Skip to main content

Event Notification Report for December 26, 2001

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
12/25/2001 - 12/26/2001

EVENT NUMBERS
385933859438595

Power Reactor
Event Number: 38593
Facility: INDIAN POINT
Region: 1     State: NY
Unit: [2] [] []
RX Type: [2] W-4-LP,[3] W-4-LP
NRC Notified By: RUH
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 12/26/2001
Notification Time: 08:52 [ET]
Event Date: 12/26/2001
Event Time: 07:20 [EST]
Last Update Date: 12/26/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
MICHELE EVANS (R1)
VICTOR DRICKS (PAO)
JOSEPH HOLONICH (IRO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 A/R Y 100 Power Operation 0 Hot Shutdown
Event Text
REACTOR TRIP FROM 100% POWER DUE TO TURBINE TRIP

The plant had an auto stop oil pressure trip on the main turbine followed by a reactor trip from 100% power. The plant went into natural circulation for 1 hour at which time the #24 reactor coolant pump was put in service. Auxiliary feedwater was placed in service. Partial offsite power was lost and the three EDG's auto started and powered buses "2A" and "3A". The cause of the trip is being investigated. All rods fully inserted, no ECCS was initiated and no safety relief valves lifted, however, the atmospheric dump valves were opened to vent steam from the system. The plant is stable and in hot shutdown.

The NRC Resident Inspector was notified.


General Information or Other
Event Number: 38594
Rep Org: CBC ENGINEERS AND ASSOCIATES
Licensee: CBC ENGINEERS AND ASSOCIATES
Region: 2
City: WHITESVILLE   State: WV
County:
License #: 34-26768-02
Agreement: N
Docket:
NRC Notified By: BANNER
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 12/26/2001
Notification Time: 11:52 [ET]
Event Date: 12/26/2001
Event Time: 00:00 [EST]
Last Update Date: 12/26/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
ANNE BOLAND (R2)
BRENT CLAYTON (R3)
FRED BROWN (NMSS)
Event Text
TROXLER GAUGE STOLEN FROM CBC ENGINEERS AND ASSOCIATES OF DAYTON, OHIO

A Troxler gauge model #3430 serial # 29017 which was locked in a truck was stolen along with the truck from the driver's residence in Whitesville, West Virginia. The gauge contained 8 mCi of Cs-137 and 40 mCi of Am-241/Be. The W Va State Police were notified and the licensee will contact the local fire department along with the media to offer a reward.

* * * UPDATE ON 12/26/01 @ 1237 BY BANNER TO GOULD * * *

The vehicle was found in West Virginia with Troxler gauge intact.

Notified Reg 2 (Boland), Reg 3 (Clayton) and NMSS (Brown)


Power Reactor
Event Number: 38595
Facility: WATTS BAR
Region: 2     State: TN
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: JIM SETLIFFE
HQ OPS Officer: JOHN MacKINNON
Notification Date: 12/26/2001
Notification Time: 14:10 [ET]
Event Date: 12/26/2001
Event Time: 10:16 [EST]
Last Update Date: 12/26/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
26.73 - FITNESS FOR DUTY
Person (Organization):
ANNE BOLAND (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
PLANT EMPLOYEE TESTED POSITIVE FOR ILLEGAL DRUGS

An electrical licensee tested positive for marijuana during a random drug test. The employee's access to the plant has been pulled and his past work is being reviewed.

Call the Headquarters Operation Officer for further details.

The NRC resident inspector was notified of this event by the licensee.