Event Notification Report for January 09, 2001

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
01/08/2001 - 01/09/2001

EVENT NUMBERS
376573765837704

Power Reactor
Event Number: 37657
Facility: DRESDEN
Region: 3     State: IL
Unit: [] [] [3]
RX Type: [1] GE-1,[2] GE-3,[3] GE-3
NRC Notified By: RUNION
HQ OPS Officer: FANGIE JONES
Notification Date: 01/09/2001
Notification Time: 08:13 [ET]
Event Date: 01/09/2001
Event Time: 04:01 [CST]
Last Update Date: 01/09/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iii)(C) - POT UNCNTRL RAD REL
Person (Organization):
JOHN JACOBSON (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N Y 100 Power Operation 100 Power Operation
Event Text
ISOLATION CONDENSER STEAM CONDENSATE HIGH FLOW SWITCHES OUT OF CALIBRATION

"During performance of DIS 1300-07, Isolation Condenser Steam Condensate High Flow Switch Calibration, DP switch 3-1349A as found trip setpoint was outside of T.S. limits. The as found value was -17.5 in WC and the T.S. limit is </= to 14.8 in WC. Later in the same surveillance, DP switch 3-1349B as found trip setpoint was outside of T.S. limit is </= 14.8 in WC. These are the Div 1 and Div 2 Isolation Condenser Condensate High Flow isolation instruments. With both these switches inop, the Isolation Condenser would not have isolated at the appropriate time on a valid high condensate flow signal. The Isolation Condenser was already isolated when the out of tolerance switches were discovered and the switches were calibrated satisfactorily prior to unisolating the Isolation Condenser."

The licensee notified the NRC Resident Inspector.


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 37658
Facility: PERRY
Region: 3     State: OH
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: ROBERT KIDDER
HQ OPS Officer: BOB STRANSKY
Notification Date: 01/09/2001
Notification Time: 13:08 [ET]
Event Date: 01/09/2001
Event Time: 12:20 [EST]
Last Update Date: 01/17/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
70.52(a) - LOSS OF SNM/CRIT 70.52(b) - LOSS OF SNM/FISSILE 73.71(b)(1) - SAFEGUARDS REPORTS
Person (Organization):
JOHN JACOBSON (R3)
ED GOODWIN (NRR)
FRITZ STURZ (NMSS)
JOSEPH GIITTER (IRO)
ROBERT SKELTON (IAT)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 87 Power Operation 87 Power Operation
Event Text
NEUTRON MONITORING DETECTOR MISSING FROM SHIPMENT

The licensee reported that one local power range monitor (LPRM) detector was missing out of a shipment from GE Reuter-Stokes in Twinsburg, OH. The missing detector contains 0.00027g of U-235 (0.00121g total U) in the form of solid uranium oxide. The licensee has contacted the vendor to determine whether an error occurred in preparation of the shipping papers. The NRC resident inspector will be informed of this event by the licensee.

* * * UPDATE 1529 FROM KIDDER TAKEN BY STRANSKY * * *

At 1355, the licensee was informed that the missing LPRM detector is currently located at the GE Reuter-Stokes facility and had not been shipped. The NRC resident inspector has been informed of this update. Notified R3DO (Jacobson).

* * * RETRACTION 1015 01/17/2001 FROM RUSSELL TAKEN BY STRANSKY * * *

"Investigation by the licensee and the manufacturer discovered that the LPRM had been maintained in a secure, locked area at GE Reuter-Stokes and had been kept under appropriate controls. Accordingly, no reporting criterion is applicable to this event under 10CFR50.72 or 10CFR70.52. Additionally, the SNM is not of sufficient quantity that 10CFR73.71(a)(1) or 10CFR20.2201 apply.

"Event Notification 37658 is therefore retracted."

The NRC resident inspector has been informed of this retraction by the licensee. Notified R3DO (Lanksbury).


Power Reactor
Event Number: 37704
Facility: SAINT LUCIE
Region: 2     State: FL
Unit: [] [2] []
RX Type: [1] CE,[2] CE
NRC Notified By: ALBRITTON
HQ OPS Officer: DOUG WEAVER
Notification Date: 01/31/2001
Notification Time: 15:08 [ET]
Event Date: 01/09/2001
Event Time: 09:30 [EST]
Last Update Date: 01/31/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
LEONARD WERT (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
POTENTIAL FOR THE CONTROL ROOM OPERATORS TO EXCEED GENERAL DESIGN CRITERIA 19 LIMITS DURING AN ACCIDENT

Following evaluation and analysis, FPL identified a condition that could have potentially led to the control room operators receiving a dose in excess of GDC 19 limits during accident conditions. St. Lucie recently identified weaknesses in the Unit 2 procedures that could result in the operators not taking action to manually align the control room outside air intakes to pressurize the control room when the control room ventilation system is operating in the emergency recirculation mode. The procedures direct which outside air intake should be used depending on existing radiological conditions. However, the procedures do not direct the operators to establish outside makeup air (i.e.. throttle open the outside air intake valves) if minimum control room pressurization is met. In addition to the procedural weaknesses identified, the control room differential pressure indicators exhibit a small positive pressure bias that could have misled the operators into believing that the control room was maintained at a positive differential pressure without the need to open the outside air intake valves. During the course of the hypothesized accident, operation of the control room ventilation system in this condition would have been ultimately discovered and corrected by the technical advisors in the Technical Support Center or Emergency Operations Facility.

St. Lucie issued Night Orders to the operating crews to clarify operational requirements for the control room ventilation systems until the requisite procedure changes are implemented.

The licensee notified the NRC resident inspector.