Event Notification Report for December 15, 2000
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
12/14/2000 - 12/15/2000
EVENT NUMBERS
37605376063764537773
General Information or Other
Event Number: 37605
Rep Org: WA DIVISION OF RADIATION PROTECTION
Licensee: NORTHWEST INSPECTION, INC.
Region: 4
City: PASCO State: WA
County:
License #: WN-IR065-1
Agreement: Y
Docket:
NRC Notified By: TERRY FRAZEE
HQ OPS Officer: FANGIE JONES
Licensee: NORTHWEST INSPECTION, INC.
Region: 4
City: PASCO State: WA
County:
License #: WN-IR065-1
Agreement: Y
Docket:
NRC Notified By: TERRY FRAZEE
HQ OPS Officer: FANGIE JONES
Notification Date: 12/15/2000
Notification Time: 19:25 [ET]
Event Date: 12/15/2000
Event Time: 00:00 [PST]
Last Update Date: 12/15/2000
Notification Time: 19:25 [ET]
Event Date: 12/15/2000
Event Time: 00:00 [PST]
Last Update Date: 12/15/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
CHUCK CAIN (R4)
JOHN GREEVES (NMSS)
CHUCK CAIN (R4)
JOHN GREEVES (NMSS)
AGREEMENT STATE REPORT
The following is taken from an e-mail report:
This is notification of an event in Washington state as investigated by the WA Department of Health, Division of Radiation Protection.
STATUS: new/closed
Licensee: NorthWest Inspection, Inc.
City and state: Richland, WA
License number: WN-IR065-1
Type of license: Industrial Radiography
Date of event: December 15, 2000
Location of Event: Pasco, WA
ABSTRACT: (where, when, how, why; cause, contributing factors, corrective actions, consequences, DOH on-site investigation; media attention) The building where the licensee stores its radiography equipment suffered a
major fire in the early morning of December 15, 2000. The building, constructed of concrete block walls with a wood/plywood type roof, is primarily occupied by the local Pipe Fitters Union which has offices, classrooms and a welding test area in the portion of the building that burned. The licensee's industrial radiography camera and a source changer were locked in a 3/8 inch steel, lead-lined, cabinet next to the concrete block wall. Because of the licensee's inability to take immediate protective actions necessary to avoid exposure to sources of radiation or releases of radioactive material that could exceed regulatory limits, the licensee immediately notified the department. For several hours the licensee was not permitted to enter the area to determine whether damage had occurred to his equipment which contains depleted uranium for shielding and one 35 curie Iridium-192 source. The licensee was not able to retrieve the equipment until the debris from the burned out roof was cleared that afternoon. Staff from the department was on-scene to survey the radiography
camera and source changer and take appropriate smears to check for contamination. No contamination was noted. The licensee secured the equipment in his truck (normal mode of transportation for these items) pending license amendment for a new storage location.
What is the notification or reporting criteria involved? WAC 246-221-250
Notification of incidents (Immediate notification)
Activity and Isotope(s) involved: 35 curies Ir-192; depleted uranium.
The following is taken from an e-mail report:
This is notification of an event in Washington state as investigated by the WA Department of Health, Division of Radiation Protection.
STATUS: new/closed
Licensee: NorthWest Inspection, Inc.
City and state: Richland, WA
License number: WN-IR065-1
Type of license: Industrial Radiography
Date of event: December 15, 2000
Location of Event: Pasco, WA
ABSTRACT: (where, when, how, why; cause, contributing factors, corrective actions, consequences, DOH on-site investigation; media attention) The building where the licensee stores its radiography equipment suffered a
major fire in the early morning of December 15, 2000. The building, constructed of concrete block walls with a wood/plywood type roof, is primarily occupied by the local Pipe Fitters Union which has offices, classrooms and a welding test area in the portion of the building that burned. The licensee's industrial radiography camera and a source changer were locked in a 3/8 inch steel, lead-lined, cabinet next to the concrete block wall. Because of the licensee's inability to take immediate protective actions necessary to avoid exposure to sources of radiation or releases of radioactive material that could exceed regulatory limits, the licensee immediately notified the department. For several hours the licensee was not permitted to enter the area to determine whether damage had occurred to his equipment which contains depleted uranium for shielding and one 35 curie Iridium-192 source. The licensee was not able to retrieve the equipment until the debris from the burned out roof was cleared that afternoon. Staff from the department was on-scene to survey the radiography
camera and source changer and take appropriate smears to check for contamination. No contamination was noted. The licensee secured the equipment in his truck (normal mode of transportation for these items) pending license amendment for a new storage location.
