Event Notification Report for June 25, 2001
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
06/24/2001 - 06/25/2001
EVENT NUMBERS
3809138092380933809838118
Power Reactor
Event Number: 38091
Facility: COOPER
Region: 4 State: NE
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: KENT CHRISP
HQ OPS Officer: STEVE SANDIN
Region: 4 State: NE
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: KENT CHRISP
HQ OPS Officer: STEVE SANDIN
Notification Date: 06/25/2001
Notification Time: 06:07 [ET]
Event Date: 06/25/2001
Event Time: 04:33 [CDT]
Last Update Date: 06/25/2001
Notification Time: 06:07 [ET]
Event Date: 06/25/2001
Event Time: 04:33 [CDT]
Last Update Date: 06/25/2001
Emergency Class: ALERT
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
Person (Organization):
DAVE LOVELESS (R4)
TAD MARSH (EO)
JOSEPH HOLONICH (IRO)
ELLIS MERSCHOFF (RA)
KEN BROCKMAN (R4)
DAVE LOVELESS (R4)
TAD MARSH (EO)
JOSEPH HOLONICH (IRO)
ELLIS MERSCHOFF (RA)
KEN BROCKMAN (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 60 | Power Operation |
UNUSUAL EVENT DECLARED DUE TO A FIRE IN THE PROTECTED AREA LASTING 16 MINUTES
The licensee fire brigade responded to and extinguished a small oil fire in the Startup Transformer yard after entering EAL 5.1.1. The fire burned for approximately 16 minutes. The plant has reduced power from 100% to 60%. The licensee notified state/local agencies and the NRC resident inspector. At the time of the notification, the Emergency Director had upgraded the event to the Alert declaration.
* * * UPDATE 0625EDT FROM CHRISP TO ROBERT STRANSKY * * *
At 0455CDT the licensee declared an Alert entering EAL 5.2.1 after determining that the fire has impacted an offsite power source. Unit has entered single loop operations due to the loss of the Startup Transformer. The licensee notified state/local agencies and the NRC resident inspector.
At 0619EDT, Region IV RA in consultation with the IRO Manager placed the Agency in Monitoring. Notified FEMA(Sweetzer), DOE(Yates), EPA-NRC(Terry), USDA(Graham) and HHS(Cleveland), EPA-REG(Curry).
* * * COMMISSIONERS' ASSISTANTS' BRIEFING AT 0900 6/25/2001 * * *
Briefer: K. Brockman (R IV). Participants: Wessman, Holonich (IRO), Thadani (NRR), Hayden, Dricks (OPA), Droggitis (STP), Gerke (OCA), Haag (EDO), Tschiltz (Chm. Meserve), Hiltz (Comm. Dicus), Beall (Comm. McGaffigan), Davis (Comm. Diaz), McCabe (Comm. Merrifield).
* * * UPDATE AT 1032 FROM PLETTNER TAKEN BY STRANSKY * * *
The Alert was terminated at 0908. The NRC resident inspector has been informed by the licensee.
The licensee fire brigade responded to and extinguished a small oil fire in the Startup Transformer yard after entering EAL 5.1.1. The fire burned for approximately 16 minutes. The plant has reduced power from 100% to 60%. The licensee notified state/local agencies and the NRC resident inspector. At the time of the notification, the Emergency Director had upgraded the event to the Alert declaration.
* * * UPDATE 0625EDT FROM CHRISP TO ROBERT STRANSKY * * *
At 0455CDT the licensee declared an Alert entering EAL 5.2.1 after determining that the fire has impacted an offsite power source. Unit has entered single loop operations due to the loss of the Startup Transformer. The licensee notified state/local agencies and the NRC resident inspector.
At 0619EDT, Region IV RA in consultation with the IRO Manager placed the Agency in Monitoring. Notified FEMA(Sweetzer), DOE(Yates), EPA-NRC(Terry), USDA(Graham) and HHS(Cleveland), EPA-REG(Curry).
* * * COMMISSIONERS' ASSISTANTS' BRIEFING AT 0900 6/25/2001 * * *
Briefer: K. Brockman (R IV). Participants: Wessman, Holonich (IRO), Thadani (NRR), Hayden, Dricks (OPA), Droggitis (STP), Gerke (OCA), Haag (EDO), Tschiltz (Chm. Meserve), Hiltz (Comm. Dicus), Beall (Comm. McGaffigan), Davis (Comm. Diaz), McCabe (Comm. Merrifield).
* * * UPDATE AT 1032 FROM PLETTNER TAKEN BY STRANSKY * * *
The Alert was terminated at 0908. The NRC resident inspector has been informed by the licensee.
