Skip to main content

Event Notification Report for October 28, 2001

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
10/27/2001 - 10/28/2001

EVENT NUMBERS
38435

Power Reactor
Event Number: 38435
Facility: SURRY
Region: 2     State: VA
Unit: [1] [] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: ALLEN HARROW
HQ OPS Officer: LEIGH TROCINE
Notification Date: 10/28/2001
Notification Time: 01:05 [ET]
Event Date: 10/28/2001
Event Time: 00:15 [EDT]
Last Update Date: 11/02/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(ii)(A) - DEGRADED CONDITION
Person (Organization):
BOB HAAG, REGION 2 (IRC)
WILLIAM BECKNER (NRR)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Refueling 0 Refueling
Event Text
DISCOVERY OF APPARENT THROUGH-WALL INDICATIONS ON CONTROL ROD DRIVE MECHANISM PENETRATIONS

The following text is a portion of a facsimile received from the licensee:

"Following shutdown for a scheduled refueling outage, Surry Unit 1 performed a visual inspection of the reactor vessel control rod drive mechanism (CRDM) penetrations per NRC Bulletin 2001-01."

"At approximately 0015 on October 28, 2001, apparent through-wall indications were identified on CRDM penetrations 27 and 40. The inspection is not yet complete. This condition did not pose a significant safety risk during plant operation. This is being reported as a non-emergency (8-hour report in accordance with 10 CFR 50.72(b)(3)(ii)(A) and 50.73(a)(2)(ii)(A)."

The licensee stated that the unit is currently defueled.

The licensee notified the NRC resident inspector.

* * * UPDATE ON 11/2/01 @ 0338 BY HILBERT-SEMMES TO GOULD * * * UPDATE

At approximately 0220 hours on November 2, 2001, additional indications were identified as having flaws that are not acceptable under ASME Section XI IWB-3600 on penetrations 65, 47, and 69. Two previously identified indications were previously reported in this event. The inspection of all CRDM penetrations is now complete with disposition of one penetration still underway. This condition did not pose a significant safety risk during plant operation. This is being reported as an update.

The NRC Resident Inspector was notified. The Reg 2 IRC Manager was notified.

***** UPDATE FROM LISA HILBERT-SEMMES TO LEIGH TROCINE AT 2357 ON 11/02/01 *****

The following text is a portion of a facsimile received from the licensee:

"At approximately 2250 hours on November 2, 2001, an additional CRDM penetration (location number 18) was identified as having flaws that are not acceptable under ASME Section XI IWB-3600. Five previously identified penetrations were reported [...]. This condition did not pose a significant safety risk during plant operation. This is being reported as a non-emergency 8-hour report in accordance with 10 CFR 50.72(b)(3)(ii)(A) and 50.73(a)(2)(ii)(A), a condition that results in a principal safety barrier being seriously degraded."

The licensee notified the NRC resident inspector. The NRC operations officer notified the Region 2 Incident Response Center (Steve Rudisail) and NRR EO (John Zwolinski).