What is the notification or reporting criteria involved? WAC 246-221-250
Notification of incidents (Immediate notification)
Activity and Isotope(s) involved: 35 curies Ir-192; depleted uranium.
Fuel Cycle Facility
Event Number: 37606
Facility: PADUCAH GASEOUS DIFFUSION PLANT
Region: 3 State: KY
Unit: [] [] []
RX Type: URANIUM ENRICHMENT FACILITY
Comments: 2 DEMOCRACY CENTER
6903 ROCKLEDGE DRIVE
BETHESDA, MD 20817 (301)564-3200
NRC Notified By: K BEASLEY
HQ OPS Officer: FANGIE JONES
Region: 3 State: KY
Unit: [] [] []
RX Type: URANIUM ENRICHMENT FACILITY
Comments: 2 DEMOCRACY CENTER
6903 ROCKLEDGE DRIVE
BETHESDA, MD 20817 (301)564-3200
NRC Notified By: K BEASLEY
HQ OPS Officer: FANGIE JONES
Notification Date: 12/15/2000
Notification Time: 21:27 [ET]
Event Date: 12/15/2000
Event Time: 17:30 [CST]
Last Update Date: 12/15/2000
Notification Time: 21:27 [ET]
Event Date: 12/15/2000
Event Time: 17:30 [CST]
Last Update Date: 12/15/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
RONALD GARDNER (R3)
JOHN GREEVES (NMSS)
RONALD GARDNER (R3)
JOHN GREEVES (NMSS)
24 HOUR REPORT - SAFETY SYSTEM ACTUATION
"At 1730 on 12/15/00, the PSS office was notified that a primary condensate alarm was received on the C-337A position 3 East autoclave Water Inventory Control System (WICS). The WICS system is required to be operable while heating in mode 5 according to TSR 2.2.4.2. The autoclave was checked according to the alarm response procedure, removed from service and the Water Inventory Control System was declared inoperable by the Plant Shift Superintendent.
"This safety system actuation is reportable to the NRC as required by Safety Analysis Report, section 6.9, table 1, criteria J.2, Safety System actuation due to a valid signal as a 24-hour event notification.
"The NRC Senior Resident inspector has been notified of this event."
"At 1730 on 12/15/00, the PSS office was notified that a primary condensate alarm was received on the C-337A position 3 East autoclave Water Inventory Control System (WICS). The WICS system is required to be operable while heating in mode 5 according to TSR 2.2.4.2. The autoclave was checked according to the alarm response procedure, removed from service and the Water Inventory Control System was declared inoperable by the Plant Shift Superintendent.
"This safety system actuation is reportable to the NRC as required by Safety Analysis Report, section 6.9, table 1, criteria J.2, Safety System actuation due to a valid signal as a 24-hour event notification.
"The NRC Senior Resident inspector has been notified of this event."
