Skip to main content

Event Notification Report for May 02, 2002

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
05/01/2002 - 05/02/2002

EVENT NUMBERS
3889838893

Power Reactor
Event Number: 38898
Facility: FERMI
Region: 3     State: MI
Unit: [2] [] []
RX Type: [2] GE-4
NRC Notified By: KEVIN DAHM
HQ OPS Officer: MIKE NORRIS
Notification Date: 05/03/2002
Notification Time: 17:33 [ET]
Event Date: 05/02/2002
Event Time: 18:34 [EDT]
Last Update Date: 05/03/2002
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
BRENT CLAYTON (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
ABILITY TO MEET 10 CFR 50 APPENDIX R III.G.3 NOT ANALYZED

"Operating License Condition 2.C(9) - Modification for Fire Protection ( Section 9.5.1 SSER #5 and SSER #6)

"On May 2, 2002 at 1834 hours, during a Fire Protection Self-Assessment field walk down of procedure 20.000.18, 'Shutdown From Outside The Control Room', a procedure step was identified that could not be performed as written. Valve N2000F636, 'Condenser Hotwell Emergency Makeup Bypass Valve' could not be manually operated without the use of a ladder. No ladders were staged for this purpose, and the requirement for a ladder was not specified in the procedure. The time required to procure a ladder and perform the required operation has not been analyzed for impact on the ability to meet safe shutdown requirements of 10CFR50 Appendix R III.G.3.

"The condition was documented in the corrective action program and a ladder has been staged at the valve. This condition is being reported as a potential non conformance with Operating License Condition 2.C(9)."

The NRC Resident Inspector has been notified.


Other Nuclear Material
Event Number: 38893
Rep Org: MAXIM TECHNOLOGIES INCORPORATED
Licensee: MAXIM TECHNOLOGY INCORPORATED
Region: 3
City: INDEPENDENCE   State: MO
County:
License #: 22-C-250-01
Agreement: N
Docket:
NRC Notified By: DUSTIN BINGHAM
HQ OPS Officer: RICH LAURA
Notification Date: 05/02/2002
Notification Time: 22:00 [ET]
Event Date: 05/02/2002
Event Time: 00:00 [CDT]
Last Update Date: 05/02/2002
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
BRENT CLAYTON (R3)
ERIC LEEDS (NMSS)
Event Text
STOLEN TROXLER DENSITY GAUGE

The licensee reported a stolen troxler density gauge which was secured in the rear of a work truck located in Independence, Missouri. The licensee reported the theft to the Independence Police Department. The gauge was model number 3340 with a serial number of 22323. The isotopes and activities used in the gauge are 8.0 millicuries of CS-137 and 40 millicuries of AM-241.