Event Notification Report for December 17, 2003
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
12/16/2003 - 12/17/2003
EVENT NUMBERS
40396403974039840399
Power Reactor
Event Number: 40396
Facility: SAN ONOFRE
Region: 4 State: CA
Unit: [] [] [3]
RX Type: [1] W-3-LP,[2] CE,[3] CE
NRC Notified By: JOHN BRAISTED
HQ OPS Officer: HOWIE CROUCH
Region: 4 State: CA
Unit: [] [] [3]
RX Type: [1] W-3-LP,[2] CE,[3] CE
NRC Notified By: JOHN BRAISTED
HQ OPS Officer: HOWIE CROUCH
Notification Date: 12/17/2003
Notification Time: 08:35 [ET]
Event Date: 12/17/2003
Event Time: 03:15 [PST]
Last Update Date: 12/17/2003
Notification Time: 08:35 [ET]
Event Date: 12/17/2003
Event Time: 03:15 [PST]
Last Update Date: 12/17/2003
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - PLANT S/D REQD BY TS
10 CFR Section:
50.72(b)(2)(i) - PLANT S/D REQD BY TS
Person (Organization):
PHIL HARRELL (R4)
TERRY REIS (NRR)
TIM MCGINTY (IRO)
GIRIJA SHUKLA (NRR)
PHIL HARRELL (R4)
TERRY REIS (NRR)
TIM MCGINTY (IRO)
GIRIJA SHUKLA (NRR)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 3 | N | Y | 100 | Power Operation | 80 | Power Operation |
TECHNICAL SPECIFICATION REQUIRED SHUTDOWN DUE TO LOSS OF BOTH TRAINS OF SAFETY INJECTION
The following information was obtained from the licensee via facsimile:
"1. SYSTEMS AFFECTED: High Pressure Safety Injection (HPSI), Low Pressure Safety Injection (LPSI), Recirculation Actuation [System] (RAS), Containment Spray (CS).
"2. ACTUATIONS AND THEIR INITIATING SIGNALS: None
"3. CAUSES: 400 [volt] Motor Control Center (MCC) 3BE deenergized due to an overcurrent condition on the 'A' train 1E bus. 'B' train equipment is cleared for maintenance causing Technical Specification 3.0.3 entry.
"4. EFFECT OF EVENT ON PLANT: Both trains of Safety Injection equipment inoperable with no flow capability requiring plant shutdown.
"5. ACTIONS TAKEN OR PLANNED: Shutdown commenced at 0410 [PST]. MCC 3BE is stripped and loads will be checked for faults while attempting to restore the bus. Train 'B' equipment will be restored as soon as possible.
"Continuation Sheet: Power/Mode will be reduced per T.S. 3.0.3 action until MCC 3BE loads restored or Tr[ain] 'B' equipment returned to service. [Plant required to be in] Mode 3 [within] 7 hrs, Mode 4 [within] 13 hrs. [and] Mode 5 [within] 37 hrs. No abnormal electrical lineups. No effect on Unit 2. LPSI pump/valves will need to be restored to allow Mode 5 entry."
Plant personnel suspect a problem with the 1E bus feeder breaker. A new breaker will be installed after testing is completed. Bus loads are in the process of being checked for problems. At the time of the initial call, plant power was at 80% and decreasing at approximately 10% per hour. At 0939 PST, plant power was at 71% and decreasing. The 1E bus have been meggered with no problems found. Battery chargers are currently not operating due to loss of the buses but not expected to be a problem since DC loads are very low during mode 1 operations.
The licensee has notified the NRC Resident Inspector.
The following information was obtained from the licensee via facsimile:
"1. SYSTEMS AFFECTED: High Pressure Safety Injection (HPSI), Low Pressure Safety Injection (LPSI), Recirculation Actuation [System] (RAS), Containment Spray (CS).
"2. ACTUATIONS AND THEIR INITIATING SIGNALS: None
"3. CAUSES: 400 [volt] Motor Control Center (MCC) 3BE deenergized due to an overcurrent condition on the 'A' train 1E bus. 'B' train equipment is cleared for maintenance causing Technical Specification 3.0.3 entry.
"4. EFFECT OF EVENT ON PLANT: Both trains of Safety Injection equipment inoperable with no flow capability requiring plant shutdown.
"5. ACTIONS TAKEN OR PLANNED: Shutdown commenced at 0410 [PST]. MCC 3BE is stripped and loads will be checked for faults while attempting to restore the bus. Train 'B' equipment will be restored as soon as possible.
"Continuation Sheet: Power/Mode will be reduced per T.S. 3.0.3 action until MCC 3BE loads restored or Tr[ain] 'B' equipment returned to service. [Plant required to be in] Mode 3 [within] 7 hrs, Mode 4 [within] 13 hrs. [and] Mode 5 [within] 37 hrs. No abnormal electrical lineups. No effect on Unit 2. LPSI pump/valves will need to be restored to allow Mode 5 entry."
