Event Number: 40494
Facility: DRESDEN
Region: 3     State: IL
Unit: [] [2] []
RX Type: [1] GE-1,[2] GE-3,[3] GE-3
NRC Notified By: BILL HIGGINS
HQ OPS Officer: JOHN MacKINNON
Notification Date: 02/01/2004
Notification Time: 09:54 [ET]
Event Date: 02/01/2004
Event Time: 04:00 [CST]
Last Update Date: 02/01/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
PATRICK LOUDEN (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 96 Power Operation 96 Power Operation
Event Text
HIGH PRESSURE COOLANT INJECTION DECLARED INOPERABLE BUT REMAINS AVAILABLE.

During the Unit 3 scram on 01/30/04 the response of the feedwater level control system caused the RPV (Reactor Pressure Vessel) level to increase higher than expected. RPV level rose above the HPCI steam line. Calculations showed approximately 60 gallons of water entered the steam line.

This response could adversely affect the HPCI system should the same type of event occur and FWLC (Feedwater Level Control) respond the same way on Unit 2. Based on this information and no reasonable assurance that the same response will not occur, the Unit 2 HPCI system is conservatively being declared inoperable. HPCI remains available. Entering Tech Spec 3.5.1 Required Action F.1 (Isolation Condenser is OPERABLE) and F.2 (Restore HPCI to Operable status within 14 days).

A modification is being prepared to change the response of FWLC to preclude this adverse response during a transient.

The NRC Resident Inspector will be notified.


Power Reactor
Event Number: 40495
Facility: LASALLE
Region: 3     State: IL
Unit: [] [2] []
RX Type: [1] GE-5,[2] GE-5
NRC Notified By: THOMAS DEAN
HQ OPS Officer: JOHN MacKINNON
Notification Date: 02/02/2004
Notification Time: 02:25 [ET]
Event Date: 02/01/2004
Event Time: 22:34 [CST]
Last Update Date: 02/02/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
PATRICK LOUDEN (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
ONE HALF SCRAM SIGNAL DUE TO THE LOSS OF THE "B" REACTOR PROTECTION SYSTEM BUS.

This report is being made pursuant to 10 CFR50.72(b)(3)(iv)(A), system actuation not including Reactor Protection System; due to a trip of the "D" Electric Power Monitoring Assembly on the "B" Reactor Protection System Motor Generator set resulting in a trip of the "B" Reactor Protection System bus. The loss of "B" Reactor Protection System bus caused the actuation of multiple Primary Containment Isolation Systems. Station abnormal procedures have been entered and the plant stabilized. The system actuations that occurred have been verified and restorations of these systems are in progress. Troubleshooting plans are being developed to determine cause of the trip and to correct the deficient condition.


The NRC Resident Inspector was notified of this event by the Licensee.