Skip to main content

Event Notification Report for February 23, 2001

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
02/22/2001 - 02/23/2001

EVENT NUMBERS
3777637777377783780737796

Power Reactor
Event Number: 37776
Facility: TURKEY POINT
Region: 2     State: FL
Unit: [3] [4] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: JEFF DEAL
HQ OPS Officer: JOHN MacKINNON
Notification Date: 02/23/2001
Notification Time: 20:11 [ET]
Event Date: 02/23/2001
Event Time: 16:05 [EST]
Last Update Date: 02/23/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
BRIAN BONSER (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N Y 100 Power Operation 100 Power Operation
4 N Y 100 Power Operation 100 Power Operation
Event Text
EMERGENCY RESPONSE DATA ACQUISITION AND DISPLAY SYSTEM (ERDADS) FAILED.

At 1605 ET ERDADS CPU module overheated and failed, causing a loss of the ERDADS system. ERDADS system was returned to service at 1710 ET.

The NRC Resident Inspector will be notified by the licensee of this event.


Power Reactor
Event Number: 37777
Facility: BRUNSWICK
Region: 2     State: NC
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: BILL WOODBURY
HQ OPS Officer: DOUG WEAVER
Notification Date: 02/24/2001
Notification Time: 00:53 [ET]
Event Date: 02/23/2001
Event Time: 22:20 [EST]
Last Update Date: 02/24/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
BRIAN BONSER (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 M/R Y 37 Power Operation 0 Hot Shutdown
Event Text
MANUAL REACTOR SCRAM DURING PLANT SHUTDOWN

"On 02/23/01, at 22:20 during a planned Brunswick Unit 2 reactor shutdown for refueling a manual reactor scram was inserted. The sequence of events was as follows. At approximately 37% reactor power a turbine EHC malfunction annunciator was received and turbine bypass valves were observed opening. A turbine trip occurred on generator reverse power. A generator primary lockout signal caused the site's four emergency diesels to start. The emergency busses remained powered from offsite power, therefore the diesels did not load. With the turbine control system malfunction, a manual reactor scram was inserted. An expected reactor vessel level shrink occurred where level lowered to approximately 150" (normal vessel level is approximately 187"). This vessel level caused a group 2 and group 6 isolation signal for the respective primary containment isolation valves. These valves isolated properly."

An investigation is in progress to understand the cause of the turbine control system malfunction. Other plant systems functioned as designed.

The licensee notified the NRC resident inspector.


Power Reactor
Event Number: 37778
Facility: LIMERICK
Region: 1     State: PA
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: PETE ORPHANOS
HQ OPS Officer: DOUG WEAVER
Notification Date: 02/24/2001
Notification Time: 01:13 [ET]
Event Date: 02/23/2001
Event Time: 21:19 [EST]
Last Update Date: 02/24/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - PLANT S/D REQD BY TS 50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
GLENN MEYER (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 M/R Y 45 Power Operation 0 Hot Shutdown
Event Text
MANUAL REACTOR TRIP - SAFETY/RELIEF VALVE OPENED AT POWER

Unit 2 was manually shutdown as required by plant procedures and Technical Specifications for an actuation of a single reactor coolant system safety/relief valve. A rapid plant shutdown from critical at 85% power was performed. The shutdown required a manual actuation of the reactor protection system. All rods inserted normally on the manual scram. All plant systems operated as expected. Reactor level decreased below the low level 3 reactor protection setpoint immediately following the scram as a result of normal system response.

Current plant conditions: The reactor is in HOT SHUTDOWN at 106 psig progressing towards COLD SHUTDOWN. Reactor level is stable being controlled by condensate injection. The safety/relief valve remains open. Suppression Pool Cooling is in service with pool temperature 94 degrees Fahrenheit.

The 2N SRV was the one that opened. The licensee had been in the process of shutting down to make repairs to this valve when it fully opened. It is believed to have a faulty pilot valve.

The licensee notified the NRC resident inspector.

* * * UPDATE AT 0859 ON 2/24/01 BY RICH RECEIVED BY WEAVER * * *

The 2N reactor coolant safety/relief valve reseated at 130 psig reactor coolant pressure. The MSIVs were reopened and plant cool down continued. Unit 2 is currently in OPCON 4 with the "2B" Loop of Shutdown Cooling in service. Reactor coolant temperature is less than 200 degrees F. The licensee notified the NRC resident inspector. R1DO (Meyer) notified.