Plant personnel suspect a problem with the 1E bus feeder breaker. A new breaker will be installed after testing is completed. Bus loads are in the process of being checked for problems. At the time of the initial call, plant power was at 80% and decreasing at approximately 10% per hour. At 0939 PST, plant power was at 71% and decreasing. The 1E bus have been meggered with no problems found. Battery chargers are currently not operating due to loss of the buses but not expected to be a problem since DC loads are very low during mode 1 operations.
The licensee has notified the NRC Resident Inspector.
Power Reactor
Event Number: 40397
Facility: LASALLE
Region: 3 State: IL
Unit: [1] [2] []
RX Type: [1] GE-5,[2] GE-5
NRC Notified By: KEITH TABER
HQ OPS Officer: GERRY WAIG
Region: 3 State: IL
Unit: [1] [2] []
RX Type: [1] GE-5,[2] GE-5
NRC Notified By: KEITH TABER
HQ OPS Officer: GERRY WAIG
Notification Date: 12/17/2003
Notification Time: 13:03 [ET]
Event Date: 12/17/2003
Event Time: 11:30 [CST]
Last Update Date: 12/17/2003
Notification Time: 13:03 [ET]
Event Date: 12/17/2003
Event Time: 11:30 [CST]
Last Update Date: 12/17/2003
Emergency Class: NON EMERGENCY
10 CFR Section:
20.1906(d)(2) - EXTERNAL RAD LEVELS > LIMITS
10 CFR Section:
20.1906(d)(2) - EXTERNAL RAD LEVELS > LIMITS
Person (Organization):
THOMAS KOZAK (R3)
THOMAS KOZAK (R3)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
REFUELING EQUIPMENT RECEIVED AT LASALLE STATION EXCEEDING RADIATION LIMITS
"This notification is being made in pursuant to Exelon Reportability manual RAD 1.11 and 10 CFR 20.1906(d)(2). At 11:30 CST on 12/17/03, Radiation Protection Technician notified the Shift Manager that a Radiation Shipment (03-1216-02) was received at LaSalle from Duratek (Memphis, TN) that exceeded 200 mrem/hr on the external surface of the package. In accordance with 10 CFR 71.47(b)(1) the package was not in a closed transport vehicle and thus did not meet the exclusion to allow the package to be greater than 200 mrem/hr and less than 1000 mrem/hr. The as found readings on the package were measured at 211 mrem/hr and verified with a second instrument at 207 mrem/hr. The package was also surveyed for contamination and found to be free of loose contamination. Pursuant to 10 CFR 20.1906(d)(2), the final delivery carrier (R&R Trucking Co) was also notified of this event."
The licensee has notified the NRC Resident Inspector.
"This notification is being made in pursuant to Exelon Reportability manual RAD 1.11 and 10 CFR 20.1906(d)(2). At 11:30 CST on 12/17/03, Radiation Protection Technician notified the Shift Manager that a Radiation Shipment (03-1216-02) was received at LaSalle from Duratek (Memphis, TN) that exceeded 200 mrem/hr on the external surface of the package. In accordance with 10 CFR 71.47(b)(1) the package was not in a closed transport vehicle and thus did not meet the exclusion to allow the package to be greater than 200 mrem/hr and less than 1000 mrem/hr. The as found readings on the package were measured at 211 mrem/hr and verified with a second instrument at 207 mrem/hr. The package was also surveyed for contamination and found to be free of loose contamination. Pursuant to 10 CFR 20.1906(d)(2), the final delivery carrier (R&R Trucking Co) was also notified of this event."
The licensee has notified the NRC Resident Inspector.
General Information or Other
Event Number: 40398
Rep Org: ARIZONA RADIATION REGULATORY AGENCY
Licensee: NINYO & MOORE
Region: 4
City: PHOENIX State: AZ
County:
License #: 07-460
Agreement: Y
Docket:
NRC Notified By: WILLIAM WRIGHT
HQ OPS Officer: ERIC THOMAS
Licensee: NINYO & MOORE
Region: 4
City: PHOENIX State: AZ
County:
License #: 07-460
Agreement: Y
Docket:
NRC Notified By: WILLIAM WRIGHT
HQ OPS Officer: ERIC THOMAS
Notification Date: 12/17/2003
Notification Time: 15:17 [ET]
Event Date: 12/17/2003
Event Time: 12:30 [MST]
Last Update Date: 08/30/2004
Notification Time: 15:17 [ET]
Event Date: 12/17/2003
Event Time: 12:30 [MST]
Last Update Date: 08/30/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
PHIL HARRELL (R4)
JOHN HICKEY (NMSS)
VICTOR GONZALEZ (MEX)
PHIL HARRELL (R4)
JOHN HICKEY (NMSS)
VICTOR GONZALEZ (MEX)
AGREEMENT STATE REPORT - STOLEN TROXLER GAUGE
On 12/16/03 at approximately 1230 MST, a soil moisture density gauge was stolen from the rear of a technician's pickup truck while he was stopped for lunch at 23rd Street and Indian School. The gauge was contained in a yellow transport case and is a Troxler Model 3430, Serial Number 33308. The gauge contains approximately 10 millicuries of Cesium-137, and 40 millicuries of Americium-241. The theft of the gauge was reported to the Arizona Radiation Regulatory Agency at approximately 1325 MST.