General Information or Other
Event Number: 37645
Rep Org: CALIFORNIA RADIATION CONTROL PRGM
Licensee: ANCORE (SAIC)
Region: 4
City: SAN DIEGO State: CA
County:
License #: 2484-43
Agreement: Y
Docket:
NRC Notified By: ROB GREGER
HQ OPS Officer: JOHN MacKINNON
Licensee: ANCORE (SAIC)
Region: 4
City: SAN DIEGO State: CA
County:
License #: 2484-43
Agreement: Y
Docket:
NRC Notified By: ROB GREGER
HQ OPS Officer: JOHN MacKINNON
Notification Date: 01/04/2001
Notification Time: 12:01 [ET]
Event Date: 12/15/2000
Event Time: 12:00 [PST]
Last Update Date: 01/04/2001
Notification Time: 12:01 [ET]
Event Date: 12/15/2000
Event Time: 12:00 [PST]
Last Update Date: 01/04/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
WILLIAM JOHNSON (R4)
BRIAN SMITH (NMSS)
WILLIAM JOHNSON (R4)
BRIAN SMITH (NMSS)
AGREEMENT STATE REPORT
ANCORE (previously SAIC) had requested to delete three nuclides from their CA RML. One of the items ANCORE asked to be deleted were fuel rods containing SNM. A letter for additional information concerning transfer/disposal of the fuel rods went out on May 25, 2000 but received no response. Tom Schell contacted the current RSO, David Mahood. Mr. Mahood stated that the fuel rods were sent to Combustion Engineering before he came to ANCORE. Mr. Mahood further added that his questions to the previous RSO failed to produce any new information or documents concerning the fuel rods. Tom Schell also contacted Brian Horn of the US NRC and the US Nuclear Tracking Database confirms the transfer of the three fuel rods to SAIC in San Diego, a different California license, in September 1989. A review of the Compliance and Licensing Folders SAIC's San Diego License (License Number 2290-37) was done but independent confirmation relating to the receipt of fuel rods containing SNM at SAIC in San Diego were not found. A Note: California regulations only require record keeping for three years, however 10 CFR 150.16 appears to have been violated. Personnel of California Radiologic Health Branch were informed.
STATE OF CALIFORNIA REPORT NUMBER CA010003
ANCORE (previously SAIC) had requested to delete three nuclides from their CA RML. One of the items ANCORE asked to be deleted were fuel rods containing SNM. A letter for additional information concerning transfer/disposal of the fuel rods went out on May 25, 2000 but received no response. Tom Schell contacted the current RSO, David Mahood. Mr. Mahood stated that the fuel rods were sent to Combustion Engineering before he came to ANCORE. Mr. Mahood further added that his questions to the previous RSO failed to produce any new information or documents concerning the fuel rods. Tom Schell also contacted Brian Horn of the US NRC and the US Nuclear Tracking Database confirms the transfer of the three fuel rods to SAIC in San Diego, a different California license, in September 1989. A review of the Compliance and Licensing Folders SAIC's San Diego License (License Number 2290-37) was done but independent confirmation relating to the receipt of fuel rods containing SNM at SAIC in San Diego were not found. A Note: California regulations only require record keeping for three years, however 10 CFR 150.16 appears to have been violated. Personnel of California Radiologic Health Branch were informed.
STATE OF CALIFORNIA REPORT NUMBER CA010003
Other Nuclear Material
Event Number: 37773
Rep Org: U.S. ARMY
Licensee: U.S. ARMY
Region: 0
City: State:
County:
License #: 19-30653-01
Agreement: N
Docket:
NRC Notified By: JOYCE KUYKENDALL
HQ OPS Officer: JOHN MacKINNON
Licensee: U.S. ARMY
Region: 0
City: State:
County:
License #: 19-30653-01
Agreement: N
Docket:
NRC Notified By: JOYCE KUYKENDALL
HQ OPS Officer: JOHN MacKINNON
Notification Date: 02/23/2001
Notification Time: 13:16 [ET]
Event Date: 12/15/2000
Event Time: 12:00 [EST]
Last Update Date: 02/23/2001
Notification Time: 13:16 [ET]
Event Date: 12/15/2000
Event Time: 12:00 [EST]
Last Update Date: 02/23/2001
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X
10 CFR Section:
20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X
Person (Organization):
GLENN MEYER (R1)
MARK RING (R3)
BRIAN SMITH (NMSS)
GLENN MEYER (R1)
MARK RING (R3)
BRIAN SMITH (NMSS)
THREE CHEMICAL AGENT MONITORS FOUND MISSING DURING AN INVENTORY CHECK.
During an inventory check on 12/15/2000 by the First Signal Brigade Unit located in Yongsan, Korea, it was discovered that 3 chemical agent monitors each containing 15mCi's of Nickel-63 were found missing. An investigation into the loss of the three chemical agent monitors was initiated.
During an inventory check on 12/15/2000 by the First Signal Brigade Unit located in Yongsan, Korea, it was discovered that 3 chemical agent monitors each containing 15mCi's of Nickel-63 were found missing. An investigation into the loss of the three chemical agent monitors was initiated.