Event Text
TROXLER MOISTURE DENSITY GAUGE DAMAGED

During a paving job on SR2032 near Pittston, PA, a Troxler Moisture Density Gauge, Model # 3430, was run over by a roller. The area around the damaged Troxler gauge was cordoned off and the Radiation Safety Officer is driving from Hazleton to Pittston to determine the amount of damage to the Troxler gauge. The gauge contains 10 millicuries of Cesium-137 and 40 millicuries of Am-241/Be.


Power Reactor
Event Number: 39109
Facility: MILLSTONE
Region: 1     State: CT
Unit: [] [2] []
RX Type: [1] GE-3,[2] CE,[3] W-4-LP
NRC Notified By: KOSHMERL
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 08/03/2002
Notification Time: 12:40 [ET]
Event Date: 08/03/2002
Event Time: 11:42 [EDT]
Last Update Date: 08/03/2002
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - PLANT S/D REQD BY TS
Person (Organization):
J. BRADLEY FEWELL (R1)
DAVID MATTHEWS (NRR)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 99 Power Operation
Event Text
PLANT ENTERED A REQUIRED TECHNICAL SPECIFICATION SHUTDOWN DUE TO RCS LEAKAGE

The licensee detected a through wall leak on the charging system header discharge that is <0.1gpm. They have declared the ECCS inoperable, but available. Plant entered TS 3.0.3 and will be in cold shutdown within 30 hours. At this RCS leakage rate they have not exceeded any TS limits. The reason for the leakage has not yet been determined.


The NRC Resident Inspector, State and local agencies have been notified. There will be a press release.