
Event Number: 40509
Facility: SUSQUEHANNA
Region: 1     State: PA
Unit: [1] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: GRANT FERNSLER
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 02/09/2004
Notification Time: 19:52 [ET]
Event Date: 02/09/2004
Event Time: 19:00 [EST]
Last Update Date: 02/09/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
KENNETH JENISON (R1)
GENE IMBRO (NRR)
SUSAN FRANT (IRO)
BETH HAYDEN (PA)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 85 Power Operation 85 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
VOLUNTARY REPORT OF A PRESS RELEASE

On 2/9/04 PPL issued a Press Release concerning the NRC decision to send an Inspection team to investigate the cause of the loose bolts found on one of the Emergency Diesel Generator and two other events involving Emergency Diesel Generators at the Susquehanna site.

The NRC Resident Inspector was notified.


Other Nuclear Material
Event Number: 40510
Rep Org: PMK GROUP
Licensee: PMK GROUP
Region: 1
City: EAST ORANGE   State: NJ
County:
License #: 29-27828-01
Agreement: N
Docket:
NRC Notified By: ROMAN BURAK
HQ OPS Officer: RICH LAURA
Notification Date: 02/10/2004
Notification Time: 11:02 [ET]
Event Date: 02/09/2004
Event Time: 12:30 [EST]
Last Update Date: 02/10/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
ROBERTO TORRES (NMSS)
KENNETH JENISON (R1)
Event Text
DAMAGED/MISSING DENSITY GAUGE AT DEMOLITION SITE

The licensee reported a damaged/missing Humboldt Density Gauge at a demolition site located in East Orange, New Jersey near the intersection of Gould Avenue and Steuben Street. The gauge was a model HS-5001 with a serial number of 2822. The source contains less than 11 millicuries of Cs-137 and less than 44 millicuries of Am-241:Be. Only the gauge faceplate was found and no other parts including the radioactive source. The licensee performed a radiological survey and did not detect any levels greater than background. The licensee started interviews to determine what happened and where the remaining parts are located. The licensee notified the NRC Region I office on 2/9/04 and two NRC inspectors were arriving onsite at the time of this report.