Power Reactor
Event Number: 38092
Facility: SAINT LUCIE
Region: 2 State: FL
Unit: [1] [2] []
RX Type: [1] CE,[2] CE
NRC Notified By: HESSLING
HQ OPS Officer: CHAUNCEY GOULD
Region: 2 State: FL
Unit: [1] [2] []
RX Type: [1] CE,[2] CE
NRC Notified By: HESSLING
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 06/25/2001
Notification Time: 09:15 [ET]
Event Date: 06/25/2001
Event Time: 08:45 [EDT]
Last Update Date: 06/25/2001
Notification Time: 09:15 [ET]
Event Date: 06/25/2001
Event Time: 08:45 [EDT]
Last Update Date: 06/25/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
STEPHEN CAHILL (R2)
STEPHEN CAHILL (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
NOTIFICATION TO THE FLORIDA STATE AND WILDLIFE WAS MADE BY THE LICENSEE
This notification was made due to a sick, underweight loggerhead turtle being transported offsite for rehabilitation pursuant to 10 CFR 50.72(b)(2)(xi).
The NRC Resident Inspector and the state were notified.
This notification was made due to a sick, underweight loggerhead turtle being transported offsite for rehabilitation pursuant to 10 CFR 50.72(b)(2)(xi).
The NRC Resident Inspector and the state were notified.
Power Reactor
Event Number: 38093
Facility: SOUTH TEXAS
Region: 4 State: TX
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: GREG JANAK
HQ OPS Officer: DOUG WEAVER
Region: 4 State: TX
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: GREG JANAK
HQ OPS Officer: DOUG WEAVER
Notification Date: 06/25/2001
Notification Time: 13:59 [ET]
Event Date: 06/25/2001
Event Time: 10:00 [CDT]
Last Update Date: 06/25/2001
Notification Time: 13:59 [ET]
Event Date: 06/25/2001
Event Time: 10:00 [CDT]
Last Update Date: 06/25/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
GREG PICK (R4)
GREG PICK (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
OFFSITE NOTIFICATION OF AN EMERGENCY SIREN ACTIVATION
"An STP Emergency Notification three tone siren was activated for a grass fire near the Tres Palacios Oaks community (located with in the 10 mile Emergency planning Zone) June 24, 2001, at approximately 3:00pm. The local Fire Department used the proper designated fire alarm signal which is separate from the emergency notification signal used in an emergency event at South Texas Project.
"Local residents subsequently contacted the Matagorda County Sheriff's Office inquiring about evacuation rumors during the event. The Sheriff's Office contacted South Texas Project personnel to ensure that no emergency situation existed at the Plant.
"No formal press release is planned but due to local public interest and county obligations, the County Sheriff and County Emergency Response Director along with STP personnel notified the Matagorda County Commissioner's Court of the situation at 10:00am CDT on June 25, 2001. The local media attended this meeting."
The siren in question serves not only as an emergency notification siren for the plant but also for local emergencies such as fires. The sound emitted is different in each case. Since the fire department used the proper alarm the licensee believes the correct sound was emitted.
The licensee notified the NRC resident inspector.
"An STP Emergency Notification three tone siren was activated for a grass fire near the Tres Palacios Oaks community (located with in the 10 mile Emergency planning Zone) June 24, 2001, at approximately 3:00pm. The local Fire Department used the proper designated fire alarm signal which is separate from the emergency notification signal used in an emergency event at South Texas Project.
"Local residents subsequently contacted the Matagorda County Sheriff's Office inquiring about evacuation rumors during the event. The Sheriff's Office contacted South Texas Project personnel to ensure that no emergency situation existed at the Plant.
"No formal press release is planned but due to local public interest and county obligations, the County Sheriff and County Emergency Response Director along with STP personnel notified the Matagorda County Commissioner's Court of the situation at 10:00am CDT on June 25, 2001. The local media attended this meeting."
The siren in question serves not only as an emergency notification siren for the plant but also for local emergencies such as fires. The sound emitted is different in each case. Since the fire department used the proper alarm the licensee believes the correct sound was emitted.
The licensee notified the NRC resident inspector.
Power Reactor
Event Number: 38098
Facility: COOPER
Region: 4 State: NE
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: JOHN MYERS
HQ OPS Officer: STEVE SANDIN
Region: 4 State: NE
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: JOHN MYERS
HQ OPS Officer: STEVE SANDIN
Notification Date: 06/27/2001
Notification Time: 04:38 [ET]
Event Date: 06/25/2001
Event Time: 06:00 [CDT]
Last Update Date: 06/27/2001
Notification Time: 04:38 [ET]
Event Date: 06/25/2001
Event Time: 06:00 [CDT]
Last Update Date: 06/27/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
GREG PICK (R4)
GREG PICK (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 70 | Power Operation | 70 | Power Operation |
LOSS OF POWER TO EOF WHEN 12.5 KV FEEDER WAS DEENERGIZED DURING ALERT DECLARED ON 6/25/01
"The following is reportable under 10 CFR 50.72(b)(3)(xiii), 'Loss of Emergency Preparedness Capabilities.'
