Event Notification Report for October 30, 2001
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
10/29/2001 - 10/30/2001
EVENT NUMBERS
3844138444384453844638447
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 38441
Facility: SEQUOYAH
Region: 2 State: TN
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: ALLEY/HARRIS
HQ OPS Officer: JOHN MacKINNON
Region: 2 State: TN
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: ALLEY/HARRIS
HQ OPS Officer: JOHN MacKINNON
Notification Date: 10/30/2001
Notification Time: 09:30 [ET]
Event Date: 10/30/2001
Event Time: 08:50 [EST]
Last Update Date: 10/31/2001
Notification Time: 09:30 [ET]
Event Date: 10/30/2001
Event Time: 08:50 [EST]
Last Update Date: 10/31/2001
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
Person (Organization):
R2 IRC TEAM MANAGER (R2)
JOHN TAPPERT (NRR)
RENE ZAPATA (FEMA)
R2 IRC TEAM MANAGER (R2)
JOHN TAPPERT (NRR)
RENE ZAPATA (FEMA)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Refueling Shutdown | 0 | Refueling Shutdown |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
UNUSUAL EVENT DECLARED DUE TO AN UNPLANNED RADIOLOGICAL RELEASE, EMERGENCY ACTION LEVEL 7.2 (LIQUID EFFLUENT).
"At 0850 on 10/30/2001 a Notification of Unusual Event (NOUE) was declared and terminated at 0910 on 10/30/2001 at Sequoyah Nuclear Plant due to an unplanned radiological release. At 0640 on 10/30/2001 count rate on 0-RM-90-212, the Station Discharge Rad Monitor, reached the alarm setpoint of 600 CPM. An initial Chem Lab sample taken at 0720 indicated no abnormal activity. A followup sample completed at 0802 confirmed activity in the Turbine Building Sump. The Chem Lab samples confirmed the validity of this alarm and the REP declaration requirements were met. At 0810 the release was terminated by isolating the station sump and realigning to the Low Volume Waste Treatment Pond. Readings on 0-RM-90-212 are slowly trending up at present 39000 CPM. Investigation is in progress to determine and correct the source. Detailed sample analysis are also in progress to identify the magnitude and nuclides involved in this release. Followup information will be provided when available." State and Local officials were notified of this event by the licensee.
The NRC Resident Inspector was notified of this event by the licensee.
* * * UPDATE 1627EST ON 10/31/01 FROM CALVIN FIELDS TO S. SANDIN * * *
The licensee is retracting this report based on the following:
"This is an update to the October 30, 2001, notification. Subsequent analysis show that the total activity in the TB Sump was less than 35% of the ODCM limit. No release limits were exceeded and, therefore, the NOUE criteria of 2 times the ODCM limits did not exist. In accordance with NUREG-1022, Rev. 2, Section 2.8, TVA is retracting the previous notification via this follow-up telephone call."
The licensee informed the NRC Resident Inspector and will inform both state and local agencies. Notified R2IRC.
"At 0850 on 10/30/2001 a Notification of Unusual Event (NOUE) was declared and terminated at 0910 on 10/30/2001 at Sequoyah Nuclear Plant due to an unplanned radiological release. At 0640 on 10/30/2001 count rate on 0-RM-90-212, the Station Discharge Rad Monitor, reached the alarm setpoint of 600 CPM. An initial Chem Lab sample taken at 0720 indicated no abnormal activity. A followup sample completed at 0802 confirmed activity in the Turbine Building Sump. The Chem Lab samples confirmed the validity of this alarm and the REP declaration requirements were met. At 0810 the release was terminated by isolating the station sump and realigning to the Low Volume Waste Treatment Pond. Readings on 0-RM-90-212 are slowly trending up at present 39000 CPM. Investigation is in progress to determine and correct the source. Detailed sample analysis are also in progress to identify the magnitude and nuclides involved in this release. Followup information will be provided when available." State and Local officials were notified of this event by the licensee.
The NRC Resident Inspector was notified of this event by the licensee.