The licensee issued a press release offering a $500.00 reward for the recovery of the gauge.
The Arizona Radiation Regulatory Agency and the licensee will continue to investigate this occurrence and report further.
The FBI, States of CA, NV, NM, CO, and the country of Mexico are being notified of this event.
* * * UPDATE PROVIDED VIA FAX BY A. GODWIN TO JEFF ROTTON AT 1405 EDT ON 08/30/04 * * *
"After working hours on 08/27/04, the [Arizona Radiation Regulatory] Agency was notified by the licensee, that a non-employee had contacted them and returned the missing Troxler Model 3430 gauge.
"The FBI, States of CA, NV, NM, CO and the country of Mexico are being notified of the recovery.
Notified R4DO (Jones), NMSS (Brach), and Mexico (V. Gonzalez).
On 12/16/03 at approximately 1230 MST, a soil moisture density gauge was stolen from the rear of a technician's pickup truck while he was stopped for lunch at 23rd Street and Indian School. The gauge was contained in a yellow transport case and is a Troxler Model 3430, Serial Number 33308. The gauge contains approximately 10 millicuries of Cesium-137, and 40 millicuries of Americium-241. The theft of the gauge was reported to the Arizona Radiation Regulatory Agency at approximately 1325 MST.
The licensee issued a press release offering a $500.00 reward for the recovery of the gauge.
The Arizona Radiation Regulatory Agency and the licensee will continue to investigate this occurrence and report further.
The FBI, States of CA, NV, NM, CO, and the country of Mexico are being notified of this event.
* * * UPDATE PROVIDED VIA FAX BY A. GODWIN TO JEFF ROTTON AT 1405 EDT ON 08/30/04 * * *
"After working hours on 08/27/04, the [Arizona Radiation Regulatory] Agency was notified by the licensee, that a non-employee had contacted them and returned the missing Troxler Model 3430 gauge.
"The FBI, States of CA, NV, NM, CO and the country of Mexico are being notified of the recovery.
Notified R4DO (Jones), NMSS (Brach), and Mexico (V. Gonzalez).
General Information or Other
Event Number: 40399
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: GUIDANT CORPORATION
Region: 4
City: PERLAND State: TX
County:
License #: L05178
Agreement: Y
Docket:
NRC Notified By: HELEN WATKINS (email)
HQ OPS Officer: GERRY WAIG
Licensee: GUIDANT CORPORATION
Region: 4
City: PERLAND State: TX
County:
License #: L05178
Agreement: Y
Docket:
NRC Notified By: HELEN WATKINS (email)
HQ OPS Officer: GERRY WAIG
Notification Date: 12/17/2003
Notification Time: 19:03 [ET]
Event Date: 12/17/2003
Event Time: 00:00 [CST]
Last Update Date: 12/17/2003
Notification Time: 19:03 [ET]
Event Date: 12/17/2003
Event Time: 00:00 [CST]
Last Update Date: 12/17/2003
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
PHIL HARRELL (R4)
JOHN HICKEY (NMSS)
PHIL HARRELL (R4)
JOHN HICKEY (NMSS)
AGREEMENT STATE - POTENTIAL LEAK ON P-32 SOURCE WIRE
The following is taken from an email received from the State of Texas, Department of Health:
"This is a Texas agreement state incident being forwarded based on a 5 day report requirement for a leaking source. (Incident 8083) The Licensee reporting the incident is Guidant located in Pearland, TX, L05178. More information is anticipated. This is a preliminary report.
"Today a returned P-32 [Phosphorus-32] source wire was received at our Pearland facility. This facility is authorized for radioactive material use under license number L05178. The source wires we manufacture are registered with the TX-BRC as TX-1070-S-101-S. These source wires are sent to our user sites [hospitals] and returned to Pearland for decay and disposal.
"The active portion of the source wire was wiped during the receipt survey. Approximately, 8.0 nCi [nanocuries] of activity was removed at that time. The source wire was stored for investigation at that time.
"A later wipe showed removable activity of approximately 0.5 nCi [nanocuries]. We will continue to investigate the source wire to determine if the wire is leaking or if the contamination was from another source."
The following is taken from an email received from the State of Texas, Department of Health:
"This is a Texas agreement state incident being forwarded based on a 5 day report requirement for a leaking source. (Incident 8083) The Licensee reporting the incident is Guidant located in Pearland, TX, L05178. More information is anticipated. This is a preliminary report.
"Today a returned P-32 [Phosphorus-32] source wire was received at our Pearland facility. This facility is authorized for radioactive material use under license number L05178. The source wires we manufacture are registered with the TX-BRC as TX-1070-S-101-S. These source wires are sent to our user sites [hospitals] and returned to Pearland for decay and disposal.
"The active portion of the source wire was wiped during the receipt survey. Approximately, 8.0 nCi [nanocuries] of activity was removed at that time. The source wire was stored for investigation at that time.
"A later wipe showed removable activity of approximately 0.5 nCi [nanocuries]. We will continue to investigate the source wire to determine if the wire is leaking or if the contamination was from another source."