Skip to main content

Event Notification Report for February 26, 2001

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
02/25/2001 - 02/26/2001

EVENT NUMBERS
3778237783

Power Reactor
Event Number: 37782
Facility: HARRIS
Region: 2     State: NC
Unit: [1] [] []
RX Type: [1] W-3-LP
NRC Notified By: MARK ELLINGTON
HQ OPS Officer: LEIGH TROCINE
Notification Date: 02/26/2001
Notification Time: 11:12 [ET]
Event Date: 02/26/2001
Event Time: 09:07 [EST]
Last Update Date: 02/26/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
BRIAN BONSER (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
OFFSITE NOTIFICATION REGARDING THE DEATH OF A PLANT EMPLOYEE

The following text is a portion of a facsimile received from the licensee:

"At 0907 this morning, the Main Control Room was informed that a plant employee had been pronounced dead by a doctor at a local hospital. The death is believed to be the result of natural causes."

"At 0636 EST, an emergency medical call was received in the Main Control Room (MCR), stating that a Harris Nuclear Plant (HNP) employee had been found unconscious at his desk in a plant office area. Offsite assistance was requested. The Site First Aid Team was dispatched and began resuscitation efforts. No pulse or respiration was present when the First Aid Team arrived. The employee was transported via ambulance to a local hospital."

"Representatives of the surrounding counties and the State of North Carolina were provided a courtesy notification regarding the request for offsite medical assistance. The NRC Senior Resident was informed."

"It is anticipated that a news release will occur as a result of the medical emergency."


Power Reactor
Event Number: 37783
Facility: PERRY
Region: 3     State: OH
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: ALAN RABENOLD
HQ OPS Officer: BOB STRANSKY
Notification Date: 02/26/2001
Notification Time: 17:31 [ET]
Event Date: 02/26/2001
Event Time: 14:26 [EST]
Last Update Date: 02/26/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION 50.72(b)(3)(xii) - OFFSITE MEDICAL
Person (Organization):
ANTON VEGEL (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Refueling 0 Refueling
Event Text
OFFSITE NOTIFICATION REGARDING CONTAMINATED INJURED INDIVIDUAL TAKEN OFFSITE

"At 1350, an injury occurred to a worker when the individual fell and injured his back. At 1426, the worker was attended by local Emergency Medical Personnel who transported the individual to our local Hospital. Initial frisking of the individual showed no contamination, but due to his back injury his back was not able to be completely monitored until arrival to the hospital. At the hospital, it was determined the individual had three small (quarter size) and very low level contaminated spots of 100 counts corrected above the background of 80 counts per minute. One spot was located in the back of the individual's head and immediately removed with water. Two additional spots were detected on the worker's pants and these were also immediately removed. The individual was further surveyed and no contamination was found. No dose was received by the individual as a result of the contamination. The decon materials and clothing was contained and returned to the plant by radiation safety supervision. The ambulance, hospital personnel and hospital materials were all surveyed and released as no contamination was detected.

"It was determined at 1555, that the individual was contaminated and per our procedures notifications will be made to the State Of Ohio and the local county Emergency Management Agencies of the incident. Due to the offsite notifications a 4 hour non-emergency call is required."

The NRC resident inspector has been informed of this event by the licensee.