Power Reactor
Event Number: 40432
Facility: SEABROOK
Region: 1     State: NH
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: DENNIS BEAMIS
HQ OPS Officer: RICH LAURA
Notification Date: 01/08/2004
Notification Time: 18:45 [ET]
Event Date: 01/08/2004
Event Time: 17:58 [EST]
Last Update Date: 01/09/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
JAMES NOGGLE (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
OFFSITE NOTIFICATION AT SEABROOK

The licensee reported that the upper lights on the meteorological tower were not working. The licensee made an offsite notification to the FAA and will initiate corrective actions.

The licensee notified the NRC resident inspector.


* * * UPDATE ON 01/09/04 @ 0859 BY RITTER TO GOULD * * * RETRACTION

The licensee is retracting this notification after a further review of the reporting requirements determined that the notification was unnecessary. The condition reported to other government agencies was not related to the radiological health and safety of the public or onsite personnel or the protection of the environment.

The NRC Resident Inspector was informed.

Notified Reg 1 RDO (Noggle)


Power Reactor
Event Number: 40433
Facility: OCONEE
Region: 2     State: SC
Unit: [1] [] []
RX Type: [1] B&W-L-LP,[2] B&W-L-LP,[3] B&W-L-LP
NRC Notified By: ROY SMITH
HQ OPS Officer: RICH LAURA
Notification Date: 01/08/2004
Notification Time: 19:12 [ET]
Event Date: 01/08/2004
Event Time: 15:02 [EST]
Last Update Date: 01/08/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - PLANT S/D REQD BY TS
Person (Organization):
PAUL FREDRICKSON (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 28 Power Operation 17 Power Operation
Event Text
TS REQUIRED SHUTDOWN AT OCONEE 1 DUE TO UNIDENTIFIED RCS LEAKAGE

"Event Description: Reactor Coolant System, (RCS) Leakage in excess of TS limits. RCS leakage calculations have shown a gradual increase in leakage following Unit l start-up from a refueling outage. On 1/7/2004 @ 1800 hours an RCS leakage calculation was performed with the calculated leak rate at 0.300 gpm. On 1/8/2004 @ 1225 hours, with Reactor power at approximately 26% Rated Thermal Power (RTP), leakage had increased to 0.778 gpm. Personnel have entered containment and have determined the source to be within the A steam generator cavity. At 1312 hours a power reduction to 17% RTP was initiated to reduce dose sufficiently to allow entry into the cavity in an attempt to identify the exact leak source. On 1/8/2004 @ 1502 hours, the leak rate was calculated to be one gpm which exceeds the allowed leakage for unidentified leakage. Units 2 and 3 are unaffected and remain at 100% RTP.

"Initial Safety Significance: The measured leakage is well within the capacity of the normal RCS make-up system. The increase in leakage rate has been slow, and is not expected to increase significantly prior to completion of the TS required shutdown. The leakage is confined inside containment. At this time, there has been NO RADIOLOGICAL RELEASE associated with this event.

"NOTE: Entry into the emergency plan is not required unless the leakage is => 10 gpm unidentified or => 25 gpm identified, the current leakage is significantly below those limits.

"Corrective Action(s)= Unit shutdown per TS is in progress. Isolation or repair of the leak will be evaluated once the location of the leak source is determined. TS 3.4.13 allows 4 hours to reduce leakage within limits. If the source remains unidentified and leakage remains above limits, the TS requires shutdown to Mode 3 within 12 hours and to Mode 5 within 36 hours."

The NRC resident inspector was notified.