* * * UPDATE 1627EST ON 10/31/01 FROM CALVIN FIELDS TO S. SANDIN * * *
The licensee is retracting this report based on the following:
"This is an update to the October 30, 2001, notification. Subsequent analysis show that the total activity in the TB Sump was less than 35% of the ODCM limit. No release limits were exceeded and, therefore, the NOUE criteria of 2 times the ODCM limits did not exist. In accordance with NUREG-1022, Rev. 2, Section 2.8, TVA is retracting the previous notification via this follow-up telephone call."
The licensee informed the NRC Resident Inspector and will inform both state and local agencies. Notified R2IRC.
Power Reactor
Event Number: 38444
Facility: VERMONT YANKEE
Region: 1 State: VT
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: DAVID HALLONQUIST
HQ OPS Officer: JOHN MacKINNON
Region: 1 State: VT
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: DAVID HALLONQUIST
HQ OPS Officer: JOHN MacKINNON
Notification Date: 10/30/2001
Notification Time: 16:10 [ET]
Event Date: 10/30/2001
Event Time: 13:15 [EST]
Last Update Date: 10/30/2001
Notification Time: 16:10 [ET]
Event Date: 10/30/2001
Event Time: 13:15 [EST]
Last Update Date: 10/30/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - DEG/UNANALYZED COND 50.72(b)(3)(v)(C) - POT UNCNTRL RAD REL
10 CFR Section:
50.72(b)(2)(i) - DEG/UNANALYZED COND 50.72(b)(3)(v)(C) - POT UNCNTRL RAD REL
Person (Organization):
R1 IRC TEAM MANAGER (R1)
R1 IRC TEAM MANAGER (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
LOSS OF CONTAINMENT INTEGRITY
It has been determined that a loss of containment occurred on 10/25/01 when a tube broke on the discharge of the "B" Hydrogen/Oxygen Monitor sample pump. The monitor was secured and isolated within 25 minutes of the break. Engineering review has determined that under accident conditions, leakage from this break would have exceeded allowable containment leakage limits.
The NRC Resident Inspector was notified of this event by the licensee.
It has been determined that a loss of containment occurred on 10/25/01 when a tube broke on the discharge of the "B" Hydrogen/Oxygen Monitor sample pump. The monitor was secured and isolated within 25 minutes of the break. Engineering review has determined that under accident conditions, leakage from this break would have exceeded allowable containment leakage limits.
The NRC Resident Inspector was notified of this event by the licensee.
Power Reactor
Event Number: 38445
Facility: PALO VERDE
Region: 4 State: AZ
Unit: [1] [2] [3]
RX Type: [1] CE,[2] CE,[3] CE
NRC Notified By: DAN MARKS
HQ OPS Officer: BOB STRANSKY
Region: 4 State: AZ
Unit: [1] [2] [3]
RX Type: [1] CE,[2] CE,[3] CE
NRC Notified By: DAN MARKS
HQ OPS Officer: BOB STRANSKY
Notification Date: 10/30/2001
Notification Time: 18:56 [ET]
Event Date: 10/30/2001
Event Time: 15:30 [MST]
Last Update Date: 10/30/2001
Notification Time: 18:56 [ET]
Event Date: 10/30/2001
Event Time: 15:30 [MST]
Last Update Date: 10/30/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
IRC (R4)
IRC (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | N | 0 | Cold Shutdown | 0 | Cold Shutdown |
| 3 | N | N | 0 | Cold Shutdown | 0 | Cold Shutdown |
STATE ISSUES PRESS RELEASE REGARDING NATIONAL GUARD DEPLOYMENT
"The Governor's Office of the State of Arizona issued the attached press release regarding National Guard
deployment at the Palo Verde Nuclear Generating Station (PVNGS). The press release was issued at 15:30 MST. The Palo Verde Nuclear Generating Station has no plans to issue a press release at this time.
"The NRC Resident Inspector has been notified of the State press release and provided a copy."
"The Governor's Office of the State of Arizona issued the attached press release regarding National Guard
deployment at the Palo Verde Nuclear Generating Station (PVNGS). The press release was issued at 15:30 MST. The Palo Verde Nuclear Generating Station has no plans to issue a press release at this time.
"The NRC Resident Inspector has been notified of the State press release and provided a copy."
