Event Notification Report for May 04, 2001
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
05/03/2001 - 05/04/2001
General Information or Other
Event Number: 37965
Rep Org: NV DIV OF RAD HEALTH
Licensee: LAS VEGAS PAVING
Region: 4
City: NORTH LAS VEGAS State: NV
County:
License #: 00-11-0255-01
Agreement: Y
Docket:
NRC Notified By: STAN MARSHALL (fax)
HQ OPS Officer: LEIGH TROCINE
Licensee: LAS VEGAS PAVING
Region: 4
City: NORTH LAS VEGAS State: NV
County:
License #: 00-11-0255-01
Agreement: Y
Docket:
NRC Notified By: STAN MARSHALL (fax)
HQ OPS Officer: LEIGH TROCINE
Notification Date: 05/04/2001
Notification Time: 13:40 [ET]
Event Date: 05/04/2001
Event Time: 06:15 [PDT]
Last Update Date: 05/16/2001
Notification Time: 13:40 [ET]
Event Date: 05/04/2001
Event Time: 06:15 [PDT]
Last Update Date: 05/16/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
GAIL GOOD (R4)
FRED BROWN (NMSS)
GAIL GOOD (R4)
FRED BROWN (NMSS)
AGREEMENT STATE REPORT REGARDING A STOLEN TROXLER GAUGE
The following text is a portion of a facsimile received from the Nevada Health Division Radiological Health Section regarding a Significant Event Report:
"1. Event Report ID No. [-] NV-01-02"
"2. License No. [-] 00-11-0255-01"
"3. Licensee [-] Las Vegas Paving"
"4. Event time, date, location [-] 6:15 a.m., May 4, 2001, 7/11 Convenience Store, Losse & Cheyene Road, North Las Vegas, Nevada."
"5. Event type (e.g., misadministration, lost source, overexposure, etc.) [-] Theft of Troxler Model 4640B portable gauge."
"6. Any notifications i.e., other agencies, patient, press release, FBI, etc. [-] North Las Vegas Police Dept. notified by licensee."
"7. Event description: release, isotope, activity, exposure(s), dose, contamination level, equipment malfunction, model, serial No., etc. [-] Chain securing Troxler Model 4640B gauge to pickup bed was cut, and gauge was stolen from licensee's truck while gauge user was in [convenience] store. Gauge is a Troxler Model 4640B, s/n 1658."
"8. Transport vehicle description if known [-] Pickup truck."
"9. Media attention [-] N/A"
(Call the NRC operations officer for State contact information.)
*** UPDATE (FAX) RECEIVED AT 1228 EDT ON 05/15/09 FROM LARRY BOSCHULT TO LEIGH TROCINE ***
The following text is a portion of a facsimile received from the Nevada Health Division Radiological Health Section:
"The licensee recovered the gauge May 10, 2001. The gauge was found by a pedestrian. They saw the licensee's phone number on the gauge and called them. The licensee immediately retrieved the gauge. The lock on the gauge transport case was broken, but the gauge was still locked. The gauge has been leak tested and placed in storage pending the outcome of the leak test."
The NRC operations officer notified the R4DO (Spitzberg) and NMSS EO (Hickey).
(Call the NRC operations officer for State contact information.)
The following text is a portion of a facsimile received from the Nevada Health Division Radiological Health Section regarding a Significant Event Report:
"1. Event Report ID No. [-] NV-01-02"
"2. License No. [-] 00-11-0255-01"
"3. Licensee [-] Las Vegas Paving"
"4. Event time, date, location [-] 6:15 a.m., May 4, 2001, 7/11 Convenience Store, Losse & Cheyene Road, North Las Vegas, Nevada."
"5. Event type (e.g., misadministration, lost source, overexposure, etc.) [-] Theft of Troxler Model 4640B portable gauge."
"6. Any notifications i.e., other agencies, patient, press release, FBI, etc. [-] North Las Vegas Police Dept. notified by licensee."
"7. Event description: release, isotope, activity, exposure(s), dose, contamination level, equipment malfunction, model, serial No., etc. [-] Chain securing Troxler Model 4640B gauge to pickup bed was cut, and gauge was stolen from licensee's truck while gauge user was in [convenience] store. Gauge is a Troxler Model 4640B, s/n 1658."
"8. Transport vehicle description if known [-] Pickup truck."
"9. Media attention [-] N/A"
(Call the NRC operations officer for State contact information.)
*** UPDATE (FAX) RECEIVED AT 1228 EDT ON 05/15/09 FROM LARRY BOSCHULT TO LEIGH TROCINE ***
The following text is a portion of a facsimile received from the Nevada Health Division Radiological Health Section:
"The licensee recovered the gauge May 10, 2001. The gauge was found by a pedestrian. They saw the licensee's phone number on the gauge and called them. The licensee immediately retrieved the gauge. The lock on the gauge transport case was broken, but the gauge was still locked. The gauge has been leak tested and placed in storage pending the outcome of the leak test."
