Skip to main content

Event Notification Report for August 09, 2001

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
08/08/2001 - 08/09/2001

EVENT NUMBERS
381943819538196

Power Reactor
Event Number: 38194
Facility: OYSTER CREEK
Region: 1     State: NJ
Unit: [1] [] []
RX Type: [1] GE-2
NRC Notified By: ERIC DeMONCH
HQ OPS Officer: LEIGH TROCINE
Notification Date: 08/09/2001
Notification Time: 18:18 [ET]
Event Date: 08/09/2001
Event Time: 16:01 [EDT]
Last Update Date: 08/09/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
DANIEL HOLODY (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 93 Power Operation
Event Text
OFFSITE NOTIFICATION REGARDING APPROVAL TO EXCEED THE NORMAL OPERATING DISCHARGE TEMPERATURE PERMIT LIMIT DUE TO THE EMERGENCY NEED FOR POWER AND CONDITIONS ON THE GRID

At approximately 1500, the licensee began to reduce reactor power from 100% because main condenser discharge temperature began to approach the discharge permit temperature limit of 106°F. At 1601, the system dispatcher notified the licensee of an emergency need for power and informed the licensee that the criteria to exceed the discharge permit temperature limit was authorized. In this condition, a discharge temperature of 110°F is allowed. As a result, the licensee ceased the power reduction with the unit at approximately 98% reactor power and returned reactor power to 100%.

The emergency need for power was cancelled at 1612. As a result, the licensee commenced another power reduction in order to reduce the main condenser discharge temperature and comply with the 106°F discharge permit limit.

The highest main condenser discharge temperature attained was 106.36°F. Reactor power is currently stable at 93%.

The licensee notified the New Jersey Department of Environmental Protection and plans to notify the NRC resident inspector.


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 38195
Facility: PALISADES
Region: 3     State: MI
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: MARK HOLBEIN
HQ OPS Officer: LEIGH TROCINE
Notification Date: 08/09/2001
Notification Time: 21:37 [ET]
Event Date: 08/09/2001
Event Time: 20:00 [EDT]
Last Update Date: 11/19/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(ii)(B) - UNANALYZED CONDITION
Person (Organization):
ANNE MARIE STONE (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
DISCOVERY THAT SUPPORTS MAY NOT BE CAPABLE OF PROPERLY RESTRAINING THE MISSILE SHIELD DURING A DESIGN BASIS SEISMIC EVENT

The following text is a portion of a facsimile received from the licensee:

"Evaluation of the Missile Shield, over the Reactor Vessel Head, has revealed that the supports for the Missile Shield may not be capable of properly restraining the Missile [Shield] in the horizontal direction during a Design Basis Seismic Event. Consequently the Missile Shield is considered inoperable pending further evaluation. This is being reported as an unanalyzed condition that could significantly degrade Plant safety."

The licensee notified the NRC resident inspector.

* * * RETRACTED AT 1602 EST ON 11/19/01 BY DAN MALONE TO FANGIE JONES * * *

The licensee is retracting this event after further evaluation determined that the supports for the Missile Shield are adequate to restrain it during a Design Basis Seismic Event. The shield has been determined to be Operable, but degraded.

The licensee notified the NRC Resident Inspector. The R3DO (Christine Lipa) has been notified.


General Information or Other
Event Number: 38196
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: TERRACON ENGINEERING
Region: 4
City: Dallas   State: TX
County:
License #: L05268
Agreement: Y
Docket:
NRC Notified By: JAMES H. OGDEN
HQ OPS Officer: JOHN MacKINNON
Notification Date: 08/10/2001
Notification Time: 09:25 [ET]
Event Date: 08/09/2001
Event Time: 00:00 [CDT]
Last Update Date: 08/10/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
CHARLES MARSCHALL (R4)
FRED BROWN (NMSS)
Event Text
STOLEN HUMBOLDT 5001C NUCLEAR GAUGE


The gauge was lost during the hours of darkness July 15-16, 2001, from the back of a truck that was parked overnight at the home of the driver. The gauge and it's transport case were removed from a parked pickup truck by cutting the chain securing the gauge to the bed of the truck. Also stolen during this incident was the operator's toolbox and assorted hand tools. The gauge is a Humboldt Model 5001C, Serial # 2606, containing two radioactive sources: 10 millicuries of cesium-137, Serial #6171GQ; and 40 millicuries of americium-241;Be, Serial # NJ02767. A police report was filed on July 16, 2001, with the Dallas Police Department (Report # 0551265-K). A press release offering a $250 reward for the return of the gauge was run in the Dallas Morning News for two days. The gauge has not been recovered as of this date. The licensee has been cited for failure to maintain the gauge under constant surveillance. The state of Texas has informed the Radiation Control authorities in Mexico, Arizona, New Mexico, Arkansas, and Louisiana, as well as the Humboldt Radiation Safety Officer.