Skip to main content

Event Notification Report for April 27, 2001

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
04/26/2001 - 04/27/2001

EVENT NUMBERS
3794837949

Power Reactor
Event Number: 37948
Facility: DRESDEN
Region: 3     State: IL
Unit: [] [] [3]
RX Type: [1] GE-1,[2] GE-3,[3] GE-3
NRC Notified By: MIKE MCDONALD
HQ OPS Officer: DOUG WEAVER
Notification Date: 04/27/2001
Notification Time: 17:13 [ET]
Event Date: 04/27/2001
Event Time: 14:51 [CDT]
Last Update Date: 04/27/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL
Person (Organization):
THOMAS KOZAK (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 A/R Y 100 Power Operation 0 Hot Shutdown
Event Text
REACTOR SCRAM

UNIT 3 scrammed on low reactor water level (+8") due to flow and power oscillations from 3B reactor recirculation pump. The 3B recirculation motor generator set could not be tripped from the main control room and was tripped locally. All rods fully inserted during the scram. The unit is currently stable in mode 3. There were no ECCS injections nor did any SRVs lift.

The licensee notified the NRC resident inspector.


Other Nuclear Material
Event Number: 37949
Rep Org: MONTANA DEPT OF TRANSPORTATION
Licensee: MONTANA DEPT OF TRANSPORTATION
Region: 4
City: PLENTYWOOD   State: MT
County:
License #: 25-11498-01
Agreement: N
Docket:
NRC Notified By: REX HOY
HQ OPS Officer: DOUG WEAVER
Notification Date: 04/27/2001
Notification Time: 22:50 [ET]
Event Date: 04/27/2001
Event Time: 12:00 [MDT]
Last Update Date: 04/27/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
BILL JONES (R4)
E. WILLIAM BRACH (NMSS)
Event Text
DAMAGED TROXLER GAUGE

A Troxler moisture/density gauge model 3440 was run over on a construction site. The gauge contains 8 mCi of Cs-137 and 40 mCi of Am-241. The serial number of the gauge is 20993. The gauge was not seriously damaged. The gauge was surveyed for contaminated and none was found. The gauge has been removed from the job site and placed in storage pending further action.