Skip to main content

Event Notification Report for December 01, 2000

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
11/30/2000 - 12/01/2000

EVENT NUMBERS
3756537560375613756237563

General Information or Other
Event Number: 37565
Rep Org: ILLINOIS DEPT OF NUCLEAR SAFETY
Licensee: ILLINOIS DEPT OF NUCLEAR SAFETY
Region: 3
City: ROCKFORD   State: IL
County:
License #:
Agreement: Y
Docket:
NRC Notified By: JOE KLINGER
HQ OPS Officer: JOHN MacKINNON
Notification Date: 12/04/2000
Notification Time: 17:06 [ET]
Event Date: 12/01/2000
Event Time: 10:00 [CST]
Last Update Date: 12/04/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
MICHAEL PARKER (R3)
LARRY CAMPER (NMSS)
Event Text
BARE UNMARKED 8 MILLICURIE CESIUM-137 SOURCE FOUND IN SCRAPYARD.

On December 01, 2000, around 1000 CT the Illinois Department of Nuclear Safety was notified by Joseph Behr Metals, Inc., that a bare 8 millicurie Cesium-137 source had been discovered after their truck portal monitor had alarmed. Illinois Department of Nuclear Safety immediately sent personnel to the site. The area around the Cesium-137 was secured and the source was leak tested, doubled bagged, labeled, and locked in a secure facility at the site by Illinois Department of Nuclear Safety personnel. Joseph Behr Metals, Inc., will have the source properly disposed of in the very near future.

The source is unmarked and it looks like it has been through a shredder and nobody came in contact with or was exposed to the source. The source appears to have belonged to a Moisture Density gauge.

The Illinois Department of Nuclear Safety has placed the 8 millicurie Cesium-137 on their orphan source list.


Power Reactor
Event Number: 37560
Facility: FT CALHOUN
Region: 4     State: NE
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: ANTHONY CHRISTIANSON
HQ OPS Officer: BOB STRANSKY
Notification Date: 12/01/2000
Notification Time: 07:30 [ET]
Event Date: 12/01/2000
Event Time: 05:40 [CST]
Last Update Date: 12/01/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(i)(A) - PLANT S/D REQD BY TS
Person (Organization):
KRISS KENNEDY (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
PLANT SHUTDOWN REQUIRED DUE TO TECHNICAL SPECIFICATIONS

The licensee reported that the unit has commenced a shutdown in accordance with Technical Specification 2.1.4 due to an approximately 1 gpm reactor coolant system (RCS) leak. The licensee stated that the leakage, as measured by containment sump level, began suddenly this morning and increased to the TS 2.1.4 threshold of 1 gpm. (The criterion for declaration of an Unusual Event is 10 gpm.) The licensee is preparing to make a containment entry in order to identify the location of the leak.

The NRC resident inspector has been informed of this event by the licensee.

* * * UPDATE ON 12/01/00 AT 1540 ET BY ERICK MATZKE TAKEN BY MACKINNON * * *

The leak has been identified and isolated, CVCS system isolated. The leak is located on a socket weld to the CVCS Regenerative Heat Exchanger. The crack on the socket weld is approximately 1.24" in length. The licensee has an alternate charging path to the reactor coolant system. Technical Specification 2.1.4 was exited at 0830 CST and the shutdown of the plant was secured at about 0900 CST. Reactor power is about 86%. Options for repair of the leak are being investigated at this time. R4DO (Kriss Kennedy) notified.

The NRC Resident Inspector was notified of this event update by the licensee.


Power Reactor
Event Number: 37561
Facility: DRESDEN
Region: 3     State: IL
Unit: [] [2] []
RX Type: [1] GE-1,[2] GE-3,[3] GE-3
NRC Notified By: VERCELLI
HQ OPS Officer: JOHN MacKINNON
Notification Date: 12/01/2000
Notification Time: 12:46 [ET]
Event Date: 12/01/2000
Event Time: 10:15 [CST]
Last Update Date: 12/01/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iii)(B) - POT RHR INOP
Person (Organization):
MICHAEL JORDAN (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Hot Shutdown 0 Hot Shutdown
Event Text
DISCOVERED THAT SHUTDOWN COOLING SYSTEM COULD NOT BE PLACED IN SERVICE.

Logic for Shutdown Cooling System would have prevented placing Shutdown Cooling in service (not currently required to be in service because Shutdown cooling is above its cut in permissive temperature of 350 degrees F). A component had high resistance simulating a high temperature condition (thermocouples failed high). Maintenance is troubleshooting the problem at this time.

At the this time rods are being pulled to go critical.

The NRC Resident Inspector was notified of this event by the licensee.


Power Reactor
Event Number: 37562
Facility: LASALLE
Region: 3     State: IL
Unit: [] [2] []
RX Type: [1] GE-5,[2] GE-5
NRC Notified By: AL BAILEY
HQ OPS Officer: JOHN MacKINNON
Notification Date: 12/01/2000
Notification Time: 14:34 [ET]
Event Date: 12/01/2000
Event Time: 11:10 [CST]
Last Update Date: 12/01/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - RPS ACTUATION
Person (Organization):
MICHAEL JORDAN (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 A/R Y 30 Power Operation 0 Hot Shutdown
Event Text
AUTOMATIC REACTOR SCRAM OF DUE TO HIGH REACTOR VESSEL WATER LEVEL.

High reactor vessel water level occurred during feedwater manipulations to place "2B" Turbine Driven Reactor Feedwater Pump online. The abnormally high reactor vessel water level (level 8) initiated trips of the Main Generator and all online feedwater pumps, resulting in a reactor scram. All rods fully inserted into the core. Reactor vessel water level has been restored to a normal level of 36 inches using their Motor Driven Reactor Feedwater Pump. All equipment responded as expected. There were no ESF actuations because of this event. Conditions are stable. An investigation has been initiated to determine the cause of the abnormally high reactor vessel water level. The licensee was coming out of a refueling outage when the reactor scrammed from 30% reactor power due to the valid high reactor vessel water level signal.

The NRC Resident Inspector was notified of this event by the licensee.


Power Reactor
Event Number: 37563
Facility: DAVIS BESSE
Region: 3     State: OH
Unit: [1] [] []
RX Type: [1] B&W-R-LP
NRC Notified By: DOUG WHALEN
HQ OPS Officer: JOHN MacKINNON
Notification Date: 12/01/2000
Notification Time: 15:46 [ET]
Event Date: 12/01/2000
Event Time: 14:50 [EST]
Last Update Date: 12/01/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
73.71(b)(1) - SAFEGUARDS REPORTS
Person (Organization):
MICHAEL JORDAN (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
UNESCORTED ACCESS GRANTED INAPPROPRIATELY TO A CONTRACTOR. IMMEDIATE COMPENSATORY MEASURES TAKEN UPON DISCOVERY.

The NRC Resident Inspector was notified of this event by the licensee.

See HOO Log Book for further details.