Event Notification Report for September 17, 2003

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
09/16/2003 - 09/17/2003

EVENT NUMBERS
401654016640180

!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 40165
Facility: FT CALHOUN
Region: 4     State: NE
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: RANDALL CADE
HQ OPS Officer: STEVE SANDIN
Notification Date: 09/17/2003
Notification Time: 10:29 [ET]
Event Date: 09/17/2003
Event Time: 08:43 [CDT]
Last Update Date: 09/19/2003
Emergency Class: ALERT
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
Person (Organization):
ANTHONY GODY (R4)
DAVID SKEEN (NRR)
RICHARD WESSMAN (IRO)
KEN SWEETSER (FEMA)
STUART BAILEY (DOE)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
POST ALERT EMERGENCY DECLARATION BASED ON CALCULATED RCS INVENTORY LOSS

"The plant is currently in Mode 5 for a Refueling outage. Reactor Coolant System (RCS) level was being maintained just below the Reactor Vessel flange, 1012.33 feet, with Shutdown Cooling in service and Shutdown Cooling Purification in service. RCS temperature was 100F. At 0821 a lowering level was noted on the Control Room level indications LI-119 and LI-197. At 0824 Shutdown Cooling Purification was secured and the lowering level was stopped with an indicated RCS level 1010.33 feet. At 0843 it was determined that approximately 1350 gallons of RCS water was lost over the 3 minutes that the event lasted. It was determined that during that time conditions existed to enter EAL 1.4, RCS leak greater than 40 gpm. At no time was Shutdown Cooling lost and RCS temperature remained at 100F. At 0825 Abnormal Operating Procedure (AOP-19) was entered. Makeup to the RCS was initiated immediately and level was completely restored at 0842 with charging pumps secured. It has not been determined at this time where the inventory went. A walkdown of the Containment and Auxiliary Building has been completed.

"At this time the plant is stable with an RCS level on 1012.5 feet."

The licensee is conducting an investigation and will provide an update to this report. The licensee informed both the State of NE and IA and the NRC Resident Inspector.

* * * UPDATE AT 1109 EDTR ON 09/19/03 FROM ERICK MATZKE TO S. SANDIN * * *

The licensee is retracting this report based on the following:

"On September 17, 2003, the Fort Calhoun Station notified the NRC that conditions had existed, for about 3 minutes, to make an alert notification. No alert was declared as the time the station was in the condition was such, a limited time. The condition that required the notification was a reactor coolant system (RCS) leak of >40 GPM. The event occurred as follows:

"At approximately 0821 on September 17, 2003, Operations noted decreasing level in the reactor vessel. This was indicated on both of the shutdown RCS level indicators. Due to the uncontrolled (indicated) reduction in RCS level, AOP-19 was entered. Within minutes, the indicated level had dropped from 1012' 6" to 1010' 3". Shutdown cooling purification was isolated. The two (2) charging pumps running for shutdown purification were left in operation. After a few minutes, the charging pump's 80 gpm flow caused the RCS level to stop dropping and RCS level began to rise. During and immediately following this event, numerous walkdowns of containment and the auxiliary building were performed that ensured there was no loss of water from the RCS. No coolant leakage was noted during the walkdowns.

"The cause of the level change was small pressure in the head making the indication read higher than actual. Disconnecting the HJTC clamp allowed a positive vent which caused indicated level to fall. When interviewing the craft performing the work on the HJTC, it was noted that when removing the clamp front a HJTC, the craft noticed a small amount of water bubbling on the HJTC and when an attempt was made to lift the HJTC hub, air was heard in the vicinity of the HJTC. Additionally the craft stated there was some resistance felt from the HTJC when attempting removal. The craft then contacted radiation protection to determine what personnel protection was required. On the second attempt to lift the hub, the craft heard air flow in the vicinity again. When the clamp was finally lifted there was little resistance. It is suspected that the air at the HJTC was due to a pressure differential between the vessel and the containment atmosphere. The higher pressure in the reactor vessel caused level indications to read higher than actual level by approximately 2 feet. When the HJTC flange opened, the change in pressure caused a redistribution of water levels in the RCS. This caused the indicated RCS level change.

"There was never a leak of RCS coolant outside of the RCS. Therefore, this event notification is being retracted."

The licensee informed the NRC Resident Inspector. Notified R4DO(Gody).


Power Reactor
Event Number: 40166
Facility: INDIAN POINT
Region: 1     State: NY
Unit: [2] [] []
RX Type: [2] W-4-LP,[3] W-4-LP
NRC Notified By: PHIL SANTINI
HQ OPS Officer: NATHAN SANFILIPPO
Notification Date: 09/17/2003
Notification Time: 17:44 [ET]
Event Date: 09/17/2003
Event Time: 17:35 [EDT]
Last Update Date: 09/17/2003
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
HAROLD GRAY (R1)
JOSE CALVO (NRR)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
HURRICANE FORCE WINDS WITHIN 500 NAUTICAL MILES OF PLANT

The Indian Point Unit 2 Technical Specification 3.14.A requires prompt notification of the NRC when hurricane force winds are within 500 nautical miles of the plant. Indian Point will continue to monitor the situation and update as necessary.

The licensee has notified the NRC Resident Inspector.


General Information or Other
Event Number: 40180
Rep Org: ARIZONA RADIATION REGULATORY AGENCY
Licensee: ARIZONA ONCOLOGY SERVICES
Region: 4
City: SCOTTSDALE   State: AZ
County:
License #: AZ-07-161
Agreement: Y
Docket:
NRC Notified By: AUBREY V. GODWIN
HQ OPS Officer: ERIC THOMAS
Notification Date: 09/19/2003
Notification Time: 13:00 [ET]
Event Date: 09/17/2003
Event Time: 13:00 [MST]
Last Update Date: 09/19/2003
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
ANTHONY GODY (R4)
C.W. (BILL) REAMER (NMSS)
Event Text
AGREEMENT STATE REPORT - MEDICAL EVENT

"At approximately 1:00 PM September 17, 2003 the Agency was informed of a medical event. The reporting individual indicated that in the course of treating a breast cancer, a saline filled balloon was used to aid in positioning the HDR source, Iridium 192, approximately 9.589 curies. Starting September 15, 2003, a series of 10 fractional treatments was prescribed. Between each, an ultra sound image was made to assure the continued proper placement of the source. The ultra sound technician indicated all was ok for all treatments. After the series was completed, the balloon was deflated for removal and the physician then noted that the balloon had ruptured. A review of the retained ultra sound images indicated [that] starting with treatment 7 the balloon was deflated. The doses were recalculated and the tissue dose was 40 [percent] higher than prescribed. The adjacent skin dose was calculated to be 266 cGy [centigray] rather than the 175 cGy [centigray] as originally calculated. The licensee has proposed corrective measures to prevent a recurrence of this event. The balloon manufacturer has been informed of this event.

"The patient has been informed of the event. The medical review indicates some additional fat necrosis and possible inflammation may occur. It will be reviewed as a part of the patient follow up."