Event Notification Report for October 23, 2003

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
10/22/2003 - 10/23/2003

EVENT NUMBERS
402724027340275

!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 40272
Facility: SUSQUEHANNA
Region: 1     State: PA
Unit: [1] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: GORDON ROBINSON
HQ OPS Officer: JEFF ROTTON
Notification Date: 10/23/2003
Notification Time: 21:30 [ET]
Event Date: 10/23/2003
Event Time: 16:40 [EDT]
Last Update Date: 12/12/2003
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
LAWRENCE DOERFLEIN (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
NONEMERGENCY NOTIFICATION DUE TO FAILURE TO MAINTAIN CONTROL STRUCTURE HABITABILITY ENVELOPE

"During routine monitoring, Control Room personnel noted control structure pressure differential was below the 1/8" [inches of water pressure] required to maintain the Control Structure Habitability Envelope. A walkdown of the Control Structure and initial investigation has revealed no obvious problems that would cause the low positive pressure condition. Due to the inability of the Control Structure HVAC to maintain a positive pressure, both trains of Control Room Emergency Outside Air Supply system were declared inoperable. This is considered a Loss of Safety Function in accordance with 10 CFR 50.72(b)(3)(v)(D)."

The licensee has notified the NRC Resident Inspector.

* * * * RETRACTION FROM A. FITCH TO M. RIPLEY 1343 ET 12/12/03 * * * *

"At the time of the original 8-hour ENS notification was made, both trains of the Control Room Emergency Outside Air Supply (CREOAS) system were declared inoperable due to the failure of the Control Structure HVAC system to maintain the control structure habitability envelope at a pressure greater than + 1/8" w.g. [water gauge] with respect to outside atmosphere.

"Subsequent to this event, an evaluation was performed which determined that the requirement to maintain the control structure habitability envelope at a pressure greater than + 1/8" w.g. is only applicable during emergency operating conditions. Under emergency conditions, the CREOAS system, in conjunction with the Control Structure HVAC system, is required to maintain control structure pressure greater than + 1/8" w.g. in accordance with Technical Specification 3.7.3. However, during normal plant operation, the design function of the Control Structure HVAC system is to maintain the habitability envelope at a positive pressure above atmospheric. No specific value is required. Differential pressure readings for the control structure indicated that pressure was maintained above atmospheric at the time of this event.

"On October 24, 2003, surveillance testing successfully demonstrated that the Control Structure HVAC and CREOAS systems were capable of maintaining the control structure habitability envelope at a pressure greater than + 1/8" w.g. As such, there was no loss of safety function."

The licensee has notified the NRC Resident Inspector. Notified R1DO (A. Della Greca)


Power Reactor
Event Number: 40273
Facility: COLUMBIA GENERATING STATION
Region: 4     State: WA
Unit: [2] [] []
RX Type: [2] GE-5
NRC Notified By: MOT HEDGES
HQ OPS Officer: JEFF ROTTON
Notification Date: 10/23/2003
Notification Time: 21:39 [ET]
Event Date: 10/23/2003
Event Time: 17:43 [PDT]
Last Update Date: 10/23/2003
Emergency Class: NON EMERGENCY
10 CFR Section:
73.71(b)(1) - SAFEGUARDS REPORTS
Person (Organization):
DAVID LOVELESS (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
DEGRADED SAFEGUARDS CONDITION

Discovered vulnerability in a safeguard system that could allow unauthorized or undetected access to safeguards material. Compensatory measures have been employed.

The licensee notified the NRC Resident Inspector. Contact Headquarters Operations Officer for additional details.


General Information or Other
Event Number: 40275
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: DRASH CONSULTING ENGINEERS, INC
Region: 4
City: SAN ANTONIO   State: TX
County:
License #: L04724
Agreement: Y
Docket:
NRC Notified By: HELEN WATKINS
HQ OPS Officer: JEFF ROTTON
Notification Date: 10/24/2003
Notification Time: 17:19 [ET]
Event Date: 10/23/2003
Event Time: 07:30 [CDT]
Last Update Date: 10/24/2003
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
DAVID LOVELESS (R4)
DANIEL GILLEN (NMSS)
Event Text
AGREEMENT STATE NOTIFICATION REGARDING STOLEN GAUGE

A Troxler gauge, Model 3241C, serial # 2547 with a 100 millicurie Am-241/Be source serial # 558906 was stolen from the back of gauge operator's pickup truck. The truck was parked at the gauge operator's residence overnight. The lock, chains, and broken handles from the gauge case remained on the back of the truck. Only the gauge and case were taken.

TX Bureau of Radiation Control, Local police, states surrounding TX, and Mexico have been notified. Texas Incident # I-8067.