Power Reactor
Event Number: 38446
Facility: DUANE ARNOLD
Region: 3 State: IA
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: KOTTENSTETTE
HQ OPS Officer: BOB STRANSKY
Region: 3 State: IA
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: KOTTENSTETTE
HQ OPS Officer: BOB STRANSKY
Notification Date: 10/30/2001
Notification Time: 22:30 [ET]
Event Date: 10/30/2001
Event Time: 18:20 [CST]
Last Update Date: 10/30/2001
Notification Time: 22:30 [ET]
Event Date: 10/30/2001
Event Time: 18:20 [CST]
Last Update Date: 10/30/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
ROGER LANKSBURY (R3)
ROGER LANKSBURY (R3)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
HPCI DECLARED INOPERABLE
"On 10/30/2001 with DAEC operating in Mode 1 at 100% power, the plant was in the following LCOs for preplanned maintenance on the 'A' Loop of RHR and RHRSW subsystems: Day 1 of 7 for the LPCI system; Day 1 of 7 for the 'A' Loop of RHRSW; Day 1 of 7 for the 'A' Loop of Torus Cooling; Day 1 of 30 for the 'A' Loop of Drywell Sprays; Day 1 of 30 for the 'A' Loop of Torus Sprays.
"At 1820, the HPCI system was declared inoperable due to a Oil leak on the HPCI oil system. A 14 day, 7 day, and 72 hour LCOs were entered per Technical Specifications conditions 3.5.1.F, 3.5.1.G and 3.5.1.H.
"The unplanned HPCI system inoperability is reportable under 50.72(b)(3)(v)(D) and 50.73(a)(2)(v)(D) as a failure of a single train of equipment required to mitigate the consequence of an accident.
"On 10/29/2001, system engineering personnel discovered a small oil leak on the HPCI oil system. During work planning walkdowns with maintenance personnel on 10/30/2001, the leak located under insulation lagging on the 38 psig portion of the HPCI oil system at 3/4" swagelock fitting was determined to be 90 drops per minute. HPCI was declared inoperable at 1820 on 10/30/2001. Maintenance is in progress to repair the 3/4" fitting.
"The DAEC PSA computer model Sentinel was used to determine the risk significance of having the 'A' RHR, 'A' RHRSW and HPCI systems inoperable at the same time. The initial CDF for having the 'A' Loop of RHR and RHRSW inoperable was 1.602E-5. With the HPCI, RHR and RHRSW systems inoperable, the CDF value was determined to increase to 2.390E-5 which would still be considered a green status."
The NRC resident inspector has been informed of this event by the licensee.
"On 10/30/2001 with DAEC operating in Mode 1 at 100% power, the plant was in the following LCOs for preplanned maintenance on the 'A' Loop of RHR and RHRSW subsystems: Day 1 of 7 for the LPCI system; Day 1 of 7 for the 'A' Loop of RHRSW; Day 1 of 7 for the 'A' Loop of Torus Cooling; Day 1 of 30 for the 'A' Loop of Drywell Sprays; Day 1 of 30 for the 'A' Loop of Torus Sprays.
"At 1820, the HPCI system was declared inoperable due to a Oil leak on the HPCI oil system. A 14 day, 7 day, and 72 hour LCOs were entered per Technical Specifications conditions 3.5.1.F, 3.5.1.G and 3.5.1.H.
"The unplanned HPCI system inoperability is reportable under 50.72(b)(3)(v)(D) and 50.73(a)(2)(v)(D) as a failure of a single train of equipment required to mitigate the consequence of an accident.
"On 10/29/2001, system engineering personnel discovered a small oil leak on the HPCI oil system. During work planning walkdowns with maintenance personnel on 10/30/2001, the leak located under insulation lagging on the 38 psig portion of the HPCI oil system at 3/4" swagelock fitting was determined to be 90 drops per minute. HPCI was declared inoperable at 1820 on 10/30/2001. Maintenance is in progress to repair the 3/4" fitting.
"The DAEC PSA computer model Sentinel was used to determine the risk significance of having the 'A' RHR, 'A' RHRSW and HPCI systems inoperable at the same time. The initial CDF for having the 'A' Loop of RHR and RHRSW inoperable was 1.602E-5. With the HPCI, RHR and RHRSW systems inoperable, the CDF value was determined to increase to 2.390E-5 which would still be considered a green status."