"During the ALERT declared on June 25, 2001 (Reference: EN # 38091), there was no AC power in the Emergency Operations Facility (EOF) when the 12.5 KV feeder was lost. This impacted the ability of the EOF personnel to activate the facility in a timely manner and interrupted certain EOF functions such as ventilation, normal lighting, and some AC power outlets supporting computers and other equipment.
"The facility is fully functional if the 12.5 KV feeder is available. However, if 12.5 KV power is lost, the system operating procedure limits transfer of all EOF loads to Modes 4 & 5; thus, the facility is considered conditionally functional. The procedural restrictions associated with restoration of power are being investigated.
"The Alternate EOF (AEOF) is being setup to be used in the event an emergency is declared requiring activation of the EOF if events associated with the emergency result in the loss of 12.5 KV power. EOF functions would be performed from the AEOF under such circumstances.
"This condition was determined to be reportable during the followup evaluations of this event."
The licensee will inform state/local agencies and the NRC resident inspector.
"The following is reportable under 10 CFR 50.72(b)(3)(xiii), 'Loss of Emergency Preparedness Capabilities.'
"During the ALERT declared on June 25, 2001 (Reference: EN # 38091), there was no AC power in the Emergency Operations Facility (EOF) when the 12.5 KV feeder was lost. This impacted the ability of the EOF personnel to activate the facility in a timely manner and interrupted certain EOF functions such as ventilation, normal lighting, and some AC power outlets supporting computers and other equipment.
"The facility is fully functional if the 12.5 KV feeder is available. However, if 12.5 KV power is lost, the system operating procedure limits transfer of all EOF loads to Modes 4 & 5; thus, the facility is considered conditionally functional. The procedural restrictions associated with restoration of power are being investigated.
"The Alternate EOF (AEOF) is being setup to be used in the event an emergency is declared requiring activation of the EOF if events associated with the emergency result in the loss of 12.5 KV power. EOF functions would be performed from the AEOF under such circumstances.
"This condition was determined to be reportable during the followup evaluations of this event."
The licensee will inform state/local agencies and the NRC resident inspector.
General Information or Other
Event Number: 38118
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: ALPHA TESTING INC
Region: 4
City: DALLAS State: TX
County:
License #: L03411-000
Agreement: Y
Docket:
NRC Notified By: OGDEN (by fax)
HQ OPS Officer: CHAUNCEY GOULD
Licensee: ALPHA TESTING INC
Region: 4
City: DALLAS State: TX
County:
License #: L03411-000
Agreement: Y
Docket:
NRC Notified By: OGDEN (by fax)
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 07/05/2001
Notification Time: 14:50 [ET]
Event Date: 06/25/2001
Event Time: 06:20 [CDT]
Last Update Date: 07/05/2001
Notification Time: 14:50 [ET]
Event Date: 06/25/2001
Event Time: 06:20 [CDT]
Last Update Date: 07/05/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
LINDA HOWELL (R4)
DON COOL (NMSS)
LINDA HOWELL (R4)
DON COOL (NMSS)
STOLEN HUMBOLDT HS-5001P NUCLEAR DENSITY GAUGE
A Humboldt Manufacturing Model HS-5001 P, Serial No. 30, containing 10 millicurie Cs-137, Serial No. 400SGF; and 40 millicurie Am-241/Be, Serial No. NJ00026 was stolen. Initial information indicates that the gauge was in the bed of a company pickup truck secured by bungee cords in the gauge's locked transit case when the driver stopped at a convenience store, located at 104 Kaufman Street, Rockwall, Texas. at approximately 6:15 a.m. on June 25, 2001. The operator/driver noticed the gauge was missing when he returned to his truck which was parked immediately in front of the store's front doors. He has estimated that he was in the store for approximately 5 minutes. A police report has been filed with the Rockwall, Texas Police Department. A copy of this report is currently not available. The gauge was enroute to a jobsite when stolen. The owner of the stolen gauge is a Texas Licensee, L03411-000 (Alpha Testing, Inc.. 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229).
A Humboldt Manufacturing Model HS-5001 P, Serial No. 30, containing 10 millicurie Cs-137, Serial No. 400SGF; and 40 millicurie Am-241/Be, Serial No. NJ00026 was stolen. Initial information indicates that the gauge was in the bed of a company pickup truck secured by bungee cords in the gauge's locked transit case when the driver stopped at a convenience store, located at 104 Kaufman Street, Rockwall, Texas. at approximately 6:15 a.m. on June 25, 2001. The operator/driver noticed the gauge was missing when he returned to his truck which was parked immediately in front of the store's front doors. He has estimated that he was in the store for approximately 5 minutes. A police report has been filed with the Rockwall, Texas Police Department. A copy of this report is currently not available. The gauge was enroute to a jobsite when stolen. The owner of the stolen gauge is a Texas Licensee, L03411-000 (Alpha Testing, Inc.. 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229).