The NRC operations officer notified the R4DO (Spitzberg) and NMSS EO (Hickey).
(Call the NRC operations officer for State contact information.)
Other Nuclear Material
Event Number: 37966
Rep Org: UNIVERSITY OF PENNSYLVANIA
Licensee: UNIVERSITY OF PENNSYLVANIA
Region: 1
City: PHILADELPHIA State: PA
County: PHILADELPHIA
License #: 37-00118-07
Agreement: N
Docket:
NRC Notified By: ROBERT FORREST
HQ OPS Officer: LEIGH TROCINE
Licensee: UNIVERSITY OF PENNSYLVANIA
Region: 1
City: PHILADELPHIA State: PA
County: PHILADELPHIA
License #: 37-00118-07
Agreement: N
Docket:
NRC Notified By: ROBERT FORREST
HQ OPS Officer: LEIGH TROCINE
Notification Date: 05/05/2001
Notification Time: 11:51 [ET]
Event Date: 05/04/2001
Event Time: 16:30 [EDT]
Last Update Date: 05/07/2001
Notification Time: 11:51 [ET]
Event Date: 05/04/2001
Event Time: 16:30 [EDT]
Last Update Date: 05/07/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
35.33 - MED MISADMINISTRATION
10 CFR Section:
35.33 - MED MISADMINISTRATION
Person (Organization):
HAROLD GRAY (R1)
SUSAN FRANT (NMSS)
HAROLD GRAY (R1)
SUSAN FRANT (NMSS)
DISCOVERY OF A BRACYTHERAPY MISADMINISTRATION INVOLVING A LEAKING IODINE-125 SOURCE AT THE UNIVERSITY OF PENNSYLVANIA IN PHILADELPHIA
At approximately 1000 on 05/04/01, the licensee administered a prostate implant involving the 94 iodine-125 seeds on the order of about 1/2 millicurie per seed. (It is currently believed that the intended dosage for the patient was approximately 47 millicuries. The licensee reported that the intended dose is received from decay of the seeds which remain in the patient after treatment.)
Surveys were performed after the administration, and one of the implant needles had readings that were higher than expected. At that time, it was assumed that a source was stuck in the applicable needle (a more likely scenario). However, at approximately 1630, removable contamination (due to a leaking source) was discovered on the applicable needle. It is currently believed that one of the seeds may have been damaged during the needle loading process, and that the damaged seed was implanted into the patient during treatment administration.
At this time, there is only [one]complication that is expected as a result of the leaking iodine-125 source. It was reported that the activity from the leaking source could get into the blood stream and that the thyroid would filter the radio-iodine. Therefore, the patient may receive an unintended thyroid dose.
The authorized user was notified, and the patient was informed. The patient was also prescribed Lugols solution (a potassium iodide solution) to minimize the unintended iodine-125 thyroid uptake from the leaking seed. Initial estimates indicate a thyroid activity measurement of 73 nanocuries. [Based on normal thyroid turnover, a dose of about 320 millirem is calculated to the thyroid.]
The licensee plans to notify the referring physician.
(Call the NRC operations officer for a licensee contact telephone number.)
* * * UPDATE ON 5/7/01 @ 1059 FROM FORREST TO GOULD * * *
This update was to make the event clear. The changes appear in the brackets[ ].
Notified Reg 1 RDO(Cook) and NMSS EO(Frant)
At approximately 1000 on 05/04/01, the licensee administered a prostate implant involving the 94 iodine-125 seeds on the order of about 1/2 millicurie per seed. (It is currently believed that the intended dosage for the patient was approximately 47 millicuries. The licensee reported that the intended dose is received from decay of the seeds which remain in the patient after treatment.)
Surveys were performed after the administration, and one of the implant needles had readings that were higher than expected. At that time, it was assumed that a source was stuck in the applicable needle (a more likely scenario). However, at approximately 1630, removable contamination (due to a leaking source) was discovered on the applicable needle. It is currently believed that one of the seeds may have been damaged during the needle loading process, and that the damaged seed was implanted into the patient during treatment administration.
At this time, there is only [one]complication that is expected as a result of the leaking iodine-125 source. It was reported that the activity from the leaking source could get into the blood stream and that the thyroid would filter the radio-iodine. Therefore, the patient may receive an unintended thyroid dose.
The authorized user was notified, and the patient was informed. The patient was also prescribed Lugols solution (a potassium iodide solution) to minimize the unintended iodine-125 thyroid uptake from the leaking seed. Initial estimates indicate a thyroid activity measurement of 73 nanocuries. [Based on normal thyroid turnover, a dose of about 320 millirem is calculated to the thyroid.]
The licensee plans to notify the referring physician.
(Call the NRC operations officer for a licensee contact telephone number.)
* * * UPDATE ON 5/7/01 @ 1059 FROM FORREST TO GOULD * * *
This update was to make the event clear. The changes appear in the brackets[ ].
Notified Reg 1 RDO(Cook) and NMSS EO(Frant)