The NRC resident inspector has been informed of this event by the licensee.
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 38447
Facility: FERMI
Region: 3 State: MI
Unit: [2] [] []
RX Type: [2] GE-4
NRC Notified By: D. COSEO
HQ OPS Officer: BOB STRANSKY
Region: 3 State: MI
Unit: [2] [] []
RX Type: [2] GE-4
NRC Notified By: D. COSEO
HQ OPS Officer: BOB STRANSKY
Notification Date: 10/31/2001
Notification Time: 14:55 [ET]
Event Date: 10/30/2001
Event Time: 19:00 [EST]
Last Update Date: 11/23/2001
Notification Time: 14:55 [ET]
Event Date: 10/30/2001
Event Time: 19:00 [EST]
Last Update Date: 11/23/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
ROGER LANKSBURY (R3)
ROGER LANKSBURY (R3)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | N | 0 | Refueling | 0 | Refueling |
24-HOUR REPORT DUE TO VIOLATION OF LICENSE CONDITION
"On 10/30/2001 at 1900 hours, during a walkdown of approximately 600 fire barrier penetrations which had been mistakenly excluded from the Fermi 2 fire barrier penetration seal inspection program, 11 penetrations were found to have no seal material installed. To date, over 350 of the approximately 600 fire barrier penetrations not included in the program have been inspected. The lack of seal material in these penetrations constitutes an inoperable 10 CFR 50, Appendix R fire rated barrier and is reportable under License Condition 2.F as a violation of License Condition 2.C (9), 'Modifications for Fire Protection.' The plant is currently shut down for refueling. Hourly fire watches have been established in the affected areas as required by the Technical Requirements Manual. Detroit Edison will report any further missing seals that are identified as part of this inspection."
The NRC resident inspector has been informed of this report by the licensee.
* * * UPDATE 11/23/01 AT 1805EST FROM KEVIN DAHM TO S. SANDIN * * *
The licensee is retracting this report based on the following:
"The 600 (approximately) fire barrier penetration seals which had been mistakenly excluded from the Fermi 2 fire barrier penetration seal inspection program have now all been inspected. Fifteen (15) of these penetrations were found to have not been sealed. These 15 penetrations are all in the same fire barrier. This fire barrier has been evaluated in accordance with Generic Letter 86-10, and it has been determined that the as found configuration is adequate to ensure the capability to achieve and maintain safe shutdown in the event of a fire. Therefore, this condition does not constitute a violation of License Condition 2.C.(9) and is not reportable."
The licensee informed the NRC Resident Inspector. Notified R3DO(Lipa).
"On 10/30/2001 at 1900 hours, during a walkdown of approximately 600 fire barrier penetrations which had been mistakenly excluded from the Fermi 2 fire barrier penetration seal inspection program, 11 penetrations were found to have no seal material installed. To date, over 350 of the approximately 600 fire barrier penetrations not included in the program have been inspected. The lack of seal material in these penetrations constitutes an inoperable 10 CFR 50, Appendix R fire rated barrier and is reportable under License Condition 2.F as a violation of License Condition 2.C (9), 'Modifications for Fire Protection.' The plant is currently shut down for refueling. Hourly fire watches have been established in the affected areas as required by the Technical Requirements Manual. Detroit Edison will report any further missing seals that are identified as part of this inspection."
The NRC resident inspector has been informed of this report by the licensee.
* * * UPDATE 11/23/01 AT 1805EST FROM KEVIN DAHM TO S. SANDIN * * *
The licensee is retracting this report based on the following:
"The 600 (approximately) fire barrier penetration seals which had been mistakenly excluded from the Fermi 2 fire barrier penetration seal inspection program have now all been inspected. Fifteen (15) of these penetrations were found to have not been sealed. These 15 penetrations are all in the same fire barrier. This fire barrier has been evaluated in accordance with Generic Letter 86-10, and it has been determined that the as found configuration is adequate to ensure the capability to achieve and maintain safe shutdown in the event of a fire. Therefore, this condition does not constitute a violation of License Condition 2.C.(9) and is not reportable."
The licensee informed the NRC Resident Inspector. Notified R3DO(Lipa).