Skip to main content

Event Notification Report for March 21, 2002

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
03/20/2002 - 03/21/2002

EVENT NUMBERS
38791

Power Reactor
Event Number: 38791
Facility: NINE MILE POINT
Region: 1     State: NY
Unit: [] [2] []
RX Type: [1] GE-2,[2] GE-5
NRC Notified By: GREG PITTS
HQ OPS Officer: RICH LAURA
Notification Date: 03/21/2002
Notification Time: 10:11 [ET]
Event Date: 03/21/2002
Event Time: 03:13 [EST]
Last Update Date: 03/21/2002
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
RICHARD CONTE (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 A/R N 0 Refueling 0 Refueling
Event Text
RPS LOGIC ACTUATION WHILE SHUTDOWN

"At 0315 on March 21, 2002, during Refueling at Nine Mile Point Unit 2, an actuation of the Reactor Protection System (RPS) logic occurred when air was lost to the scram air header.

"The RPS logic actuation was caused by high water level in the Scram Discharge Volume (SDV) as a result of loss of motive air to control rod scram valves. The loss of air was experienced as a result of incorrectly written procedure step sequence while securing the plants Instrument Air system.

"This event is reportable under 10CFR50.72 (b)(3)(iv)(A), Any event or condition that results in valid actuation of the Reactor Protection System (RPS)."

The NRC Resident Inspector was notified.