Skip to main content

Event Notification Report for February 04, 2003

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
02/03/2003 - 02/04/2003

EVENT NUMBERS
395593956039561

Power Reactor
Event Number: 39559
Facility: CATAWBA
Region: 2     State: SC
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: JIMMY BURGESS
HQ OPS Officer: YAMIR DIAZ
Notification Date: 02/04/2003
Notification Time: 11:24 [ET]
Event Date: 02/04/2003
Event Time: 09:58 [EST]
Last Update Date: 02/04/2003
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
JOEL MUNDY (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 A/R Y 100 Power Operation 0 Hot Standby
Event Text
REACTOR TRIP CAUSE BY A HI-HI LEVEL CONDITION IN STEAM GENERATOR

"While replacing a feedwater transmitter, digital feedwater control for CFPT (condensate feedwater pump turbines) and all 4 S/G (steam generators) went to manual. The corresponding feedwater swing caused a Hi-Hi level condition in 1B S/G which resulted in a turbine trip, subsequent reactor trip and auxiliary feedwater auto start. All systems functioned normally." All rods fully inserted and auxiliary feedwater pumps operated properly.

The licensee notified the NRC resident inspector.


Power Reactor
Event Number: 39560
Facility: BRUNSWICK
Region: 2     State: NC
Unit: [1] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: MARK TURKAL
HQ OPS Officer: MIKE RIPLEY
Notification Date: 02/04/2003
Notification Time: 16:05 [ET]
Event Date: 02/04/2003
Event Time: 14:34 [EST]
Last Update Date: 02/04/2003
Emergency Class: NON EMERGENCY
10 CFR Section:
26.73 - FITNESS FOR DUTY
Person (Organization):
JOEL MUNDY (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 94 Power Operation 94 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
FITNESS FOR DUTY

"A licensed operator tested positive for a controlled substance as a result of a random test. The employee's access to the protected area has been terminated. The employee has requested split sample testing. The NRC Resident Inspector has been notified."


Power Reactor
Event Number: 39561
Facility: HOPE CREEK
Region: 1     State: NJ
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: ART BREADY
HQ OPS Officer: GERRY WAIG
Notification Date: 02/05/2003
Notification Time: 00:12 [ET]
Event Date: 02/04/2003
Event Time: 22:40 [EST]
Last Update Date: 02/05/2003
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
JAMES NOGGLE (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
LOSS OF METEOROLOGICAL DATA AT SALEM AND HOPE CREEK STATIONS

"THIS 8-HOUR NOTIFICATION IS BEING MADE TO REPORT THAT THE SALEM AND HOPE CREEK SITE LOST ALL METEOROLOGICAL DATA FOR WIND SPEED, DIRECTION AND TEMPERATURE AT 1440 ON 2/04/03. ALL THREE UNITS ARE OPERATING AT 100% POWER. NO ACTUATIONS HAVE TAKEN PLACE RELATED TO THIS EVENT. THE CAUSE OF THIS LOSS IS BEING INVESTIGATED. PROCEDURAL GUIDANCE IS AVAILABLE TO OBTAIN THE NECESSARY DATA FROM THE NATIONAL WEATHER SERVICE SHOULD THIS DATA BE NECESSARY."

The licensee will notify the NRC Resident Inspector.