Hospital
Event Number: 37807
Rep Org: SAINT LUKE'S HOSPITAL
Licensee: SAINT LUKE'S HOSPITAL
Region: 3
City: KANSAS CITY   State: MO
County:
License #: 24-00889-01
Agreement: N
Docket:
NRC Notified By: SCOTT SORENSEN
HQ OPS Officer: JOHN MacKINNON
Notification Date: 03/05/2001
Notification Time: 15:13 [ET]
Event Date: 02/23/2001
Event Time: 11:15 [CST]
Last Update Date: 03/06/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
35.33 - MED MISADMINISTRATION
Person (Organization):
JOHN MADERA (R3)
BRIAN SMITH (NMSS)
Event Text
POSSIBLE MEDICAL MISADMINISTRATION

A remote afterloader device failed to function as it was intended during a random FDA trial. The remote afterloader was in automatic, and it was supposed to insert an intravascular, brachytherapy, 93-mCi, P-32, wire source into a patient. The remote afterloader device did not operate properly, and it inserted and withdrew the wire source 4 times. No dwell time was recorded by the afterloader since the wire source inserted less than 5 seconds each time before the wire source was automatically withdrawn. The patient was supposed to have received a total dose of 20 grays. The patient received a dose much less than intended. The FDA was notified of this event by the licensee.

***** UPDATE AT 0958 EST ON 03/06/01 FROM SCOTT SORENSEN TO LEIGH TROCINE *****

The licensee called the NRC Operation Center to clarify that the trial afterloader device was under the operator's control and that the device's internal safety checks and sensors caused the source to be removed and would not allow the dose to be delivered as intended. The following text is a portion of a clarification received from the licensee via an E-mail at 1024 EST on 03/06/01:

"Radiation therapy was not delivered as prescribed during [an] FDA-approved clinical trial for Intravascular Brachytherapy. A 93-mCi P-32 wire was to be placed across a coronary artery lesion for approximately 5
minutes of dwell time. Multiple attempts were made to place the source at the treatment position. However, an internal safety trigger in the afterloader caused the source wire to be withdrawn from the patient immediately upon source arrival at the targeted treatment site. The licensee extended the active wire a total of 4 times into the patient, followed by immediate, automatic withdrawal by the afterloader. No dwell time was recorded at the treatment location, and transit time through the patient's arteries was approximately 5 seconds each way. The procedure was abandoned without the patient receiving the intended 20 Gray dose. The event was under direct supervision of [an] NRC-approved Radiation Oncologist and the institution's Radiation Safety Officer. The FDA was notified of the study protocol deviation by the licensee."

(Call the NRC operations officer for licensee contact information.)

The NRC operations officer notified the R3DO (Madera) and NMSS EO (Sturz).


General Information or Other
Event Number: 37796
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: TERRACON
Region: 4
City: HOUSTON   State: TX
County: HARRIS
License #: L05268-001
Agreement: Y
Docket:
NRC Notified By: HELEN WATKINS (VIA FAX)
HQ OPS Officer: STEVE SANDIN
Notification Date: 03/01/2001
Notification Time: 17:00 [ET]
Event Date: 02/23/2001
Event Time: 16:45 [CST]
Last Update Date: 03/01/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
LINDA HOWELL (R4)
JOSEPH HOLONICH (NMSS)
Event Text
AGREEMENT STATE REPORT INVOLVING A STOLEN TROXLER GAUGE

2/23/01

"At approximately 4:45pm on Friday 2/23/01 a technician realized a truck with a gauge chained in the back had been stolen. The stolen gauge is a Troxler Model 3430, serial # 30170. The gauge contained two sources: 8 millicuries of Cs-137, serial # 7501851, and 40 millicuries of Am-241:Be, serial # 47-27094. [The technician] had checked the gauge our for use at a jobsite near 1960 Highway 59 in Humble, Texas. [The technician] is a trusted employee and has worked for the company for a long time. The Houston Police Department was notified.

3/1/01

"The truck and gauge were recovered and returned to the Licensee on 2/28/01. The gauge was still locked in the back of the truck; it was undamaged. A New Orleans, Louisiana resident noticed the truck parked in front of their residence and called the New Orleans Police Department. The Houston Police Department was notified and arranged the recovery.

"The Licensee will submit a written report providing additional details on 3/2/01."

Texas Incident #7726.